X-ray photoelectron spectroscopy, X-ray excited Auger electron spectroscopy and time-of-flight secondary ion mass spectroscopy characterization of carbon fibres activated by dc corona discharge at ambient pressure and temperature

被引:18
|
作者
Desimoni, E
Salvi, AM
Langerame, F
Watts, JF
机构
[1] UNIV BASILICATA,DIPARTIMENTO CHIM,I-85100 POTENZA,ITALY
[2] UNIV SURREY,DEPT MAT SCI & ENGN,GUILDFORD GU2 5XH,SURREY,ENGLAND
关键词
carbon fibres; corona discharge; time-of-flight secondary ion mass spectroscopy; X-ray excited auger electron spectroscopy; X-ray photoelectron spectroscopy;
D O I
10.1016/S0368-2048(97)00068-6
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
High modulus polyacrylonitrile-derived fibres were characterized by X-ray photoelectron spectroscopy, X-ray excited Auger electron spectroscopy and time-of-flight secondary ion mass spectroscopy after d.c. corona discharge treatments under a nitrogen atmosphere at ambient pressure and temperature. The results allow identification of the main functional groups produced by the treatment on the fibre surface and verification of a substantial equivalence of negative-and positive-corona discharge treatments. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:179 / 191
页数:13
相关论文
共 50 条
  • [1] Study of Asphaltene Adsorption on Kaolinite by X-ray Photoelectron Spectroscopy and Time-of-Flight Secondary Ion Mass Spectroscopy
    Wang, Shanshan
    Liu, Qi
    Tan, Xiaoli
    Xu, Chunming
    Gray, Murray R.
    ENERGY & FUELS, 2013, 27 (05) : 2465 - 2473
  • [2] X-ray photoelectron spectroscopy, photoelectron energy loss spectroscopy, X-ray excited Auger electron spectroscopy, and time-of-flight- secondary ion mass spectroscopy studies of asphaltenes from Doba-Chad heavy crude hydrovisbreaking
    Larachi, F
    Dehkissia, S
    Adnot, A
    Chornet, E
    ENERGY & FUELS, 2004, 18 (06) : 1744 - 1756
  • [3] Quantitative X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry characterization of the components in DNA
    May, CJ
    Canavan, HE
    Castner, DG
    ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1114 - 1122
  • [4] Characterization of hydrogenated graphite powder by X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry
    Xie, Wenjing
    Ng, Kai Mo
    Weng, Lu-Tao
    Chan, Chi-Ming
    RSC ADVANCES, 2016, 6 (84): : 80649 - 80654
  • [5] QUANTITATIVE SURFACE-ANALYSIS BY X-RAY PHOTOELECTRON-SPECTROSCOPY AND X-RAY EXCITED AUGER-ELECTRON SPECTROSCOPY
    EBEL, MF
    EBEL, H
    MIKROCHIMICA ACTA, 1990, 2 (1-6) : 49 - 54
  • [6] Studies of ion selective solvent polymeric membranes by X-ray photoelectron spectroscopy and time-of-flight static secondary ion mass spectroscopy
    Ye, QS
    Horvai, G
    Tóth, A
    Bertóti, I
    Botreau, M
    Duc, TM
    ANALYTICAL CHEMISTRY, 1998, 70 (20) : 4241 - 4246
  • [7] Characterization of insulin adsorption in the presence of albumin by time-of-flight secondary ion mass spectrometry and X-ray photoelectron spectroscopy
    Henry, M.
    Dupont-Gillain, C.
    Bertrand, P.
    LANGMUIR, 2008, 24 (02) : 458 - 464
  • [8] Surface analysis: X-ray photoelectron spectroscopy and auger electron spectroscopy
    Turner, NH
    Schreifels, JA
    ANALYTICAL CHEMISTRY, 2000, 72 (12) : 99R - 110R
  • [9] X-ray laser induced time-of-flight photoelectron spectroscopy
    Nelson, AJ
    Dunna, J
    van Buuren, TW
    Hunter, J
    Smith, RF
    Hemmers, O
    Lindle, DW
    SOFT X-RAY LASERS AND APPLICATIONS V, 2003, 5197 : 168 - 173
  • [10] Auger electron spectroscopy and X-ray photoelectron spectroscopy -: Principle and applications
    Barthés-Labrousse, MGV
    VIDE-SCIENCE TECHNIQUE ET APPLICATIONS, 2003, 58 (308): : 353 - +