Evaluation of Plastic Scintillator Detector for Small Field Stereotactic Patient-Specific Quality Assurance

被引:0
|
作者
Qin, Y.
Gardner, S.
Huang, Y.
Kim, J.
Wen, N.
Chetty, I.
机构
关键词
D O I
10.1118/1.4957043
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SUGTEP208
引用
收藏
页码:3664 / 3664
页数:1
相关论文
共 50 条
  • [1] Technical Note: Evaluation of plastic scintillator detector for small field stereotactic patient-specific quality assurance
    Qin, Yujiao
    Gardner, Stephen J.
    Kim, Joshua
    Huang, Yimei
    Wen, Ning
    Doemer, Anthony
    Chetty, Indrin J.
    MEDICAL PHYSICS, 2017, 44 (10) : 5509 - 5516
  • [2] Use of a plastic scintillator detector for patient-specific quality assurance of VMAT SRS
    Snyder, Jesse D.
    Sullivan, Rodney J.
    Wu, Xingen
    Covington, Elizabeth L.
    Popple, Richard A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09): : 143 - 148
  • [3] Evaluation of a Prototype Plastic Scintillator Detector for Patient-Specific QA of Volumetric Modulated Arc Stereotactic Radiosurgery Plans
    Snyder, J.
    Popple, R.
    Wu, X.
    MEDICAL PHYSICS, 2017, 44 (06) : 3273 - 3273
  • [4] Patient-specific quality assurance for spot scanning proton beams using a large-volume liquid scintillator detector
    Robertson, D.
    Beddar, S.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [5] Evaluation of Patient-Specific Quality Assurance Based On Different Methods
    Yang, T.
    Qu, B.
    Dai, X.
    Xie, C.
    Xiaoshen, W.
    Cong, X.
    Wang, J.
    Xu, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2896 - 2896
  • [6] Tornotherapy patient-specific quality assurance
    Chaudhari, S.
    Goddu, S.
    Mutic, S.
    Grigsby, J.
    Low, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2498 - 2499
  • [7] Evaluation of a Phantom for Patient-specific Quality Assurance in the MR Linac
    Baumgartl, M.
    Safarkhanlo, Y.
    Ehrbar, S.
    Wilke, L.
    Krayenbuhl, J.
    Chamberlain, M.
    Zamburlini, M.
    Guckenberger, M.
    Andratschke, N.
    Tanadini-Lang, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (SUPPL 1) : S33 - S34
  • [8] Evaluation of Patient-Specific Quality Assurance Based On Different Methods
    Lin, X.
    Sun, T.
    Liu, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E211 - E211
  • [9] Automated patient-specific IMRT quality assurance using exit detector data
    Seibert, R.
    Ramsey, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2168 - 2168
  • [10] Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance
    Narayanasamy, Ganesh
    Zalman, Travis
    Ha, Chul S.
    Papanikolaou, Niko
    Stathakis, Sotirios
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 329 - 338