Optimal design of pumping stations of inland intensive fishfarms

被引:14
|
作者
Pulido-Calvo, Inmaculada [1 ]
Carlos Gutierrez-Estrada, Juan [1 ]
Asensio-Fernandez, Ricardo [1 ]
机构
[1] Univ Huelva, Dept Ciencias Agroforestales, EPS, Huelva 21819, Spain
关键词
energy savings; pump efficiency; pump scheduling; yield costs; eel;
D O I
10.1016/j.aquaeng.2006.03.004
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
An algorithm for selection of least cost or optimum pump combinations in water supply systems and to evaluate the system's energy cost of inland intensive fishfarms is presented. The model is based on solving a non-linear programming problem. Optimum design refers to the selection of pump type, capacity, and number of units that results in minimum design and operating costs for a given water demand curve. The optimization process consists of three main steps: (1) determination of fishfarm daily water requirements; (2) determination of all sets of pumping stations that satisfy the maximum requirements of flow and energy head of the fishfarm water distribution network; and (3) selection of the least-cost set among the feasible sets of pumping stations. The model was established based on data from an actual eel fishfarm in southern Spain. Application of the model shows that the optimal solution with the pump operation scheme at a constant rate (maximum requirements of flow) saved 70% of the actual total annual cost of the pumping station. The optimal solution with a variable pumping rate (pumped flow adjustment to match demand) saved 92% of the actual total annual cost with all fixed speed pump groups. Savings about 95% were obtained when one variable speed pump group was included in the optimal solution. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 50 条
  • [1] Optimal design and operation of irrigation pumping stations
    Moradi-Jalal, M
    Mariño, MA
    Afshar, A
    JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2003, 129 (03) : 149 - 154
  • [2] Optimal design and operation of pumping stations using NLP-GA
    Rasoulzadeh-Gharibdousti, Solmaz
    Bozorg-Haddad, Omid
    Marino, Miguel A.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-WATER MANAGEMENT, 2011, 164 (04) : 163 - 171
  • [3] OPTIMAL-DESIGN FOR STORM-SEWER SYSTEM WITH PUMPING STATIONS
    KUO, JT
    YEN, BC
    HWANG, GP
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 1991, 117 (01): : 11 - 27
  • [4] Optimal design of inlet conduit for technical innovation of large pumping stations
    Zhu, Honggeng
    Yuan, Shouqi
    Shuili Fadian Xuebao/Journal of Hydroelectric Engineering, 2006, 25 (02): : 51 - 55
  • [5] DESIGN OF SEWAGE PUMPING STATIONS
    KENNEDY, RR
    SEWAGE AND INDUSTRIAL WASTES, 1951, 23 (04): : 451 - 460
  • [6] DESIGN OF SEWAGE PUMPING STATIONS - DISCUSSION
    OLEWILER, GM
    SEWAGE AND INDUSTRIAL WASTES, 1951, 23 (04): : 460 - 464
  • [7] Optimal design of series of pipes in sewer systems including pumping stations for flat terrains
    Saldarriaga, Juan
    Herran, Juana
    Acevedo, Ana
    Iglesias-Rey, Pedro L.
    URBAN WATER JOURNAL, 2024, 21 (05) : 615 - 625
  • [8] Optimal Switch in Constant-Speed Pumping Stations
    Yao, Fulai
    Sun, Hexu
    ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, PT II, 2011, 7003 : 208 - 213
  • [9] Optimal design and operation of irrigation pumping stations using mathematical programming and Genetic Algorithm (GA)
    Moradi-Jalal, Mahdi
    Karney, Bryan W.
    JOURNAL OF HYDRAULIC RESEARCH, 2008, 46 (02) : 237 - 246
  • [10] CHOICE AND DESIGN OF DRIVES FOR LARGE PUMPING STATIONS
    THOMPSON, GA
    SINCLAIR, RS
    ELECTRICAL REVIEW, 1972, 191 (24): : 827 - &