Investigation of signal averaging on image quality in positron emission tomography

被引:0
|
作者
Balakrishnan, K [1 ]
Hichwa, RD [1 ]
Grabowski, TJ [1 ]
Madsen, MT [1 ]
Ponto, LL [1 ]
Watkins, GL [1 ]
Richmond, JC [1 ]
Bender, B [1 ]
机构
[1] Univ Iowa, Dept Phys & Astron, Iowa City, IA 52242 USA
关键词
D O I
10.1109/NSSMIC.2003.1352478
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Conventional [O-15]water PET rCBF methodology is composed of 1-10 injections of 10-50 mCi associated with multiple brain activation conditions (between 1-10). Injections occur at 10-15 min intervals. The current research compares the regional CBF signal using conventional PET studies with a method that involves summing data from 50-100 low dose injections (1-5 mCi) that have been administered in rapid but uniform succession (occurs at 1-2 min intervals) over a total study duration of 1-2 hours. This design allows for single subject studies. PET data from multiple occurrences are simulated for each specific activation condition and are summed to create a high statistics image for each activation condition. The results from the simulation are to be used to develop a computer controlled injection and data acquisition system.
引用
收藏
页码:2849 / 2852
页数:4
相关论文
共 50 条
  • [1] Averaging and Metropolis Iterations For Positron Emission Tomography
    Szirmay-Kalos, Laszlo
    Magdics, Milan
    Toth, Balazs
    Buekki, Tamas
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (03) : 589 - 600
  • [2] Influence of Slice Overlap on Positron Emission Tomography Image Quality
    McKeown, C.
    Gillen, G.
    Dempsey, M.
    Findlay, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S393 - S393
  • [3] Influence of slice overlap on positron emission tomography image quality
    McKeown, Clare
    Gillen, Gerry
    Dempsey, Mary Frances
    Findlay, Caroline
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03): : 1259 - 1277
  • [4] Characterization of time of flight and resolution modeling on image quality in positron emission tomography
    Moretti, Terrance J.
    Leon, Stephanie M.
    Schaeffer, Colin J.
    Arreola, Manuel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (10):
  • [5] Image reconstruction strategies for positron emission tomography
    Levin, CS
    MEDICAL PHYSICS, 2005, 32 (06) : 2047 - 2047
  • [6] Review on image reconstruction for positron emission tomography
    Ye, Huajun
    Liu, Huafeng
    Bao, Chao
    2002, West China University of Medical Sciences (19):
  • [7] Image reconstruction algorithms in positron emission tomography
    Comtat, Claude
    Physics for Medical Imaging Applications, 2007, 240 : 381 - 387
  • [8] Investigation of the block effect in positron emission tomography
    James, SS
    Thompson, CJ
    Tomic, N
    Kemp, B
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3370 - 3374
  • [9] Enhancement of positron emission tomography-computed tomography image quality using the principle of stochastic resonance
    Pandey, Anil Kumar
    Sharma, Sanjay Kumar
    Sharma, Punit
    Singh, Harmandeep
    Patel, Chetan
    Sarkar, Kaushik
    Kumar, Rakesh
    Bal, Chandra Sekhar
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2014, 29 (04): : 235 - 240
  • [10] Quality control of radiopharmaceuticals for positron emission tomography
    Fedorova, OS
    Korsakov, MV
    RADIOCHEMISTRY, 1998, 36 (07): : 50 - 56