Performance Analysis of Flat-Plate and V-groove Solar Air Heater Through CFD Simulation

被引:13
|
作者
Desisa, Debela Geneti [1 ]
Shekata, Gadisa Desa [2 ]
机构
[1] Jimma Univ, Fac Mech Engn, Jimma Inst Technol, Jimma, Ethiopia
[2] Wolkite Univ, Coll Engn & Technol, Dept Mech Engn, Wolkite, Ethiopia
关键词
CFD simulation; V-grooved surface; smooth surface; rough surface; double pass; TRANSFER ENHANCEMENT; COLLECTORS; DESIGN; ENERGY; SYSTEM;
D O I
10.14710/ijred.2020.30091
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The simplicity of solar flat plate air collector and free availability of solar energy sources attract attention to the optimization of the collector. This study aims to assess the effect of double pass air flow on the performance of flat plate air collectors. The analysis of the performance characteristics of the indirect solar dryer was carried out by CFD simulation with three different smooth, rough and V-grooved surfaces, keeping the lower and lateral collector well insulated and the drying chamber acting as a vertical chimney. The average thermal efficiency of the V-grooved surface, smooth surface, and rough surface is 90%, 78%, and 62% respectively. The total area of the collector is 1.20 x 2.0 = 2.40 m(2) with the dimension of drying cabinet width, depth, and height 1200 x 650 x 1000 mm respectively. The pressure drop observed at the entrance to the drying chamber is high in the case of a smooth surface, medium in a rough surface and low in a V-grooved plate which will allow sufficient gas pressure to pass through completely. The air mass flow rate is the most important and effective factor during drying. The humidity of the air, as well as air velocity, is also an important factor in improving the drying rate. (c) 2020. CBIORE-IJRED. All rights reserved
引用
收藏
页码:369 / 381
页数:13
相关论文
共 50 条
  • [1] PARAMETRIC ANALYSIS OF A SUSPENDED FLAT-PLATE SOLAR AIR HEATER
    YADAV, YP
    KUMAR, A
    SHARAN, LB
    SRIVASTAVA, VP
    ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (05) : 325 - 335
  • [2] Thermal Performance Evaluation for Two Designs of Flat-Plate Solar Air Heater: An Experimental and CFD Investigations
    El-Sebaey, Mahmoud S.
    Ellman, Asko
    El-Din, Sh. Shams
    Essa, Fadl A.
    PROCESSES, 2023, 11 (04)
  • [3] PERFORMANCE OF SUSPENDED FLAT-PLATE AIR HEATER
    RANJAN, V
    DHIMAN, NK
    TIWARI, GN
    ENERGY CONVERSION AND MANAGEMENT, 1983, 23 (04) : 211 - 215
  • [4] Numerical simulation of solar air heater with V-groove absorber used in HD desalination
    Cheng, Guangping
    Zhang, Lixi
    DESALINATION AND WATER TREATMENT, 2011, 28 (1-3) : 239 - 246
  • [5] PERFORMANCE OF A 2-CHANNEL SUSPENDED FLAT-PLATE SOLAR AIR HEATER
    DHIMAN, NK
    TIWARI, GN
    ENERGY CONVERSION AND MANAGEMENT, 1984, 24 (04) : 269 - 275
  • [6] Numerical simulation on V shaped solar flat-plate air collector
    Chen, Mingdong
    Liu, Xuebing
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 2175 - 2178
  • [7] TRANSIENT AND ANALYTICAL SOLUTION OF SUSPENDED FLAT-PLATE SOLAR AIR HEATER
    YADAV, YP
    TIWARI, GN
    ENERGY CONVERSION AND MANAGEMENT, 1986, 26 (3-4) : 265 - 269
  • [8] Energy, exergy, economic and environmental (4E) analyses of flat-plate and V-groove solar air collectors based on aluminium and copper
    Abuska, Mesut
    Sevik, Seyfi
    SOLAR ENERGY, 2017, 158 : 259 - 277
  • [9] Outdoor experimental investigation of a solar flat-plate air heater with honeycomb structure
    Ye, H
    Ge, XS
    Wang, GJ
    Xu, QT
    Xi, YM
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 1218 - 1222
  • [10] ANALYSIS OF A FLAT-PLATE SOLAR COLLECTOR STORAGE WATER HEATER WITH EVAPORATION
    TIWARI, GN
    HUSAIN, MS
    GARG, HP
    ENERGY, 1984, 9 (04) : 351 - 360