Hypoxic Corneal Changes following Eight Hours of Scleral Contact Lens Wear

被引:76
|
作者
Vincent, Stephen J. [1 ]
Alonso-Caneiro, David [1 ]
Collins, Michael J. [1 ]
Beanland, Alison [1 ]
Lam, Linda [1 ]
Lim, Ching Chong [1 ]
Loke, Alyssa [1 ]
Nhi Nguyen [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Room D513,O Block,Victoria Pk Rd, Brisbane, Qld 4059, Australia
关键词
miniscleral contact lens; corneal edema; posterior corneal curvature; hypoxia; ENDOTHELIAL-CELL MORPHOLOGY; EDEMA; SHAPE;
D O I
10.1097/OPX.0000000000000803
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To examine the change in corneal thickness and posterior curvature following 8 hours of miniscleral contact lens wear. Methods Scheimpflug imaging (Pentacam HR; Oculus) was captured before, and immediately following, 8 hours of miniscleral contact lens wear for 15 young (mean age 22 3 years), healthy participants with normal corneae. Natural diurnal variations were considered by measuring baseline corneal changes obtained on a separate control day without contact lens wear. Results Over the central 6 mm of the cornea, a small but highly statistically significant amount of edema was observed following 8 hours of miniscleral lens wear, after accounting for normal diurnal fluctuations (mean +/- standard deviation percentage swelling 1.70 +/- 0.98%, p < 0.0001). Posterior corneal topography remained stable following lens wear (-0.01 +/- 0.07 mm steepening over the central 6 mm, p = 0.60). The magnitude of posterior corneal topographical changes following lens wear did not correlate with the extent of lens-related corneal edema (r = -0.16, p = 0.57). Similarly, the initial central corneal vault (maximum post-lens tear layer depth) was not associated with corneal swelling following lens removal (r = 0.27, p = 0.33). Conclusions Although a small amount of corneal swelling was induced following 8 hours of miniscleral lens wear (on average <2%), modern high Dk miniscleral contact lenses that vault the cornea do not induce clinically significant corneal edema or hypoxic-related posterior corneal curvature changes during short-term wear. Longer-term studies of compromised eyes (e.g. corneal ectasia) are still required to inform the optimum lens and fitting characteristics for safe scleral lens wear to minimize corneal hypoxia.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 50 条
  • [1] Central and Peripheral Corneal Thickness Changes during Scleral Contact Lens Wear
    Tse, Vivien
    Kim, Young Hyun
    Lin, Kristina
    Tan, Bo
    Zhou, Yixiu
    Li, Wing
    Lin, Meng C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [2] Corneal Epithelium Changes during Three Months of Scleral Contact Lens Wear
    Tse, Vivien
    Truong, Tan
    Zhou, Yixiu
    Tan, Bo
    Lin, Kristina
    Lin, Meng C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [3] Corneal Response to Scleral Contact Lens Wear in Keratoconus
    Cagliari, Cristina
    Schor, Paulo
    Formentin, Luiz
    Lipener, Cesar
    dos Santos, Myrna Serapiao
    Oliveira, Helena
    de Carvalho Raulino Junior, Jose Ney
    de Freitas, Denise
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (08): : 322 - 327
  • [4] Scleral lens wear following penetrating keratoplasty: changes in corneal curvature and optics
    Kumar, Mukesh
    Shetty, Rohit
    Lalgudi, Vaitheeswaran G.
    Vincent, Stephen J.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2020, 40 (04) : 502 - 509
  • [5] Changes in Corneal Parameters Associated with Scleral Lens Wear
    Schornack, Muriel
    Dodda, Samantha
    Nau, Cherie B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [6] Changes in eyelid position with scleral contact lens wear
    Jones, Cori
    Meyer, David
    Miles, Meagan
    Terry, Ryan
    Brintz, Benjamin
    Eddington, Devin
    Pettey, Dix
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [7] Changes in corneal thickness and ocular aberrations associated with scleral contact lens wear in normal subjects
    Yeh, Florencia
    Baker, Joshua
    Le, Ngoc
    Nguyen, Tam
    Kwon, Miae
    Tehseen, Madiha
    Putnam, Nicole M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [8] Corneal changes following short-term miniscleral contact lens wear
    Vincent, Stephen J.
    Alonso-Caneiro, David
    Collins, Michael J.
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (06): : 461 - 468
  • [9] Corneal changes following short-term rigid contact lens wear
    Tyagi, Garima
    Collins, Michael J.
    Read, Scott A.
    Davis, Brett A.
    CONTACT LENS & ANTERIOR EYE, 2012, 35 (03): : 129 - 136
  • [10] Changes in corneal Langerhans cell density during the first few hours of contact lens wear
    Alzahrani, Yahya
    Pritchard, Nicola
    Efron, Nathan
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (04): : 307 - 310