Placement of endovascular stent-grafts for emergency treatment of acute disease of the descending thoracic aorta

被引:66
|
作者
Czermak, BV
Waldenberger, P
Perkmann, R
Rieger, M
Steingruber, IE
Mallouhi, A
Fraedrich, G
Jaschke, WR
机构
[1] Leopold Franzens Med Sch, Kurt Amplatz Ctr, A-6020 Innsbruck, Austria
[2] Univ Innsbruck Hosp, A-6020 Innsbruck, Austria
[3] Leopold Franzens Med Sch, Dept Vasc Surg, A-6020 Innsbruck, Austria
关键词
D O I
10.2214/ajr.179.2.1790337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of this study was to evaluate the feasibility, safety, and effectiveness of endovascular stent-graft placement for the emergency treatment of acute descending thoracic aortic disease. MATERIALS AND METHODS. From January 1996 through November 2001, 18 patients underwent emergency endovascular stent-graft placement for various types of acute descending thoracic aortic disease. Five patients had Stanford type B aortic dissection, six had traumatic ruptures of the thoracic aorta, five had ruptured aortic aneurysms, and two had penetrating atherosclerotic aortic ulcers. All patients presented with life-threatening symptoms requiring treatment with stent-grafts from the emergency kit. All were at high surgical risk due to serious comorbidities. The efficacy of the procedure was assessed at follow-up studies before discharge and at 3, 6, and 12 months after intervention and yearly thereafter. RESULTS. The primary technical success rate was 78%. Four patients had primary perigraft leaks. The secondary technical success rate was 83%. One patient died 20 hr after intervention from stent-graft-related causes. Follow-up studies revealed stent-graft migration in one patient. Progression of disease was observed in one patient treated for dissection and in both patients treated for penetrating ulcers. One patient died 7 months after intervention of unknown reasons; all other patients are alive. The mean follow-up time was 17.4 months (range, 0-38 months). CONCLUSION. Emergency repair of acute descending thoracic aortic disease with stent-graft placement can be successfully accomplished and may be a promising alternative to open-chest surgery, especially in patients at high risk.
引用
收藏
页码:337 / 345
页数:9
相关论文
共 50 条
  • [1] Emergency treatment of acute rupture of the descending thoracic aorta using endovascular stent-grafts
    Amabile, Philippe
    Rollet, Gilles
    Vidal, Vincent
    Collart, Frederic
    Bartoli, Jean-Michel
    Piquet, Philippe
    ANNALS OF VASCULAR SURGERY, 2006, 20 (06) : 723 - 730
  • [2] Acute rupture of the descending thoracic aorta: Repair with use of endovascular stent-grafts
    Semba, CP
    Kato, N
    Kee, ST
    Lee, GK
    Mitchell, RS
    Miller, DC
    Dake, MD
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (03) : 337 - 342
  • [3] Transluminal placement of endovascular stent-grafts for the treatment of type A aortic dissection with an entry tear in the descending thoracic aorta
    Kato, N
    Shimono, T
    Hirano, T
    Ishida, M
    Yada, I
    Takeda, K
    JOURNAL OF VASCULAR SURGERY, 2001, 34 (06) : 1023 - 1028
  • [4] Transluminal placement of endovascular stent-grafts for the treatment of type A aortic dissection with an entry tear in the descending thoracic aorta
    Kato, N
    Shimono, T
    Hirano, T
    Kawaguchi, T
    Yada, I
    Takeda, K
    RADIOLOGY, 2000, 217 : 379 - 380
  • [5] Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic dissection or aneurysm
    Shim, WH
    Lee, DH
    Yoon, YS
    Lee, DY
    Cho, SY
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (6A): : 43P - 44P
  • [6] TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS
    DAKE, MD
    MILLER, DC
    SEMBA, CP
    MITCHELL, RS
    WALKER, PJ
    LIDDELL, RP
    NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26): : 1729 - 1734
  • [7] The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta
    Dake, MD
    Miller, DC
    Mitchell, RS
    Semba, CP
    Moore, KA
    Sakai, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (05): : 689 - 703
  • [8] Acute and contained rupture of the descending thoracic aorta: Treatment with endovascular stent grafts
    Kato, N
    Hirano, T
    Ishida, M
    Shimono, T
    Cheng, SH
    Yada, I
    Takeda, K
    JOURNAL OF VASCULAR SURGERY, 2003, 37 (01) : 100 - 105
  • [9] Endografts (or stent-grafts) and diseases of the descending thoracic aorta
    Rousseau, H.
    Marcheix, B.
    Chabbert, V.
    Dambrin, C.
    Cron, C.
    Leobon, B.
    Conil, C.
    Massabuau, P.
    Otal, P.
    Joffre, F.
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2006, 99 (12): : 1215 - 1224
  • [10] The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta - Discussion
    Griepp, RB
    Miller
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (05): : 703 - 704