Zernike Ultrasonic Tomography for Fluid Velocity Imaging Based on Pipeline Intrusive Time-of-Flight Measurements

被引:9
|
作者
Besic, Nikola [1 ,2 ]
Vasile, Gabriel [1 ]
Anghel, Andrei [1 ,4 ]
Petrut, Teodor-Ion [1 ]
Ioana, Cornel [1 ]
Stankovic, Srdjan [3 ]
Girard, Alexandre [5 ]
d'Urso, Guy [5 ]
机构
[1] CNRS Grenoble INP, GIPSA lab, Grenoble, France
[2] Univ Montenegro, Podgorica, Montenegro
[3] Univ Montenegro, Fac Elect Engn, Podgorica, Montenegro
[4] Univ Politehn, Fac Elect Telecommun & Informat Technol, Bucharest, Romania
[5] EDF, R&D, Chatou, France
关键词
FLOW METER; WAVE-PROPAGATION;
D O I
10.1109/TUFFC.2014.006515
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, we propose a novel ultrasonic tomography method for pipeline flow field imaging, based on the Zernike polynomial series. Having intrusive multipath time-of-flight ultrasonic measurements (difference in flight time and speed of ultrasound) at the input, we provide at the output tomograms of the fluid velocity components (axial, radial, and orthoradial velocity). Principally, by representing these velocities as Zernike polynomial series, we reduce the tomography problem to an ill-posed problem of finding the coefficients of the series, relying on the acquired ultrasonic measurements. Thereupon, this problem is treated by applying and comparing Tikhonov regularization and quadratically constrained l 1 minimization. To enhance the comparative analysis, we additionally introduce sparsity, by employing SVD-based filtering in selecting Zernike polynomials which are to be included in the series. The first approach-Tikhonov regularization without filtering, is used because it is the most suitable method. The performances are quantitatively tested by considering a residual norm and by estimating the flow using the axial velocity tomogram. Finally, the obtained results show the relative residual norm and the error in flow estimation, respectively, similar to 0.3% and similar to 1.6% for the less turbulent flow and similar to 0.5% and similar to 1.8% for the turbulent flow. Additionally, a qualitative validation is performed by proximate matching of the derived tomograms with a flow physical model.
引用
收藏
页码:1846 / 1855
页数:10
相关论文
共 50 条
  • [1] A modified time-of-flight tomography concept for ultrasonic breast imaging
    Krueger, M
    Pesavento, A
    Ermert, H
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1381 - 1385
  • [2] Time-of-Flight Based Calibration of an Ultrasonic Computed Tomography System
    Filipik, Adam
    Jan, Jiri
    Peterlik, Igor
    RADIOENGINEERING, 2012, 21 (01) : 533 - 544
  • [3] INEXPENSIVE TIME-OF-FLIGHT VELOCITY-MEASUREMENTS
    EVERETT, GE
    WILD, RL
    AMERICAN JOURNAL OF PHYSICS, 1979, 47 (05) : 426 - 428
  • [4] Modified Time-of-Flight Based Calibration Approach for Ultrasonic Computed Tomography
    Filipik, Adam
    Jan, Jiri
    Peterlik, Igor
    Hemzal, Dusan
    Ruiter, Nicole
    Jirik, Radovan
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2181 - +
  • [5] Frequency Based Radial Velocity Estimation in Time-of-Flight Range Imaging
    Lickfold, Carl A.
    Streeter, Lee
    Cree, Michael J.
    Scott, Jonathan B.
    2019 INTERNATIONAL CONFERENCE ON IMAGE AND VISION COMPUTING NEW ZEALAND (IVCNZ), 2019,
  • [6] RECONSTRUCTION OF INTERNAL TEMPERATURE DISTRIBUTION FROM ULTRASONIC TIME-OF-FLIGHT TOMOGRAPHY AND DIMENSIONAL RESONANCE MEASUREMENTS
    NORTON, SJ
    TESTARDI, LR
    WADLEY, HNG
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (01): : 79 - 79
  • [7] RECONSTRUCTING INTERNAL TEMPERATURE DISTRIBUTIONS FROM ULTRASONIC TIME-OF-FLIGHT TOMOGRAPHY AND DIMENSIONAL RESONANCE MEASUREMENTS
    NORTON, SJ
    TESTARDI, LR
    WADLEY, HNG
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1984, 89 (01): : 65 - 74
  • [9] Study of ultrasonic thermometry based on ultrasonic time-of-flight measurement
    Jia, Ruixi
    Xiong, Qingyu
    Wang, Lijie
    Wang, Kai
    Shen, Xuehua
    Liang, Shan
    Shi, Xin
    AIP ADVANCES, 2016, 6 (03):
  • [10] Calibrating an ultrasonic computed tomography system using a time-of-flight based positioning algorithm
    Filipik, Adam
    Peterlik, Igor
    Hemzal, Dusan
    Jan, Jiri
    Jirik, Radovan
    Zapf, Michael
    Ruiter, Nicole
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2146 - +