This paper presents a theoretical and experimental analysis of a hybrid contactor mounted in an alternating current circuit. The hybrid contactor combines the advantages provided by the static switching and by the electromechanical switching. In the opening and closing of the contactor, the load current is taken over by the semiconducting devices mounted in parallel on each mechanical contact. Thus, the semiconducting devices take over the transient regimes and the effects of the arc on the mobile contacts are minimized. Thyristors are used for the experiments performed within the work as semiconducting devices.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] A MODEL FOR DYNAMIC ANALYSIS OF AC CONTACTOR
    KOLTERMANN, PI
    BASTOS, JPA
    ARRUDA, SR
    IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (02) : 1348 - 1350
  • [2] The analysis for contact system of intelligent AC contactor
    Xu, ZL
    Zhang, PM
    PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON RELIABILITY OF ELECTRICAL PRODUCTS AND ELECTRICAL CONTACTS, 2004, : 197 - 203
  • [3] Energy Analysis of the Closing Process of an AC Contactor
    Xu Zhihong
    Lin Shuyi
    PROCEEDINGS OF 2014 SIXTIETH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS (HOLM), 2014, : 211 - 215
  • [4] A type of intelligent hybrid AC contactor based on magnetic latching relay
    Xu, Zhihong
    Zhang, Peiming
    Weng, Guihua
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON RELIABILITY OF ELECTRICAL PRODUCTS AND ELECTRICAL CONTACTS, 2007, : 113 - 117
  • [5] AC contactor making speed measuring and theoretical analysis
    Li, WX
    Lu, JG
    Guo, H
    Li, WH
    Su, XP
    ELECTRICAL CONTACTS-2004: PROCEEDINGS OF THE 50TH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS/THE 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL CONTACTS, 2004, : 403 - 407
  • [6] New explosion-proof electric apparatus - Intelligent hybrid AC contactor
    Xu, ZH
    Zhang, PM
    Chen, L
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 4, PTS A and B, 2004, 4 : 1229 - 1234
  • [7] FINITE-ELEMENT DYNAMIC ANALYSIS FOR THE ELECTROMAGNET OF AC CONTACTOR
    WEILI, Y
    RAO, LY
    YANG, QX
    SHEN, XQ
    WANG, JG
    IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (05) : 4133 - 4135
  • [8] No-arc Control Strategy of AC/DC Contactor Based on Hybrid Commutation Technology
    Fang C.
    Xu Z.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (08): : 2468 - 2476
  • [9] Material performance analysis and structure design of the AC contactor driven by MSMA
    Zeng, Yulu
    Huang, Senlin
    Wan, Jiaxin
    Tu, Longlong
    Yu, Hongtao
    Zhu, Zhifang
    ADVANCES IN MECHANICAL ENGINEERING, 2024, 16 (06)
  • [10] Test and analysis of influence of vibration factors on the dynamic characteristics for AC contactor
    Sun S.
    Zong J.
    Wang J.
    Cui J.
    Gao H.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2020, 41 (11): : 155 - 167