Monitoring of Nitrification in Chloraminated Drinking Water Distribution Systems With Microbiome Bioindicators Using Supervised Machine Learning

被引:9
|
作者
Gomez-Alvarez, Vicente [1 ]
Revetta, Randy P. [1 ]
机构
[1] US EPA, Off Res & Dev, Cincinnati, OH 45268 USA
关键词
nitrification; bioindicators; receiver-operating characteristic; microbiome; machine learning; COMMUNITIES; CLASSIFICATION; RISK;
D O I
10.3389/fmicb.2020.571009
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Many drinking water utilities in the United States using chloramine as disinfectant treatment in their drinking water distribution systems (DWDS) have experienced nitrification episodes, which detrimentally impact the water quality. Identification of potential predictors of nitrification in DWDS may be used to optimize current nitrification monitoring plans and ultimately helps to safeguard drinking water and public health. In this study, we explored the water microbiome from a chloraminated DWDS simulator operated through successive operational schemes of stable and nitrification events and utilized the 16S rRNA gene dataset to generate high-resolution taxonomic profiles for bioindicator discovery. Analysis of the microbiome revealed both an enrichment and depletion of various bacterial populations associated with nitrification. A supervised machine learning approach (naive Bayes classifier) trained with bioindicator profiles (membership and structure) were used to classify water samples. Performance of each model was examined using the area under the curve (AUC) from the receiver-operating characteristic (ROC) and precision-recall (PR) curves. The ROC- and PR-AUC gradually increased to 0.778 and 0.775 when genus-level membership (i.e., presence and absence) was used in the model and increased significantly using structure (i.e., distribution) dataset (AUCs = 1.000,p< 0.01). Community structure significantly improved the predictive ability of the model beyond that of membership only regardless of the type of data (sequence- or taxonomy-based model) we used to represent the microbiome. In comparison, an ATP-based model (bulk biomass) generated a lower AUCs of 0.477 and 0.553 (ROC and PR, respectively), which is equivalent to a random classification. A combination of eight bioindicators was able to correctly classify 85% of instances (nitrification or stable events) with an AUC of 0.825 (sensitivity: 0.729, specificity: 0.894) on a full-scale DWDS test set. Abiotic-based model using total Chlorine/NH2Cl and NH(3)generated AUCs of 0.740 and 0.861 (ROC and PR, respectively), corresponding to a sensitivity of 0.250 and a specificity of 0.957. The AUCs increased to > 0.946 with the addition of NO(2)(-)concentration, which is indicative of nitrification in the DWDS. This research provides evidence of the feasibility of using bioindicators to predict operational failures in the system (e.g., nitrification).
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Nitrification modeling in pilot-scale chloraminated drinking water distribution systems
    Yang, Jian
    Harrington, Gregory W.
    Noguera, Daniel R.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2008, 134 (09) : 731 - 742
  • [2] Investigation of Chloramines, Disinfection Byproducts, and Nitrification in Chloraminated Drinking Water Distribution Systems
    Abulikemu, Gulizhaer
    Mistry, Jatin H.
    Wahman, David G.
    Alexander, Matthew T.
    Kennicutt, Alison R.
    Bollman, Jacob D.
    Pressman, Jonathan G.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2023, 149 (01)
  • [3] Developing a chloramine decay index to understand nitrification:A case study of two chloraminated drinking water distribution systems
    Sina Moradi
    Sanly Liu
    Christopher W.K.Chow
    John van Leeuwen
    David Cook
    Mary Drikas
    Rose Amal
    Journal of Environmental Sciences, 2017, 57 (07) : 170 - 179
  • [4] Developing a chloramine decay index to understand nitrification: A case study of two chloraminated drinking water distribution systems
    Moradi, Sina
    Liu, Sanly
    Chow, Christopher W. K.
    van Leeuwen, John
    Cooke, David
    Drikas, Mary
    Amal, Rose
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2017, 57 : 170 - 179
  • [5] On-going nitrification in chloraminated drinking water distribution system (DWDS) is conditioned by hydraulics and disinfection strategies
    Shi, Yi
    Babatunde, Akintunde
    Bockelmann-Evans, Bettina
    Li, Qijie
    Zhang, Liang
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2020, 96 : 151 - 162
  • [6] On-going nitrification in chloraminated drinking water distribution system(DWDS) is conditioned by hydraulics and disinfection strategies
    Yi Shi
    Akintunde Babatunde
    Bettina Bockelmann-Evans
    Qijie Li
    Liang Zhang
    Journal of Environmental Sciences, 2020, 96 (10) : 151 - 162
  • [7] Prediction of Pseudomonas aeruginosa abundance in drinking water distribution systems using machine learning
    Zhou, Qiaomei
    Li, Yukang
    Wang, Min
    Huang, Jingang
    Li, Weishuai
    Qiu, Shanshan
    Wang, Haibo
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2025, 193 : 1050 - 1060
  • [8] Effect of free chlorine application on microbial quality of drinking water in chloraminated distribution systems
    Rosenfeldt, Erik J.
    Baeza, Carolina
    Knappe, Detlef R. U.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2009, 101 (10): : 60 - 70
  • [9] Monitoring Adenosine Triphosphate Concentrations in a Chloraminated Drinking Water Distribution System for Risk and Asset Management
    Maal-Bared, Rasha
    McCracken, Michael
    Busawon, Bharatee
    Simpson, Darlyce
    WATER, 2023, 15 (09)
  • [10] Characterization of nitrifying populations in chloraminated drinking water distribution systems by TRFLP analysis.
    Regan, JM
    Harrington, GW
    Noguera, DR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U456 - U456