Multi-scale, multi-modal analysis uncovers complex relationship at the brain tissue-implant neural interface: new emphasis on the biological interface

被引:96
|
作者
Michelson, Nicholas J. [1 ]
Vazquez, Alberto L. [1 ,2 ,3 ,4 ]
Eles, James R. [1 ,3 ]
Salatino, Joseph W. [5 ]
Purcell, Erin K. [5 ]
Williams, Jordan J. [6 ]
Cui, X. Tracy [1 ,3 ,7 ]
Kozai, Takashi D. Y. [1 ,3 ,4 ,7 ,8 ]
机构
[1] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15260 USA
[3] Univ Pittsburgh, Ctr Neural Basis Cognit, Pittsburgh, PA 15260 USA
[4] Univ Pittsburgh, Ctr Neurosci, Pittsburgh, PA 15260 USA
[5] Michigan State Univ, Dept Biomed Engn, E Lansing, MI 48824 USA
[6] Univ Pittsburgh, Dept Neurobiol, Pittsburgh, PA USA
[7] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15260 USA
[8] Univ Pittsburgh, NeuroTech Ctr, Brain Inst, Pittsburgh, PA 15260 USA
关键词
intracortical microelectrode arrays; molecular and cellular neurobiology; foreign body response; brain-computer interface; biocompatibility; biotic and abiotic failure; NEUROINFLAMMATORY RESPONSE; MOLECULAR-MECHANISMS; ELECTRODE ARRAY; CEREBRAL-CORTEX; INJURY; MICROELECTRODES; NEURONS; STRAIN; PERFORMANCE; RECORDINGS;
D O I
10.1088/1741-2552/aa9dae
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Implantable neural electrode devices are important tools for neuroscience research and have an increasing range of clinical applications. However, the intricacies of the biological response after implantation, and their ultimate impact on recording performance, remain challenging to elucidate. Establishing a relationship between the neurobiology and chronic recording performance is confounded by technical challenges related to traditional electrophysiological, material, and histological limitations. This can greatly impact the interpretations of results pertaining to device performance and tissue health surrounding the implant. Approach. In this work, electrophysiological activity and immunohistological analysis are compared after controlling for motion artifacts, quiescent neuronal activity, and material failure of devices in order to better understand the relationship between histology and electrophysiological outcomes. Results. Even after carefully accounting for these factors, the presence of viable neurons and lack of glial scarring does not convey single unit recording performance. Significance. To better understand the biological factors influencing neural activity, detailed cellular and molecular tissue responses were examined. Decreases in neural activity and blood oxygenation in the tissue surrounding the implant, shift in expression levels of vesicular transporter proteins and ion channels, axon and myelin injury, and interrupted blood flow in nearby capillaries can impact neural activity around implanted neural interfaces. Combined, these tissue changes highlight the need for more comprehensive, basic science research to elucidate the relationship between biology and chronic electrophysiology performance in order to advance neural technologies.
引用
收藏
页数:23
相关论文
共 1 条
  • [1] WAND: A multi-modal dataset integrating advanced MRI, MEG, and TMS for multi-scale brain analysis
    Mcnabb, Carolyn B.
    Driver, Ian D.
    Hyde, Vanessa
    Hughes, Garin
    Chandler, Hannah L.
    Thomas, Hannah
    Allen, Christopher
    Messaritaki, Eirini
    Hodgetts, Carl J.
    Hedge, Craig
    Engel, Maria
    Standen, Sophie F.
    Morgan, Emma L.
    Stylianopoulou, Elena
    Manolova, Svetla
    Reed, Lucie
    Ploszajski, Matthew
    Drakesmith, Mark
    Germuska, Michael
    Shaw, Alexander D.
    Mueller, Lars
    Rossiter, Holly
    Davies-Jenkins, Christopher W.
    Lancaster, Tom
    Evans, C. John
    Owen, David
    Perry, Gavin
    Kusmia, Slawomir
    Lambe, Emily
    Partridge, Adam M.
    Cooper, Allison
    Hobden, Peter
    Lu, Hanzhang
    Graham, Kim S.
    Lawrence, Andrew D.
    Wise, Richard G.
    Walters, James T. R.
    Sumner, Petroc
    Singh, Krish D.
    Jones, Derek K.
    SCIENTIFIC DATA, 2025, 12 (01)