Impact of gender on rest Tc-99m sestamibi-gated left ventricular election fraction

被引:7
|
作者
Kane, GC [1 ]
Hauser, MF [1 ]
Behrenbeck, TR [1 ]
Miller, TD [1 ]
Gibbons, RJ [1 ]
Christian, TF [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Dept Internal Med, Rochester, MN 55905 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2002年 / 89卷 / 10期
关键词
D O I
10.1016/S0002-9149(02)02317-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left ventricular ejection fraction was measured during the same technetium-99m sestamibi study in 239 patients by first-pass and gated single-photon emission computed tomographic methods. There was a significant difference between left ventricular ejection fraction values recorded by the 2 methods between men and women that was independent of age, body size, heart rate, infarct size, or ventricular volumes.
引用
收藏
页码:1238 / +
页数:5
相关论文
共 50 条
  • [1] MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION FROM GATED TC-99M SESTAMIBI MYOCARDIAL IMAGES
    BOONYAPRAPA, S
    EKMAHACHAI, M
    THANACHAIKUN, N
    JAIPRASERT, W
    SUKTHOMYA, V
    PORAMATIKUL, N
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (06): : 528 - 531
  • [2] A geometric method of measuring the left ventricular ejection fraction on gated Tc-99m sestamibi myocardial imaging
    Miron, SD
    Finkelhor, R
    Penuel, PH
    Bahler, R
    Bellon, EM
    CLINICAL NUCLEAR MEDICINE, 1996, 21 (06) : 439 - 444
  • [3] EJECTION FRACTION WITH PLANAR GATED TC-99M SESTAMIBI MYOCARDIAL IMAGES
    SZULC, M
    HERROLD, EM
    ZANZONICO, P
    BORER, JS
    CLINICAL RESEARCH, 1993, 41 (03): : A610 - A610
  • [4] EJECTION FRACTION WITH PLANAR GATED TC-99M SESTAMIBI MYOCARDIAL IMAGES
    SZULC, M
    HERROLD, EM
    ZANZONICO, P
    BORER, JS
    CIRCULATION, 1993, 88 (04) : 582 - 582
  • [5] Automated calculation of left ventricular ejection fraction from gated Tc-99m sestamibi myocardial images - Comparison to quantitative echocardiography
    Zanger, DR
    Bhatnagar, A
    Hausner, E
    Botello, MF
    Nuquist, CE
    Martinez, AI
    Welssman, NJ
    Cerqueira, MD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 98546 - 98546
  • [6] AUTOMATIC-MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION BY GATED SPECT TC-99M SESTAMIBI - A COMPARISON WITH RADIONUCLIDE VENTRICULOGRAPHY
    MORIEL, M
    GERMANO, G
    KIAT, H
    FRIEDMAN, J
    HYUN, M
    TINKER, T
    BERMAN, DS
    CIRCULATION, 1993, 88 (04) : 582 - 582
  • [7] Usefulness of dobutamine Tc-99m sestamibi-gated single-photon emission computed tomography for prediction of left ventricular ejection fraction outcome after coronary revascularization for ischemic cardiomyopathy
    Leoncini, M
    Sciagrà, R
    Maioli, M
    Bellandi, F
    Marcucci, G
    Sestini, S
    Chiocchini, S
    Dabizzi, RP
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (07): : 817 - 821
  • [8] Gated SPECT Tc-99m N-NOET myocardial perfusion studies provide similar information regarding left ventricular ejection fraction and volumes as Tc-99m sestamibi.
    Magram, MY
    Line, BR
    Zinnes, A
    Lodge, MA
    Magram, DN
    Shankovich, A
    Bacetti, N
    Dilsizian, V
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 86P - 87P
  • [9] Quantitative left ventricular ejection fraction derived from gated Tl-201 perfusion SPECT: Comparison with gated Tc-99m sestamibi SPECT
    Erel, J
    Germano, G
    Kiat, H
    Friedman, JD
    Kavanagh, PB
    Berman, DS
    CIRCULATION, 1996, 94 (08) : 1766 - 1766
  • [10] Tc-99m sestamibi gated SPECT in patients with left bundle branch block
    Inanir, S
    Caymaz, O
    Okay, T
    Dede, F
    Oktay, A
    Deger, M
    Turoglu, HT
    CLINICAL NUCLEAR MEDICINE, 2001, 26 (10) : 840 - 846