Geometric distortion of digital angiography image

被引:0
|
作者
Lei, TH
Simard, JM
Sewchand, W
Mathis, JM
机构
关键词
digital angiography; geometric distortion; image fusion; cursor projection;
D O I
10.1117/12.273990
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Digital angiography remains valuable in a diagnostic environment where anatomical definition is important. However it is not sufficiently reliable in circumstances (such as stereotactic application) where precise geometry is important. The geometric distortion of digital angiography is mainly caused by the inherent, non-uniform electromagnetic field of the Image Intensifier board. In this paper we quantify this distortion so as to evaluate its clinical relevance. We utilize image fusion with fiducial markers and image exploration with cursor projection in this investigation. Fiducial markers on the images were normalized first and then used as baselines to scale and orient the corresponding images so they could be accurately registered, superimposed, and subtracted. Image exploration with cursor projection allowed for easy identification of the same point on corresponding images, which provided quantitative evaluation of geometric differences between digital and analogue angiography images. Based on our study, we concluded: 1) Compared with MRI geometric distortion of as much as 2 mm, digital angiography is clinically appropriate for stereotactic application; 2) With an improved test object (reducing the vertical and horizontal lines which form the square grids from the current thickness of 0.8 mm), the results would be more accurate.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 50 条
  • [1] A Method on Digital Watermarking Image against Geometric Distortion
    Lin, Ziyan
    Niu, Lipi
    Jiang, Xiuhua
    2014 7TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP 2014), 2014, : 130 - 134
  • [2] A robust watermarking technique in geometric distortion of digital image
    Kim, W
    Ko, IJ
    Lee, NY
    Kim, GY
    Choi, HI
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2003, PT 2, PROCEEDINGS, 2003, 2668 : 310 - 319
  • [3] Image distortion correction of digital subtraction angiography in stereotactic radiosurgery
    Hoevels, M
    Treuer, H
    Thesen, N
    Landwehr, P
    Heindel, W
    Muller, RP
    Sturm, V
    CAR '96: COMPUTER ASSISTED RADIOLOGY, 1996, 1124 : 998 - 998
  • [4] Comparison of geometric distortion in digital angiography with and without a correction program -: Technical note
    Zheng, Z
    Shearer, D
    Norén, G
    Chougule, P
    Friehs, G
    JOURNAL OF NEUROSURGERY, 2000, 93 : 223 - 227
  • [5] The accuracy and reproducibility of an algorithm to correct for geometric image distortion in quantitative coronary angiography
    Gronenschild, E
    Roos, J
    Mulkens, G
    COMPUTERS IN CARDIOLOGY 1996, 1996, : 105 - 108
  • [6] Geometric Distortion Correction to Testing Image
    Zhang, Fangzhou
    Zuo, Xiaoyan
    Liu, Jiafa
    Wu, Xiaoyu
    Wang, Yan
    PIAGENG 2009: IMAGE PROCESSING AND PHOTONICS FOR AGRICULTURAL ENGINEERING, 2009, 7489
  • [7] Geometric calibration of a digital angiography team
    Ramirez, J. M.
    Medina, R.
    Garreau, Mireille
    IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 381 - +
  • [8] Technical Note: Correction of geometric x-ray image intensifier distortion based on digital image correlation
    Sanctorum, Joaquim
    Van Wassenbergh, Sam
    Aerts, Peter
    Dirckx, Joris
    MEDICAL PHYSICS, 2020, 47 (02) : 597 - 603
  • [9] A method of identifying digital images with geometric distortion
    Hwang, Min Gu
    Kim, Sung Min
    Har, Dong Hwan
    Australian Journal of Forensic Sciences, 2017, 49 (01) : 93 - 105
  • [10] An image watermarking algorithm robust to geometric distortion
    Kang, XG
    Huang, JW
    Shi, YQ
    DIGITAL WATERMARKING, 2002, 2613 : 212 - 223