Micromechanical evaluation of cortical bone using in situ XCT indentation and digital volume correlation

被引:15
|
作者
Karali, Aikaterina [1 ]
Kao, Alexander P. [3 ]
Zekonyte, Jurgita [1 ]
Blunn, Gordon [2 ]
Tozzi, Gianluca [1 ]
机构
[1] Univ Portsmouth, Zeiss Global Ctr, Sch Mech & Design Engn, Portsmouth, Hants, England
[2] Univ Portsmouth, Sch Pharm & Biomed Sci, Portsmouth, Hants, England
[3] Elettra Sincrotrone Trieste SCpA, Trieste, Italy
关键词
X-ray computed tomography (XCT); In situ mechanics; Digital volume correlation (DVC); Cortical bone;
D O I
10.1016/j.jmbbm.2020.104298
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The overall mechanical behaviour of cortical bone is strongly dependant on its microstructure. X-ray computed tomography (XCT) has been widely used to identify the microstructural morphology of cortical tissue (i.e. pore network, Haversian and Volkmann's canals). However, the connection between microstructure and mechanics of cortical bone during plastic deformation is unclear. Hence, the purpose of this study is to provide an in-depth evaluation of the interplay of plastic strain building up in relation to changes in the canal network for cortical bone tissue. In situ step-wise XCT indentation was used to introduce a localised load on the surface of the tissue and digital volume correlation (DVC) was employed to assess the three-dimensional (3D) full-field plastic strain distribution in proximity of the indent. It was observed that regions adjacent to the imprint were under tensile strain, whereas the volume underneath experienced compressive strain. Canal loss and disruption was detected in regions of higher compressive strains exceeding -20000 mu epsilon and crack formation occurred in specimens where Haversian canals were running parallel to the indentation tip. The results of this study outline the relationship between the micromechanical and structural behaviour of cortical bone during plastic deformation, providing information on cortical tissue fracture pathways.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Probing Constitutive Models of Bohus Granite with In Situ Spherical Indentation and Digital Volume Correlation
    Shariati, H.
    Bouterf, A.
    Saadati, M.
    Larsson, P-L
    Hild, F.
    ROCK MECHANICS AND ROCK ENGINEERING, 2022, 55 (12) : 7369 - 7386
  • [2] Probing Constitutive Models of Bohus Granite with In Situ Spherical Indentation and Digital Volume Correlation
    H. Shariati
    A. Bouterf
    M. Saadati
    P.-L. Larsson
    F. Hild
    Rock Mechanics and Rock Engineering, 2022, 55 : 7369 - 7386
  • [3] Effect of radiation-induced damage of trabecular bone tissue evaluated using indentation and digital volume correlation
    Karali, Aikaterina
    Dall 'Ara, Enrico
    Zekonyte, Jurgita
    Kao, Alexander P.
    Blunn, Gordon
    Tozzi, Gianluca
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 138
  • [4] Characterization of the bone-metal implant interface by Digital Volume Correlation of in-situ loading using neutron tomography
    Le Cann, Sophie
    Tudisco, Erika
    Perdikouri, Christina
    Belfrage, Ola
    Kaestner, Anders
    Hall, Stephen
    Tagil, Magnus
    Isaksson, Hanna
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 75 : 271 - 278
  • [5] Time-resolved in situ synchrotron-microCT: 4D deformation of bone and bone analogues using digital volume correlation
    Fernandez, Marta Pena
    Kao, Alexander P.
    Bonithon, Roxane
    Howells, David
    Bodey, Andrew J.
    Wanelik, Kazimir
    Witte, Frank
    Johnston, Richard
    Arora, Hari
    Tozzi, Gianluca
    ACTA BIOMATERIALIA, 2021, 131 : 424 - 439
  • [6] Expanded digital volume correlation for ex situ applications
    Wan, Keshu
    Yang, Peng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (09)
  • [7] Effect of SR-microCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation
    Fernandez, Marta Peiia
    Cipiccia, Silvia
    Dall'Ara, Enrico
    Bodey, Andrew J.
    Parwani, Rachna
    Pani, Martino
    Blunn, Gordon W.
    Barber, Asa H.
    Tozzi, Gianluca
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 88 : 109 - 119
  • [8] In-Situ Systematic Error Correction for Digital Volume Correlation Using a Reference Sample
    Wang, B.
    Pan, B.
    Lubineau, G.
    EXPERIMENTAL MECHANICS, 2018, 58 (03) : 427 - 436
  • [9] In-Situ Systematic Error Correction for Digital Volume Correlation Using a Reference Sample
    B. Wang
    B. Pan
    G. Lubineau
    Experimental Mechanics, 2018, 58 : 427 - 436
  • [10] Respective roles of organic and mineral components of human cortical bone matrix in micromechanical behavior: An instrumented indentation study
    Bala, Y.
    Depalle, B.
    Douillard, T.
    Meille, S.
    Clement, P.
    Follet, H.
    Chevalier, J.
    Boivin, G.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (07) : 1473 - 1482