Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum

被引:68
|
作者
van den Ouweland, Johannes M. W. [1 ]
Beijers, Antonius M. [1 ]
van Daal, Henny [1 ]
机构
[1] Canisius Wilhelmina Hosp, Dept Clin Chem, NL-6532 SZ Nijmegen, Netherlands
关键词
C-3-epimer; 3-epi-25-hydroxyvitamin D-3; 25-hydroxyvitamin D; LC-MS/MS; MS response factor; Ionisation behaviour; TANDEM MASS-SPECTROMETRY; C-3; EPIMER; D-3; INFANTS; ADULTS; ACCOUNT;
D O I
10.1016/j.jchromb.2014.07.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: An LC-MS/MS method was developed for simultaneous quantification of 25-hydroxyvitamin D-3 (25(OH)D-3), 3-epi-25(OH)D-3, and 25(OH)D-2 in human serum. Methods: Sample preparation consisted of protein precipitation followed by off-line SPE. Calibration curves for each vitamin D metabolite were constructed in phosphate-buffered saline with 60 g/L albumin including its corresponding stable isotope labelled (SIL) internal standard. A pentafluorophenyl (PFP) analytical column was used to resolve 25(OH)D-3 from 25(OH)D-2 and 3-epi-25(OH)D-3, followed by SRM registration using positive ESI-MS/MS. Accuracy was assessed from measurement of samples with NIST reference method procedure (RMP) assigned values. The PFP LC-MS/MS method was compared to an in-house C-18 column LC-MS/MS method, not resolving 25(OH)D-3 from 3-epi-25(OH)D-3, using adult and newborn samples. Results: Intra-assay and inter-assay coefficients of variation were less than 4% and 7.5%, respectively for all three vitamin D metabolites; lower limits of quantification were 1, 1 and 2 nmol/L and linearity of methods were 1-500, 1-200 and 2-500 nmol/L for 25(OH)D-3, 3-epi-25(OH)D-3 and 25(OH)D-2, respectively. The PFP LC-MS/MS method showed minimal bias to the NIST RMP. Method comparison revealed that in the C-18 LC-MS/MS method, the 3-epi-25(OH)D-3 concentration is overestimated inadvertently not only from co-elution of both analytes, but also by an additional 30-40% higher ionisation efficiency of 3-epi-25(OH)D-3 when compared to 25(OH)D-3. Conclusion: This accurate LC-MS/MS method allows the simultaneous measurement of 25(OH)D-3, 3-epi-25(OH)D-3, and 25(OH)D-2 in human serum. Due to increased ionisation efficiency, the contribution of the 3-epi-25(OH)D-3 metabolite to the total 25(OH)D-3 concentration is significantly overestimated in MS methods that do not resolve 3-epi-25(OH)D-3 from 25(OH)D-3 and may compromise its use in infant samples known to have significant amounts of 3-epi-25(OH)D-3. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 50 条
  • [1] Measurement of plasma 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in population of patients with cardiovascular disease by UPLC-MS/MS method
    Abouzid, Mohamed
    Karazniewicz-Lada, Marta
    Pawlak, Kornel
    Burchardt, Pawel
    Kruszyna, Lukasz
    Glowka, Franciszek
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
  • [2] Enhanced 3-epi-25-hydroxyvitamin D3 signal leads to overestimation of its concentration and amplifies interference in 25-hydroxyvitamin D LC-MS/MS assays
    Flynn, N.
    Lam, F.
    Dawnay, A.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2014, 51 (03) : 352 - 359
  • [3] Preanalytical evaluation of serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 measurements using LC-MS/MS
    Mochizuki, Asuka
    Kodera, Yoshio
    Saito, Tatsuya
    Satoh, Mamotu
    Sogawa, Kazuyuki
    Nishimura, Motoi
    Seimiya, Masanori
    Kubota, Masayuki
    Nomura, Fumio
    CLINICA CHIMICA ACTA, 2013, 420 : 114 - 120
  • [4] Development and optimization of an LC-MS/MS-based method for simultaneous quantification of vitamin D2, vitamin D3, 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3
    Adamec, Jiri
    Jannasch, Amber
    Huang, Jianjie
    Hohman, Emily
    Fleet, James C.
    Peacock, Munro
    Ferruzzi, Mario G.
    Martin, Berdine
    Weaver, Connie M.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) : 11 - 20
  • [5] A specific LC/ESI-MS/MS method for determination of 25-hydroxyvitamin D3 in neonatal dried blood spots containing a potential interfering metabolite, 3-epi-25-hydroxyvitamin D3
    Higashi, Tatsuya
    Suzuki, Masahiro
    Hanai, Junji
    Inagaki, Shinsuke
    Min, Jun Zhe
    Shimada, Kazutake
    Toyo'oka, Toshimasa
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (07) : 725 - 732
  • [6] A simple and sensitive LC-MS/MS method for measuring serum 25-hydroxyvitamin D2 and D3
    Chan, Y. M.
    Stiess, K.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A113 - A113
  • [7] 25-Hydroxyvitamin D2/D3 Analysis in Human Plasma Using LC-MS
    Koerner, Phil
    McGinley, Michael
    LC GC NORTH AMERICA, 2011, : 70 - 73
  • [8] 25-Hydroxyvitamin D2/D3 Analysis in Human Plasma Using LC-MS
    Koerner, Phil
    McGinley, Michael
    LC GC NORTH AMERICA, 2011, : 8 - 11
  • [9] Simultaneous quantification of vitamin D3, 25-hydroxyvitamin D3 and 24,25-dihydroxyvitamin D3 in human serum by LC-MS/MS
    Burild, Anders
    Frandsen, Henrik L.
    Jakobsen, Jette
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2014, 74 (05): : 418 - 423
  • [10] Fast Separation of 25-Hydroxyvitamin D3 from 3-Epi-25-Hydroxyvitamin D3 in Human Serum by Liquid Chromatography-Tandem Mass Spectrometry: Variable Prevalence of 3-Epi-25-Hydroxyvitamin D3 in Infants, Children, and Adults
    van den Ouweland, Johannes M. W.
    Beijers, Antonius M.
    van Daal, Henny
    CLINICAL CHEMISTRY, 2011, 57 (11) : 1618 - 1619