Spatial over-sampling and its influence on spatial resolution for photoacoustic tomography with finite sized detectors

被引:0
|
作者
Burgholzer, P. [1 ]
Roitner, H. [1 ]
Berer, T. [1 ]
Gruen, H. [1 ]
Nuster, R. [2 ]
Paltauf, G. [2 ]
Haltmeier, M. [3 ]
机构
[1] Res Ctr Non Destruct Testing GmbH, RECENDT, Linz, Austria
[2] BKarl Franzens Univ, Dept Phys, Graz, Austria
[3] Leopold Franzens Univ, Dept Math, Innsbruck, Austria
基金
奥地利科学基金会;
关键词
Photoacoustic tomography; optoacoustic; thermoacoustic; blurring; finite detector size; integrating detector; reconstruction; deconvolution; deblurring;
D O I
10.1117/12.2039591
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Detector arrays enable parallel detection for faster photoacoustic imaging than by moving a single detector, but the detector spacing for arrays cannot be smaller than the size of an array element. Spatial over-sampling is scanning with a step-size smaller than the size of the detector element and is possible only for a moving single detector. For a detector with finite sized surface the measured acoustic signal is a spatial average of the pressure field over the detector surface. If the reconstruction is performed assuming point-like detection over-sampling brings no advantage as e. g. for spherical or cylindrical detection surfaces the blurring caused by a finite detector size is proportional to the distance from the rotation center and is equal to the detector size at the detection surface. Iterative reconstruction algorithms or inverting directly the imaging matrix can take the finite size of real detectors directly into account, but the numerical effort is significantly higher compared to direct algorithms assuming point-like detection. Another reconstruction with less numerical effort is to use a direct algorithm assuming point-like detectors and run a deconvolution algorithm for deblurring afterwards. For such reconstruction methods spatial over-sampling makes sense because it reduces the blurring significantly. The effect of step size on the reconstructed image is systematically examined using simulated and experimental data. Experimental data are obtained on a plastisol cylinder with thin holes filled with an absorbing liquid. Data acquisition is done by utilization of a piezoelectric detector (PVDF stripe) which is rotated around the plastisol cylinder.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Spatial resolution in photoacoustic computed tomography
    Tian, Chao
    Zhang, Chenxi
    Zhang, Haoran
    Xie, Dan
    Jin, Yi
    REPORTS ON PROGRESS IN PHYSICS, 2021, 84 (03)
  • [2] Reconstruction of photoacoustic tomography with finite-aperture detectors: deconvolution of the spatial impulse response
    Li, Meng-Lin
    Cheng, Chung-Chih
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [3] Deconvolution algorithms for photoacoustic tomography to reduce blurring caused by finite sized detectors
    Burgholzer, P.
    Roitner, H.
    Berer, T.
    Gruen, H.
    O'Leary, D. P.
    Nuster, R.
    Paltauf, G.
    Haltmeier, M.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013, 2013, 8581
  • [4] Spatial resolution and sensitivity in photoacoustic tomography taking noise into account: from point-like detectors to large integrating detectors
    Burgholzer, P.
    Berer, T.
    Gruen, H.
    Nuster, R.
    Paltauf, G.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223
  • [5] Point target detection based on Temporal-Spatial Over-Sampling system
    Wang Shi-Tao
    Zhang Wei
    Jin Li-Hua
    Hou Qing-Yu
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2013, 32 (01) : 68 - 72
  • [6] Noise Reduction with Over-Sampling for High Resolution Detectors Using a Spread Function Convolution Method
    Shankar, A.
    Rana, R.
    Vijayan, S.
    Nagesh, S. V. Setlur
    Ionita, C.
    Bednarek, D.
    Rudin, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3252 - 3252
  • [7] Spatial resolution in photoacoustic tomography: effects of detector size and detector bandwidth
    Haltmeier, Markus
    Zangerl, Gerhard
    INVERSE PROBLEMS, 2010, 26 (12)
  • [8] Point target enhancement based on temporal-spatial over-sampling and image filtering
    Jin Ting
    Wang Humei
    Dong Xiaomeng
    Gao Hongxia
    Wang Shitao
    INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGE PROCESSING AND PATTERN RECOGNITION, 2014, 9301
  • [9] Spatial Resolution Enhancement in Integration-Mode Detectors for Proton Radiography and Tomography
    Gianoli, C.
    Meyer, S.
    Magallanes, L.
    Dedes, G.
    Landry, G.
    Nijhuis, R.
    Ganswindt, U.
    Thieke, C.
    Belka, C.
    Parodi, K.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S46 - S47
  • [10] Influence of backscattering on the spatial resolution of semiconductor X-ray detectors
    Hoheisel, M
    Korn, A
    Giersch, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 252 - 257