Evaluation of the Effect of Pan Retinal Photocoagulation on Optic Nerve Head Parameters Using HRT3

被引:2
|
作者
Singh, Harshinder [1 ]
Garg, Satpal [1 ]
Sharma, Reetika [1 ]
Venkatesh, Pradeep [1 ]
Saxena, Rohit [1 ]
Dada, Tanuj [1 ]
机构
[1] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Facil, New Delhi 110029, India
关键词
pan retinal photocoagulation; optic nerve head parameters; confocal scanning laser ophthalmoscopy; diabetic retinopathy; global parameters; optic disc topography; TYPE-2; DIABETES-MELLITUS; FIBER LAYER; PANRETINAL PHOTOCOAGULATION; RETINOPATHY;
D O I
10.1097/IJG.0b013e3182946536
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the optic disc topography after pan retinal photocoagulation (PRP) in diabetic retinopathy patients using confocal scanning laser ophthalmoscopy (HRT3). Methods: Thirty eyes of 30 diabetic patients (non-insulin-dependent diabetes mellitus) underwent PRP for proliferative diabetic retinopathy. Subjects with glaucoma or family history of glaucoma, any coexisting neuroophthalmic disease, uveitis, retinal artery or vein occlusion, corneal opacity or lasered previously were excluded from the study. Optic nerve head (ONH) of these patients were evaluated by confocal scanning laser ophthalmoscopy (HRT3) at baseline, 3, and 6 months after completion of PRP. Results: There were 23 males and 7 females with a mean age of 51.8 years (36 to 67 y). The mean intraocular pressure was 13.1 +/- 2.57 mm Hg at baseline, 13.4 +/- 2.6 mm Hg at 3 months, and 13.3 +/- 2.2 mm Hg at 6 months (P = 0.6). The global values of ONH parameters showed no significant change from baseline at 3 months. At 6 months, there was a significant increase in vertical cup: disc ratio (P = 0.021), cup volume (P = 0.036), mean cup depth (P = 0.042), and maximum cup depth (P = 0.05) as compared with baseline values. Conclusions: PRP induces significant changes in the ONH in patients with diabetic retinopathy as measured with HRT3. This is an important consideration in the diagnosis and evaluation of progression in glaucoma patients with diabetic retinopathy who have undergone PRP.
引用
收藏
页码:467 / 470
页数:4
相关论文
共 50 条
  • [1] DISCRIMINANT UTILITY OF OPTIC-NERVE HEAD PARAMETERS IN GLAUCOMA USING THE HEIDELBERG RETINAL TOMOGRAPH (HRT)
    SHAFRANOV, G
    SCHUMER, RA
    LUSTGARTEN, JS
    PODOS, SM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1346 - 1346
  • [2] Comparision of stereometric parameters of the optic nerve head using HRT and OCT
    Mueller-Holz, M
    Schmidt, E
    Boehm, AG
    Pillunat, LE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U112 - U112
  • [3] Impact of Panretinal Photocoagulation on Optic Nerve Head Parameters
    Cankaya, Ali Bulent
    Ozdamar, Yasemin
    Ozalp, Solmaz
    Ozkan, Seyhan Sonar
    OPHTHALMOLOGICA, 2011, 225 (04) : 193 - 199
  • [4] Comparison of the depth of an optic nerve head obtained using stereo retinal images and HRT
    Nakagawa, Toshiaki
    Hayashi, Yoshinori
    Hatanaka, Yuji
    Aoyama, Akira
    Hara, Takeshi
    Kakogawa, Masakatsu
    Fujita, Hiroshi
    Yamamoto, Tetsuya
    MEDICAL IMAGING 2007: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2007, 6511
  • [5] The effects of panretinal photocoagulation on retinal nerve fiber layer at the optic nerve head
    Mohla, Aditi
    Mathur, Ranjana
    Nongpiur, Monisha Esther
    Cheung, Carol Yim-lui
    Milastuti, Nia
    Foo, Valencia
    Perera, Shamira
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [6] Change in HRT optic nerve head parameters in progressive glaucoma.
    Flanagan, JG
    Hatch, W
    WilliamsLyn, D
    Trope, GE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 3055 - 3055
  • [7] Evaluation of Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness in Axial Myopia Using SD OCT
    AttaAllah H.R.
    Omar I.A.N.
    Abdelhalim A.S.
    Ophthalmology and Therapy, 2017, 6 (2) : 335 - 341
  • [8] Reproducibility of optic nerve topographic parameters using the HRT in primates
    Bhandari, A
    Orgul, S
    Bacon, DR
    Cioffi, GA
    VanBuskirk, EM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 5016 - 5016
  • [9] VARIABILITY OF OPTIC-NERVE HEAD PARAMETERS USING THE HEIDELBERG RETINAL TOMOGRAPH
    SHAFRANOV, G
    SCHUMER, RA
    LUSTGARTEN, JS
    PODOS, SM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1507 - 1507
  • [10] OCT and HRT optic nerve head assessment: A comparison of structural and clinical parameters
    Schuman, JS
    Farra, T
    Wollstein, G
    Hertzmark, E
    Fujimoto, JG
    Mattox, CG
    Kolbe, AD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U49 - U49