The histopathological diagnosis of atypical meningioma: glass slide versus whole slide imaging for grading assessment

被引:8
|
作者
Ammendola, Serena [1 ]
Bariani, Elena [1 ]
Eccher, Albino [2 ]
Capitanio, Arrigo [3 ,4 ]
Ghimenton, Claudio [2 ]
Pantanowitz, Liron [5 ,6 ]
Parwani, Anil [7 ]
Girolami, Ilaria [8 ]
Scarpa, Aldo [1 ,9 ]
Barresi, Valeria [1 ,10 ]
机构
[1] Univ Verona, Dept Diagnost & Publ Hlth, Sect Pathol, Verona, Italy
[2] Univ & Hosp Trust Verona, Dept Pathol & Diagnost, Verona, Italy
[3] Linkoping Univ, Dept Clin Pathol, Linkoping, Sweden
[4] Linkoping Univ, Dept Clin & Expt Med, Linkoping, Sweden
[5] Univ Michigan, Dept Pathol, Ann Arbor, MI 48109 USA
[6] Univ Michigan, Clin Labs, Ann Arbor, MI 48109 USA
[7] Ohio State Univ, Dept Pathol, Wexner Med Ctr, Columbus, OH 43210 USA
[8] Cent Hosp Bolzano, Div Pathol, Bolzano, Italy
[9] Univ & Hosp Trust Verona, ARC Net Res Ctr, Verona, Italy
[10] Polyclin GB Rossi, Dept Diagnost & Publ Hlth, Ple LA Scuro 10, I-37134 Verona, Italy
关键词
Atypical meningioma; Whole slide imaging; Digital; Recurrence; Reproducibility;
D O I
10.1007/s00428-020-02988-1
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Limited studies on whole slide imaging (WSI) in surgical neuropathology reported a perceived limitation in the recognition of mitoses. This study analyzed and compared the inter- and intra-observer concordance for atypical meningioma, using glass slides and WSI. Two neuropathologists and two residents assessed the histopathological features of 35 meningiomas-originally diagnosed as atypical-in a representative glass slide and corresponding WSI. For each histological parameter and final diagnosis, we calculated the inter- and intra-observer concordance in the two viewing modes and the predictive accuracy on recurrence. The concordance rates for atypical meningioma on glass slides and on WSI were 54% and 60% among four observers and 63% and 74% between two neuropathologists. The inter-observer agreement was higher using WSI than with glass slides for all parameters, with the exception of high mitotic index. For all histological features, we found median intra-observer concordance of >= 79% and similar predictive accuracy for recurrence between the two viewing modes. The higher concordance for atypical meningioma using WSI than with glass slides and the similar predictive accuracy for recurrence in the two modalities suggest that atypical meningioma may be safely diagnosed using WSI.
引用
收藏
页码:747 / 756
页数:10
相关论文
共 50 条
  • [1] The histopathological diagnosis of atypical meningioma: glass slide versus whole slide imaging for grading assessment
    Serena Ammendola
    Elena Bariani
    Albino Eccher
    Arrigo Capitanio
    Claudio Ghimenton
    Liron Pantanowitz
    Anil Parwani
    Ilaria Girolami
    Aldo Scarpa
    Valeria Barresi
    Virchows Archiv, 2021, 478 : 747 - 756
  • [2] Foreground Extraction for Histopathological Whole Slide Imaging
    Bug, Daniel
    Feuerhake, Friedrich
    Merhof, Dorit
    BILDVERARBEITUNG FUR DIE MEDIZIN 2015: ALGORITHMEN - SYSTEME - ANWENDUNGEN, 2015, : 419 - 424
  • [3] Impact of Whole Slide Imaging on Primary Diagnosis and Tumor Grading in Surgical Neuropathology
    Thomas, Diana
    Cevik, Lokman
    Becker, Aline
    Aslan, Mehmet
    Parwani, Anil
    Otero, Jose
    JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 2020, 79 (06): : 674 - 674
  • [4] Primary Histopathological Diagnosis Using Whole Slide Imaging (WSI): A Validation Study
    Gerhard, R.
    Honorio, A.
    Gentili, A.
    Brito, M. J.
    Lopes, J. M.
    Schmitt, F. C.
    LABORATORY INVESTIGATION, 2014, 94 : 399A - 399A
  • [5] Primary Histopathological Diagnosis Using Whole Slide Imaging (WSI): A Validation Study
    Gerhard, R.
    Honorio, A.
    Gentili, A.
    Brito, M. J.
    Lopes, J. M.
    Schmitt, F. C.
    MODERN PATHOLOGY, 2014, 27 : 399A - 399A
  • [6] Use of Whole-Slide Imaging System for Frozen Section Diagnosis: Comparative Study between Virtual Slide and Glass Slide Interpretation
    Khurana, K. K.
    Katzenstein, A-L A.
    Wojcik, S.
    Drogowski, L. M.
    Drotar, N.
    El-Zammar, O.
    Landas, S.
    Corona, R.
    Baxi, V.
    Montalo, M.
    MODERN PATHOLOGY, 2014, 27 : 400A - 400A
  • [7] Use of Whole-Slide Imaging System for Frozen Section Diagnosis: Comparative Study between Virtual Slide and Glass Slide Interpretation
    Khurana, K. K.
    Katzenstein, A-L A.
    Wojcik, S.
    Drogowski, L. M.
    Drotar, N.
    El-Zammar, O.
    Landas, S.
    Corona, R.
    Baxi, V.
    Montalo, M.
    LABORATORY INVESTIGATION, 2014, 94 : 400A - 400A
  • [8] Whole Slide Imaging
    Fertig, Raymond M.
    Sangueza, Omar
    Gaudi, Sudeep
    Gamret, A. Caresse
    Cervantes, Jessica
    Jukic, Drazen M.
    AMERICAN JOURNAL OF DERMATOPATHOLOGY, 2018, 40 (12) : 938 - 939
  • [9] Validation of diagnostic accuracy with whole-slide imaging compared with glass slide review in dermatopathology
    Shah, Kabeer K.
    Lehman, Julia S.
    Gibson, Lawrence E.
    Lohse, Christine M.
    Comfere, Nneka I.
    Wieland, Carilyn N.
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2016, 75 (06) : 1229 - 1237
  • [10] Whole-slide Imaging: Routine Pathologic Diagnosis
    Cornish, Toby C.
    Swapp, Ryan E.
    Kaplan, Keith J.
    ADVANCES IN ANATOMIC PATHOLOGY, 2012, 19 (03) : 152 - 159