Comparative 5-Year Results of Short Hip Total Hip Arthroplasty with Ti- or CoCr-Neck Adapters

被引:6
|
作者
Wittenberg, Ralf H. [1 ]
Steffen, Reinhard [2 ]
机构
[1] St Elizabeth Hosp, Vest Othopad Klin, D-45699 Herten Westfalen, Germany
[2] Marienkrankenhaus Kaiserswert, Abt Orthopadie, Dusseldorf Kaiserswert, Germany
关键词
SHORT-STEM; FEMORAL COMPONENTS; FOLLOW-UP; REPLACEMENT; PROSTHESIS; FIXATION; FAILURE;
D O I
10.3928/01477447-20150215-54
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This prospective study investigated revision after modular short stem implantation. Results are presented for 2 different types of neck adapters (titanium and cobalt-chromium [CoCr]). Eighty-five patients with titanium adapters and 87 patients with CoCr adapters underwent follow-up examination after an average of 5.7 and 5.2 years, respectively. Mean patient age was 57 years in both groups. Indications were primary osteoarthritis (80%), cup dysplasia (14%), and other (6%). Mean Harris Hip Scores were 98 and 99 points (titanium and CoCr groups, respectively). Ninety percent and 96% of patients were very satisfied or satisfied (titanium and CoCr groups, respectively); 3% of patients in both groups were dissatisfied. Pain decreased from visual analog scale score 7 and 6 preoperatively to 0.37 and 0.15 postoperatively for the titanium and CoCr groups, respectively. No joint dislocation occurred. Six patients needed revision within the first year (2 for infection, 1 for via falsa position, and 2 for aseptic loosening in the titanium group, and 1 for aseptic loosening in the CoCr group). Nine revisions occurred due to neck adapter failure (titanium group). Primary standard stems were used in all revisions. Excluding material-related adapter failures in the titanium group, the 5-year survival rate was 94.8% (95% confidence interval [CI], 88.9-97.6 for titanium) and 99% (95% CI, 93.7-99.8 for CoCr). No radiographic signs of loosening were seen at last follow-up. Fine sclerotic lines were detected in Gruen zones 1 (17.2%) and 2 (14%), hypertrophies in zone 3 (4.3%), and periprosthetic cancellous bone compressions in zone 6 (75.8%). No adapter fractures occurred for CoCr components. The treatment and anchoring system of the short stem studied yielded good results and allowed revision using standard stems in all patients.
引用
收藏
页码:S33 / S39
页数:7
相关论文
共 50 条
  • [1] The cementless ACA total hip arthroplasty system - 5-year results.
    Matzen, KA
    Stockmaier, K
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (05): : 420 - 427
  • [2] Minimum 5-Year Results of Modular Metal-On-Metal Total Hip Arthroplasty
    Kindsfater, Kirk A.
    Terefenko, Christi J. Sychterz
    Gruen, Thomas A.
    Sherman, Cynthia M.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (04): : 545 - 550
  • [3] Optimys short stem in primary total hip arthroplasty: a 5-year analysis of 268 cases
    Teufel, Victoria
    Hess, Rolf
    Spycher, Jonathan
    Thomann, Sergio
    Brand, Christian
    Bolliger, Lilianna
    Beck, Martin
    SWISS MEDICAL WEEKLY, 2023, 153 : 78S - 78S
  • [4] 5-YEAR EXPERIENCE OF AN OPERATIVE PROGRAM FOR TOTAL HIP-ARTHROPLASTY
    HERBERTS, P
    ROMANUS, B
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (04): : 475 - 475
  • [5] Cementless femoral fixation in the rheumatoid patient undergoing total hip arthroplasty - Minimum 5-year results
    Keisu, KS
    Orozco, F
    McCallum, JD
    Bissett, G
    Hozack, WJ
    Sharkey, PF
    Rothman, RH
    JOURNAL OF ARTHROPLASTY, 2001, 16 (04): : 415 - 421
  • [6] HYDROXYAPATITE IN TOTAL HIP-ARTHROPLASTY - 5-YEAR CLINICAL-EXPERIENCE
    CAPELLO, WN
    ORTHOPEDICS, 1994, 17 (09) : 781 - &
  • [7] Cost analysis of revision total hip arthroplasty -: A 5-year followup study
    Barrack, RL
    Sawhney, J
    Hsu, J
    Cofield, RH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (369) : 175 - 178
  • [8] CEMENTLESS GUSTILO-KYLE AND BIAS TOTAL HIP-ARTHROPLASTY - 2-YEAR TO 5-YEAR RESULTS
    KIENAPFEL, H
    MARTELL, J
    ROSENBERG, A
    GALANTE, J
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1991, 110 (04) : 179 - 186
  • [9] A titanium-encased alumina ceramic bearing for total hip arthroplasty - 3-to 5-year results
    D'Antonio, JA
    Capello, WN
    Manley, MT
    Naughton, M
    Sutton, K
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 151 - 158
  • [10] Uncemented total hip arthroplasty in Paget's disease of the hip - A report of 5 cases with 5-year follow-up
    Hozack, WJ
    Rushton, SA
    Carey, C
    Sakalkale, D
    Rothman, RH
    JOURNAL OF ARTHROPLASTY, 1999, 14 (07): : 872 - 876