Non-contact tape tension measurement and correlation of lateral tape motion and tape tension transients

被引:1
|
作者
Raeymaekers, Bart
Taylor, Ryan J.
Talke, Frank E.
机构
[1] Univ Calif San Diego, Ctr Magnet Recording Res 0401, La Jolla, CA 92093 USA
[2] Quantum, Costa Mesa, CA 92626 USA
关键词
D O I
10.1007/s00542-006-0205-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Non-contact tension measurement of magnetic tape is performed. Light from a focussed light source is directed at a tape surface and the light reflected from the tape is captured by a photo cell. As the tape tension varies, the divergence of the reflected light bundle changes, i.e., the amount of light seen by the photo cell is a measure for the tension in the tape. Using this non-contact tension measurement approach and a high frequency lateral tape motion sensor, we have investigated the correlation between high frequency tension changes and high frequency lateral tape motion. Strong correlation is observed between the absolute values of tension and lateral tape motion.
引用
收藏
页码:814 / 821
页数:8
相关论文
共 50 条
  • [1] Non-contact tape tension measurement and correlation of lateral tape motion and tape tension transients
    Bart Raeymaekers
    Ryan J. Taylor
    Frank E. Talke
    Microsystem Technologies, 2006, 12 : 814 - 821
  • [2] Effects of operating speed and tension and sources of lateral tape motion in a linear tape drive
    Hansen, WS
    Bhushan, B
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (02) : 826 - 848
  • [3] MEASUREMENT AND RECORDING OF TENSION OF FILM AND TAPE
    SAXL, EJ
    PHOTOGRAPHIC SCIENCE AND ENGINEERING, 1965, 9 (01): : 36 - &
  • [4] High frequency lateral tape motion and the dynamics of tape edge contact
    Taylor, RJ
    Talke, FE
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2005, 11 (8-10): : 1166 - 1170
  • [5] High frequency lateral tape motion and the dynamics of tape edge contact
    Ryan J. Taylor
    Frank E. Talke
    Microsystem Technologies, 2005, 11 : 1166 - 1170
  • [6] TENSION GRADIENT MEASUREMENT OF MAGNETIC-TAPE
    HU, PY
    HOLLMAN, W
    ARGUMEDO, AJ
    IEEE TRANSACTIONS ON MAGNETICS, 1984, 20 (05) : 921 - 923
  • [7] Correlation of tape location and tension with surgical outcome after transobturator suburethral tape procedures
    Yang, J. -M.
    Yang, S. -H.
    Huang, W. -C.
    Tzeng, C. -R.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (04) : 458 - 465
  • [8] Pole tip recession in linear tape heads: measurement technique and influence of head materials, tape speed and tape tension
    Scott, WW
    Bhushan, B
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 1999, 213 (J2) : 139 - 150
  • [9] TENSION IN COIL AND TAPE WINDING
    SAXL, EJ
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1958, 46 (03): : 628 - 628
  • [10] CHECK YOUR TAPE TENSION
    MCCLURG, DR
    DB-SOUND ENGINEERING MAGAZINE, 1977, 11 (01): : 28 - 30