Effect of a contact lens on mouse retinal in vivo imaging: Effective focal length changes and monochromatic aberrations

被引:34
|
作者
Zhang, Pengfei [1 ]
Mocci, Jacopo [2 ]
Wahl, Daniel J. [3 ]
Meleppat, Ratheesh Kumar [1 ]
Manna, Suman K. [1 ]
Quintavalla, Martino [2 ]
Muradore, Riccardo [4 ]
Sarunic, Marinko, V [3 ]
Bonora, Stefano [2 ]
Pugh Jr, Edward N. [1 ,5 ]
Zawadzki, Robert J. [1 ,5 ]
机构
[1] Univ Calif Davis, Dept Cell Biol & Human Anat, UC Davis Eye Pod Small Anim Ocular Imaging Lab, 4320 Tupper Hall, Davis, CA 95616 USA
[2] CNR, Inst Photon & Nanotechnol, Via Trasea 7, I-35131 Padua, Italy
[3] Simon Fraser Univ, Engn Sci, Burnaby, BC V5A 1S6, Canada
[4] Univ Verona, Dept Comp Sci, Verona, Italy
[5] Univ Calif Davis, Dept Ophthalmol & Vis Sci, UC Davis Eye Ctr, 4860 Y St,Suite 2400, Sacramento, CA 95817 USA
关键词
Contact lens; Effective focal length; Mouse eye aberration; Adaptive optics; Scanning laser ophthalmoscope; OPTICAL COHERENCE TOMOGRAPHY; ADAPTIVE-OPTICS; RESOLUTION; EYE; MODELS; RAT; OCT;
D O I
10.1016/j.exer.2018.03.027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
For in vivo mouse retinal imaging, especially with Adaptive Optics instruments, application of a contact lens is desirable, as it allows maintenance of cornea hydration and helps to prevent cataract formation during lengthy imaging sessions. However, since the refractive elements of the eye (cornea and lens) serve as the objective for most in vivo retinal imaging systems, the use of a contact lens, even with 0 Dpt. refractive power, can alter the system's optical properties. In this investigation we examined the effective focal length change and the aberrations that arise from use of a contact lens. First, focal length changes were simulated with a Zemax mouse eye model. Then ocular aberrations with and without a 0 Dpt. contact lens were measured with a Shack-Hartmann wavefront sensor (SHWS) in a customized AO-SLO system. Total RMS wavefront errors were measured for two groups of mice (14-month, and 2.5-month-old), decomposed into 66 Zernike aberration terms, and compared. These data revealed that vertical coma and spherical aberrations were increased with use of a contact lens in our system. Based on the ocular wavefront data we evaluated the effect of the contact lens on the imaging system performance as a function of the pupil size. Both RMS error and Strehl ratios were quantified for the two groups of mice, with and without contact lenses, and for different input beam sizes. These results provide information for determining optimum pupil size for retinal imaging without adaptive optics, and raise critical issues for design of mouse optical imaging systems that incorporate contact lenses.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 9 条
  • [1] Measuring the effective focal length and the wavefront aberrations of a lens system
    Malacara-Doblado, Daniel
    Patricia Salas-Peimbert, Didia
    Trujillo-Schiaffino, Gerardo
    OPTICAL ENGINEERING, 2010, 49 (05)
  • [2] The effect of contact lens correction and accommodation upon monochromatic higher order aberrations in myopia and hyperopia
    Gray, Lyle S.
    Macfadden, Lucy
    Seidel, Dirk
    I-PERCEPTION, 2011, 2 (04): : 307 - 307
  • [3] On the different ways for defining the effective focal length of a Kerr lens effect
    Leghmizi, S.
    Hasnaoui, A.
    Boubaha, B.
    Aissani, A.
    Ait-Ameur, K.
    LASER PHYSICS, 2017, 27 (10)
  • [4] Cataract-preventing contact lens for in vivo imaging of mouse retina
    Ikeda, Wataru
    Nakatani, Tomoya
    Uemura, Akiyoshi
    BIOTECHNIQUES, 2018, 65 (02) : 101 - 104
  • [5] Effect of Catadioptric Component Postposition on Lens Focal Length and Imaging Surface in a Mirror Binocular System
    Zhou, Fuqiang
    Chen, Yuanze
    Zhou, Mingxuan
    Li, Xiaosong
    SENSORS, 2019, 19 (23)
  • [6] MR in vivo imaging of oxygen suppression effect of soft contact lens on the human cornea
    Saito, K
    Obata, T
    Hirono, K
    Iwasawa, T
    Yoshida, T
    Matsubara, S
    MAGNETIC RESONANCE IMAGING, 2000, 18 (03) : 357 - 360
  • [7] AO-OCT for in vivo mouse retinal imaging: Application of adaptive lens in wavefront sensorless aberration correction
    Bonora, Stefano
    Jian, Yifan
    Pugh, Edward N., Jr.
    Sarunic, Marinko V.
    Zawadzki, Robert J.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [8] Effect of GDNF gene transfer into axotomized retinal ganglion cells using in vivo electroporation with a contact lens-type electrode
    H Ishikawa
    M Takano
    N Matsumoto
    H Sawada
    C Ide
    O Mimura
    M Dezawa
    Gene Therapy, 2005, 12 : 289 - 298
  • [9] Effect of GDNF gene transfer into axotomized retinal ganglion cells using in vivo electroporation with a contact lens-type electrode
    Ishikawa, H
    Takano, M
    Matsumoto, N
    Sawada, H
    Ide, C
    Mimura, O
    Dezawa, M
    GENE THERAPY, 2005, 12 (04) : 289 - 298