Monte Carlo study of global interference cancellation by multidistance measurement of near-infrared spectroscopy

被引:36
|
作者
Umeyama, Shinji [1 ]
Yamada, Toru [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Neurosci Res Inst, Tsukuba, Ibaraki 3058568, Japan
关键词
near-infrared spectroscopy; multidistance measurement; interference cancellation; Monte Carlo simulation; ADULT HEAD MODEL; LIGHT-PROPAGATION; TISSUE;
D O I
10.1117/1.3275466
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of near-infrared spectroscopy is sometimes degraded by the systemic physiological interference in the extracerebral layer. There is some systemic interference, which is highly correlated with the functional response evoked by a task execution. This kind of interference is difficult to remove by using ordinary techniques. A multidistance measurement method is one of the possible solutions for this problem. The multidistance measurement method requires estimation parameters derived from partial pathlength values of tissue layers to calculate an absorption coefficient change from a temporal absorbance change. Because partial path lengths are difficult to obtain, experimentally, we estimated them by a Monte Carlo simulation based on a five-layered slab model of a human adult head. Model parameters such as thickness and the transport scattering coefficient of each layer depend on a subject and a measurement position; thus, we assumed that these parameters obey normal distributions around standard parameter values. We determined the estimation parameters that provide a good separation performance in average for the model parameter distribution. The obtained weighting is robust to model parameter deviation and provides smaller errors on average compared to the parameters, which are determined without considering parameter distribution. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3275466]
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Reduction of global interference in functional multidistance near-infrared spectroscopy using empirical mode decomposition and recursive least squares: a Monte Carlo study
    Zhang, Y.
    Sun, J.
    Rolfe, P.
    JOURNAL OF THE EUROPEAN OPTICAL SOCIETY-RAPID PUBLICATIONS, 2011, 6 : 28
  • [2] Monte Carlo study for physiological interference reduction in near-infrared spectroscopy based on empirical mode decomposition
    Zhang, Yan
    Sun, JinWei
    Rolfe, Peter
    JOURNAL OF MODERN OPTICS, 2010, 57 (21) : 2159 - 2169
  • [3] Multidistance probe arrangement to eliminate artifacts in functional near-infrared spectroscopy
    Yamada, Toru
    Umeyama, Shinji
    Matsuda, Keiji
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (06)
  • [4] Near-Infrared Brain Volumetric Imaging Method: A Monte Carlo Study
    Chuang, Ching-Cheng
    Wang, Pei-Ning
    Chen, Wei-Ta
    Lan, Tsuo-Hung
    Chen, Chung-Ming
    Hsieh, Yao-Sheng
    Wang, Chun-Yang
    Sun, Chia-Wei
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2012, 18 (03) : 1122 - 1129
  • [5] The development of Monte Carlo technique for determination of skin oxygenation by near-infrared spectroscopy.
    Meglinski, IV
    Matcher, SJ
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS III, PROCEEDINGS OF, 1999, 3598 : 279 - 287
  • [6] Wearable and modular functional near-infrared spectroscopy instrument with multidistance measurements at four wavelengths
    Wyser, Dominik
    Lambercy, Olivier
    Scholkmann, Felix
    Wolf, Martin
    Gassert, Roger
    NEUROPHOTONICS, 2017, 4 (04)
  • [7] The near-infrared reflectance spectrum of skin: A Monte Carlo simulation
    Tsai, C.-L.
    Chou, Y.-S.
    Tsai, J.-Y.
    Biomedical Engineering - Applications, Basis and Communications, 1998, 10 (03): : 165 - 170
  • [8] Near-infrared spectroscopy A measurement tool for 'vegetables'?
    Arguelles-Delgado, Placido M.
    Dworschak, Martin
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2019, 36 (06) : 469 - 469
  • [9] NEAR-INFRARED OXIMETRY AND NEAR-INFRARED SPECTROSCOPY
    OWENREECE, H
    ELWELL, CE
    FALLON, P
    GOLDSTONE, J
    SMITH, M
    ANAESTHESIA, 1994, 49 (12) : 1102 - 1103
  • [10] Effect of head model on Monte Carlo modeling of spatial sensitivity distribution for functional near-infrared spectroscopy
    Li, Ting
    Li, Yan
    Sun, Yunlong
    Duan, Meixue
    Peng, Liyuan
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2015, 8 (05)