Quantification of human complement C2 protein using an automated turbidimetric immunoassay

被引:6
|
作者
Tange, Clare Elizabeth [1 ]
Johnson-Brett, Bridget [1 ]
Cook, Alex [1 ]
Stordeur, Patrick [2 ]
Brohet, Fabian [2 ]
Jolles, Stephen [3 ]
Steven, Rachel [3 ]
Ponsford, Mark [3 ]
Roberts, Andrew [3 ]
El-Shanawany, Tariq [3 ]
Harding, Stephen [1 ]
Wallis, Gregg [1 ]
Parker, Antony Richard [1 ]
机构
[1] Binding Site Grp Ltd, 8 Catthorpe Rd, Birmingham B15 1QT, W Midlands, England
[2] Univ Libre Bruxelles, Immunobiol Clin, Erasme Hosp, Brussels, Belgium
[3] Univ Hosp Wales, Immunodeficiency Ctr Wales, Cardiff, S Glam, Wales
关键词
acquired angioedema (AAE); C2; complement; complement deficiency; hereditary angioedema (HAE); SPAPLUS; systemic lupus erythematosus (SLE); turbidimetry; SYSTEMIC-LUPUS-ERYTHEMATOSUS; 2ND COMPONENT; DEFICIENCY STATES; SERUM; INFECTIONS; INHIBITOR; NEWBORNS; DISEASE; INFANCY; EDEMA;
D O I
10.1515/cclm-2017-1068
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The measurement of complement components is clinically useful where a deficiency is suspected, or where excessive activation and consumption are present in disease. C2 deficiency carries an increased risk of developing systemic lupus erythematosus, recurrent infections and atherosclerosis. In this study, we have evaluated The Binding Site's Human Complement C2 SPAPLUS (R) assay. Methods: Linearity was tested using 13 sample dilutions covering the standard measuring range. Within- and between-assay variabilities were calculated using five samples with different C2 concentrations. The correlation between C2 concentrations in EDTA-plasma and serum was assessed, as was the correlation between C2 measurements by the automated assay and radial immunodiffusion. C2 concentrations were compared with CH50 activity, and quantified in individuals with homozygous or heterozygous C2 deficiency, acquired angioedema and patients with chronic inflammatory conditions. Results: The assay was linear across the measuring range (3.8-42.3 mg/L). Intra- and interassay variability were 2.3%-3.8% and 0%-3.3%, respectively. Comparison between C2 measurements in EDTA-plasma and serum provided a strong correlation (p < 0.0001, R-2=0.82, slope 0.92), as did the correlation between the automated and radial immunodiffusion methods (p< 0.0001, R-2=0.89, Conclusions: This C2 SPAPLUS (R) assay allows the automated, rapid and precice quantification of complement C2 protein and could therefore be considered as a replacement for older, more time-consuming methods.
引用
收藏
页码:1498 / 1506
页数:9
相关论文
共 50 条
  • [1] Quantification of human C1 esterase inhibitor protein using an automated turbidimetric immunoassay
    Tange, Clare E.
    Kaur, Amrit
    Verma, Nisha
    Hickey, Alaco
    Grigoriadou, Sofia
    Scott, Chris
    Kiani, Sorena
    Steven, Rachael
    Ponsford, Mark
    El-Shanawany, Tariq
    Jolles, Stephen
    Harding, Stephen
    Parker, Antony R.
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2019, 33 (01)
  • [2] Measurement of Complement C2 using the binding site SPAPLUS® turbidimetric analyzer and Complement C2 assay
    Brook, H.
    Johnson-Brett, B.
    Brohet, F.
    Stordeur, P.
    Mcentee, D.
    Murphy, F.
    Matters, D.
    Harding, S.
    CLINICA CHIMICA ACTA, 2019, 493 : S18 - S18
  • [3] A new automated turbidimetric immunoassay for the measurement of canine C-reactive protein
    Pineiro, Matilde
    Pato, Raquel
    Soler, Lourdes
    Pena, Raquel
    Garcia, Natalia
    Torrente, Carlos
    Saco, Yolanda
    Lampreave, Fermin
    Bassols, Anna
    Canalias, Francesca
    VETERINARY CLINICAL PATHOLOGY, 2018, 47 (01) : 130 - 137
  • [4] Development of an automated turbidimetric immunoassay for quantification of bovine serum immunoglobulin G
    Etzel, LR
    Strohbehn, RE
    McVicker, JK
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1997, 58 (11) : 1201 - 1205
  • [5] Calnexin is associated with and induced by overexpressed human complement protein C2
    Tsukamoto, H
    Tousson, A
    Circolo, A
    Marchase, RB
    Volanakis, JE
    ANATOMICAL RECORD, 2002, 267 (01): : 7 - 16
  • [6] TURBIDIMETRIC IMMUNOASSAY OF SERUM-C-REACTIVE PROTEIN
    OTSUJI, S
    SHIBATA, H
    UMEDA, M
    CLINICAL CHEMISTRY, 1982, 28 (10) : 2121 - 2124
  • [7] HUMAN-COMPLEMENT PROTEIN C2 - ALTERNATIVE SPLICING GENERATES TEMPLATES FOR SECRETED AND INTRACELLULAR C2 PROTEINS
    AKAMA, H
    JOHNSON, CAC
    COLTEN, HR
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1995, 270 (06) : 2674 - 2678
  • [8] Measurement of cystatin C in human urine by particle-enhanced turbidimetric immunoassay on an automated biochemistry analyzer
    Makris, Konstantinos
    Nikolaki, Efthimia
    Nanopoulos, Konstantinos
    Pirgakis, Konstantinos M.
    Maltezos, Chrisostomos K.
    CLINICAL BIOCHEMISTRY, 2013, 46 (12) : 1128 - 1130
  • [9] NOMENCLATURE FOR HUMAN-COMPLEMENT COMPONENT C2
    KAZATCHKINE, MD
    HAUPTMANN, G
    ABBAL, M
    ALPER, CA
    ARNOLD, D
    CHRISTIANSEN, F
    DAWKINS, RL
    DOXIADIS, G
    GESERICK, G
    GILES, CM
    HOBART, M
    JAHN, I
    LOKKI, ML
    MAUFF, G
    NAKAMURA, S
    ONEILL, GJ
    RITTNER, C
    SCHNEIDER, PM
    SEGURADO, OG
    SIEMENS, I
    SUZUKI, K
    TOKUNAGA, K
    URINGLAMBERT, B
    EUROPEAN JOURNAL OF IMMUNOGENETICS, 1993, 20 (04): : 299 - 300
  • [10] NOMENCLATURE FOR HUMAN-COMPLEMENT COMPONENT C2
    KAZATCHKINE, MD
    HAUPTMANN, G
    ABBAL, M
    ALPER, CA
    ARNOLD, D
    CHRISTIANSEN, F
    DAWKINS, RL
    DOXIADIS, G
    GESERICK, G
    GILES, CM
    HOBART, M
    JAHN, I
    LOKKI, ML
    MAUFF, G
    NAKAMURA, S
    ONEILL, GJ
    RITTNER, C
    SCHNEIDER, PM
    SEGURADO, OG
    SIEMENS, I
    SUZUKI, K
    TOKUNAGA, K
    URINGLAMBERT, B
    BULLETIN OF THE WORLD HEALTH ORGANIZATION, 1992, 70 (04) : 527 - 528