Efficacy of an Extracorporeal Endotoxin Adsorber System during Hyperdynamic Porcine Endotoxemia

被引:7
|
作者
Bracht, H. [1 ]
Hauser, B. [1 ]
Ivanyi, Z. [1 ]
Asfar, P. [1 ]
Ehrmann, U. [1 ]
Brueckner, U. B. [2 ]
GeorgieffA, M. [1 ]
Radermacher, P. [1 ]
Buttenschoen, K. [3 ]
机构
[1] Univ Ulm Klinikum, Sekt Anesthesiol Pathophysiol & Verfahrensentwick, DE-89073 Ulm, Germany
[2] Univ Ulm Klinikum, Sekt Chirurg Forsch, DE-89073 Ulm, Germany
[3] Univ Ulm Klinikum, Abt Allgemein Visceral & Transplantat Chirurg, DE-89073 Ulm, Germany
关键词
Endotoxin adsorber; Immobilized human serum albumin; Animal trial; Pig; Endotoxic shock; B-IMMOBILIZED FIBER; GRAM-NEGATIVE SEPSIS; SEPTIC SHOCK; CONTROLLED-TRIAL; SHORT-TERM; HEMOPERFUSION; COLUMN; HEMOFILTRATION; BACTEREMIA; ADSORPTION;
D O I
10.1159/000218330
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Endotoxemia is a crucial factor in the pathogenesis of sepsis. Elimination of endotoxin is aimed at the reduction of sepsis-related morbidity and lethality. The objective of this study was to examine the impact of an endotoxin adsorber on hemodynamics, O(2) exchange and metabolism during resuscitated porcine endotoxemia. Methods: Twenty pigs were randomized into 2 intervention groups (n = 7 each) and 1 control group (n = 6). Endotoxemia was induced by continuous intravenous application of lipopolysaccharide for 8 h. Adsorber therapy was started at the same time as the induction of endotoxemia or 2 h later. An extracorporeal hemoperfusion device using immobilized human serum albumin for endotoxin adsorption was used. Results: Hemodynamic, metabolic and acid-base parameters, as well as the kinetics of interleukin (IL)-6, IL-8, IL-10 and tumor necrosis factor-alpha, were characteristic for endotoxic shock. Endotoxin plasma levels were low (arterial, hepatic and portal vein). None of the parameters were significantly influenced by the adsorber system. Conclusion: Despite typical clinical signs of endotoxemia, the adsorber system had no significant effect on hemodynamic, metabolic and acid-base parameters during endotoxic shock. The reasons for the absence of an effect are elusive; however, failure of the method per se or exceeded capacity of the adsorber cannot be excluded. Copyright (C) 2009 S. Karger AG, Basel
引用
收藏
页码:53 / 60
页数:8
相关论文
共 50 条
  • [1] EFFICACY OF AN EXTRACORPOREAL ENDOTOXIN ADSORBER SYSTEM DURING HYPERDYNAMIC PORCINE ENDOTOXEMIA
    Hauser, Balazs
    Radermacher, P.
    Buttenschoen, K.
    Bracht, H.
    SHOCK, 2009, 32 : 13 - 13
  • [2] Ileal microcirculation and mucosal acidosis during hyperdynamic porcine endotoxemia
    I Tugtekin
    M Matejovic
    A Stehr
    M Theisen
    F Ploner
    K Träger
    M Georgieff
    P Radermacher
    Critical Care, 4 (Suppl 1):
  • [3] Effective pulmonary capillary pressure during hyperdynamic porcine endotoxemia
    T Handschuh
    D Vasilev
    M Georgieff
    P Radermacher
    B Šantak
    Critical Care, 4 (Suppl 1):
  • [4] ATP-MgCl2 during hyperdynamic porcine endotoxemia
    Taylor, FB
    CRITICAL CARE MEDICINE, 2002, 30 (08) : 1923 - 1923
  • [5] Effects of mercaptoethylguanidine during long-term hyperdynamic porcine endotoxemia
    F Ploner
    I Tugtekin
    M Matejovic
    M Theisen
    A Stehr
    C Szabo
    UB Brückner
    P Radermacher
    Critical Care, 4 (Suppl 1):
  • [6] LEFT-VENTRICULAR PERFORMANCE DURING CONTINUOUS ENDOTOXIN-INDUCED HYPERDYNAMIC ENDOTOXEMIA IN SHEEP
    NOSHIMA, S
    NODA, H
    HERNDON, DN
    TRABER, LD
    TRABER, DL
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (04) : 1528 - 1533
  • [7] REDISTRIBUTION OF INTRAORGAN BLOOD-FLOW IN ACUTE, HYPERDYNAMIC PORCINE ENDOTOXEMIA
    KREIMEIER, U
    HAMMERSEN, F
    RUIZMORALES, M
    YANG, Z
    MESSMER, K
    EUROPEAN SURGICAL RESEARCH, 1991, 23 (02) : 85 - 99
  • [8] Effect of iNOS inhibition on exhaled NO and serum nitrate in hyperdynamic porcine endotoxemia
    MM Theisen
    D Vasilev
    J Altherr
    M Matejovic
    I Tugtekin
    M Georgieff
    P Radermacher
    Critical Care, 4 (Suppl 1):
  • [9] TIN-mesoporphyrin for inhibition of heme oxygenase during long-term hyperdynamic porcine endotoxemia
    Nalos, M
    Vassilev, D
    Pittner, A
    Asfar, P
    Brückner, UB
    Schneider, EM
    Georgieff, M
    Radermacher, P
    Froeba, G
    SHOCK, 2003, 19 (06): : 526 - 532
  • [10] Treatment with the extracorporeal endotoxin adsorber matisse in gram-negative sepsis
    Reinhart, K
    Meier-Hellmann, A
    Beale, R
    Böhme, M
    Hoffmann, J
    INTENSIVE CARE MEDICINE, 2003, 29 : S26 - S26