A versatile and robust electrochemical flow cell with a boron-doped diamond electrode for simultaneous determination of Zn2+ and Pb2+ ions in water samples

被引:0
|
作者
dos Santos, Vagner Bezerra [1 ]
Fava, Elson Luiz [1 ]
Pessoa-Neto, Osmundo Dantas [1 ]
Bianchi, Silmara Rossana [2 ]
Faria, Ronaldo Censi [1 ]
Fatibello-Filho, Orlando [1 ]
机构
[1] Univ Fed Sao Carlos, Ctr Ciencias Exatas & Tecnol, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
[2] Embrapa Solos, Empresa Brasileira Pesquisa Agr, Rio De Janeiro, RJ, Brazil
基金
巴西圣保罗研究基金会;
关键词
STRIPPING VOLTAMMETRIC DETERMINATION; PULSE AMPEROMETRIC DETECTION; INJECTION-ANALYSIS; FILM ELECTRODES; THIN-FILM; MULTICOMMUTATION; SYSTEM;
D O I
10.1039/c4ay01811g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A versatile and robust thermostatted electrochemical flow cell (EFC) with a boron-doped diamond electrode (BDD) detector was employed to perform two distinct flow-injection electrochemical approaches. In the first approach, differential pulse anodic stripping voltammetry (DPASV) using a flow-batch analysis (FBA) is proposed. In the second approach, multiple pulse amperometry (MPA) employing multicommutation flow analysis (MCFA) is also presented. Both approaches were employed to simultaneously determine Zn2+ and Pb2+ in water samples. For this, a screen-printed electrode (SPE) was developed, and a BDD electrode was coupled to it and was inserted into the EFC. By employing the FBA with the DPASV technique, two analytical curves in concentration ranges from 11.5 to 80.6 mu g L-1 and 0.64 to 10.9 mu g L-1 for simultaneous determination of Zn2+ and Pb2+, respectively, were obtained. Moreover, limits of detection (LDs) of 0.62 mu g L-1 and 0.19 mu g L-1 were estimated respectively and a sampling frequency of 12 h(-1) was obtained. For MCFA with MPA, analytical curves from 830 to 4980 mu g L-1 and 140 to 820 mu g L-1 for simultaneous determination of Zn2+ and Pb2+ with LDs of 220.0 mu g L-1 and 41.0 mu g L-1 and a sampling frequency of 67 h(-1) were obtained. The developed EFC allowed a full on-line automation of the methods, covering the pretreatment of BDD, addition of standard solutions, dilutions, thermostatted control, and detection with and without electrochemical preconcentration. In addition, the low waste generation of only 700 mu L may be useful for green chemistry purposes and sustainable research.
引用
收藏
页码:8526 / 8534
页数:9
相关论文
共 50 条
  • [1] Development of a Boron-Doped Diamond Electrode for the Simultaneous Detection of Cd2+ and Pb2+ in Water
    Pei, JingXuan
    Yu, Xiang
    Zhang, Chao
    Liu, XingJu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (04): : 3393 - 3407
  • [2] ELECTROCHEMICAL DETERMINATION OF 2-NAPHTHYLAMINE IN PERFUME SAMPLES USING BORON-DOPED DIAMOND ELECTRODE
    Rodrigues, Guilherme N.
    Silva, Weberson P.
    Rocha, Diego P.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    Batista, Alex D.
    QUIMICA NOVA, 2020, 43 (03): : 286 - 290
  • [3] The Use of Boron-Doped Diamond Electrode for the Determination of Selected Biocides in Water Samples
    Mielech-Lukasiewicz, Katarzyna
    Starczewska, Barbara
    WATER, 2019, 11 (08)
  • [4] Voltammetric determination of erythromycin in water samples using a boron-doped diamond electrode
    Radicova, Monika
    Behul, Miroslav
    Vojs, Marian
    Bodor, Robert
    Stanova, Andrea Vojs
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2015, 252 (11): : 2608 - 2613
  • [5] Electrochemical determination of nitazoxanide in environmental and pharmaceutical samples using a boron-doped diamond electrode
    Oliveira, Ana Clara M.
    Richter, Eduardo M.
    Paixao, Thiago R. L. C.
    Araujo, Diele A. G.
    Munoz, Rodrigo A. A.
    MICROCHEMICAL JOURNAL, 2024, 207
  • [6] Convection control in a flow cell on electrochemical CO2 reduction using a boron-doped diamond electrode
    Nihongi, Shogo
    Otake, Atsushi
    Du, Jinglun
    Einaga, Yasuaki
    CARBON, 2022, 200 : 456 - 461
  • [7] Electrochemical Detection of Pb(Ⅱ) Ions in Aqueous Solution by Carbon Nanospheres Modified Boron-Doped Diamond Electrode
    Nan Wang
    Jiaqi Li
    Yitian Ma
    Ahua Xu
    Huajin Tao
    Baoyu Huang
    Song Hao
    Jianjun Liao
    Shiwei Lin
    Yipeng Tang
    Ying Hou
    Chao Bian
    Xiaogan Li
    Journal of Analysis and Testing, 2024, 8 (04) : 493 - 504
  • [8] Structured and graphitized boron doped diamond electrodes: Impact on electrochemical detection of Cd2+ and Pb2+ ions
    Stenclova, Pavla
    Vyskocil, Vlastimil
    Szabo, Ondrej
    Izak, Tibor
    Potocky, Stepan
    Kromka, Alexander
    VACUUM, 2019, 170
  • [9] Disposable sensors for [Zn2+], [Cd2+] and [Pb2+] determination in natural samples
    Parat, C.
    Authier, L.
    Aguilar, D.
    Companys, E.
    Galceran, J.
    Potin-Gautier, M.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2010, 74 (12) : A791 - A791
  • [10] Voltammetric Determination of Hg2+, Zn2+, and Pb2+ Ions Using a PEDOT/NTA-Modified Electrode
    Alshawi, Jasim M. S.
    Mohammed, Mohammed Q.
    Alesary, Hasan F.
    Ismail, Hani K.
    Barton, Stephen
    ACS OMEGA, 2022, 7 (23): : 20405 - 20419