The effects of hydraulic and organic shock loads on the robustness of upflow anaerobic sludge blanket reactors treating sewage

被引:11
|
作者
Leitao, R. C.
Santaellla, S. T.
van Haandel, A. C.
Zeeman, G.
Lettinga, G.
机构
[1] Embrapa Agroind Trop, BR-60170320 Fortaleza, Ceara, Brazil
[2] Fed Univ Ceara, Dept Hydraul & Environm Engn, Fortaleza, Ceara, Brazil
[3] Wageningen Univ, Dept Environm Technol, Wageningen, Netherlands
关键词
COD removal efficiency; effluent variability; pH stability; recovery time; shock load; upflow anaerobic sludge blanket reactor;
D O I
10.2166/wst.2006.485
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this investigation, the robustness and stability of UASB reactors was evaluated on the basis of four indicators: (i) COD removal efficiency; (ii) effluent variability; (iii) pH stability; and (iv) recovery time. The experiments were carried out using six pilot-scale UASB reactors fed with domestic sewage and operated under different operational conditions. After establishment of a "steady-state", organic and hydraulic shock loads (six times the loading rate during six hours) were imposed. The results show that the UASB reactors are robust systems with regards to COD removal efficiency and pH stability when exposed to shock loads. However, this reactor cannot attenuate the imposed fluctuation in the influent COD. A secondary treatment unit is needed to retain the expelled sludge occurring as a result of a hydraulic shock load, or prior to the shock, a sufficient amount of sludge needs to be discharged from the reactor.