Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler

被引:72
|
作者
Brucher, R
Russell, D [1 ]
机构
[1] Natl Hosp Norway, Dept Neurol, N-0027 Oslo, Norway
[2] Univ Appl Sci, Dept Med Engn, Ulm, Germany
关键词
carotid stenosis; cerebral embolism; mechanical heart valve protheses; ultrasonography; Doppler;
D O I
10.1161/01.STR.0000022811.46115.70
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and. Purpose-The goal of this study was to assess the first multifrequency transcranial Doppler system specially developed for online automatic detection of cerebral microemboli. Methods-The multifrequency Doppler instrumentation insonates simultaneously with 2.0- and 2.5-MHz frequencies. The detection threshold for embolus detection used in this study was a relative Doppler energy increase of >20 dB . ms, at which point the Doppler power increase was at least 5 dB and lasted >4 ms above the background energy. Four parameters were used in an optimized binary decision tree to recognize emboli: quarter Doppler shift, maximum duration limit, reference gate, and bidirectional enhancement. In in vitro studies, 200 plastic microspheres (80 mum), 200 gas bubbles (8 to 25 mum), and 600 artifacts were studied in a pulsatile closed-loop system. In vivo studies were carried out for 1 hour in 15 patients with mechanical heart valves and in 45 patients with carotid stenosis. This gave a total of 60 hours of online automatic monitoring in patients. Results-All 400 plastic spheres and microbubbles were automatically detected and correctly classified. Of the 600 artifacts, 596 (99.3%) were correctly classified as artifacts, and 4 (0.7%) were incorrectly identified as emboli (kappa=0.992, P<0.001). The experienced observer detected a total of 554 emboli and 800 artifacts in the heart valve (521 emboli, 400 artifacts) and carotid stenosis (33 emboli, 400 artifacts) patients. With multifrequency Doppler, 546 of these emboli (98.6%) and 791 of these artifacts (98.9%) were automatically detected and correctly classified as embolus or artifact (kappa=0.953, P<0.0001). Conclusions-We found that multifrequency transcranial Doppler had a relatively high sensitivity and specificity when used to automatically detect cerebral microemboli and reject artifacts online.
引用
收藏
页码:1969 / 1974
页数:6
相关论文
共 17 条
  • [1] Embolus detection and differentiation using multifrequency transcranial Doppler
    Russell, D
    Brucher, R
    STROKE, 2006, 37 (02) : 340 - 341
  • [2] Embolus detection and differentiation using multifrequency transcranial Doppler
    Russell, D
    Brucher, R
    STROKE, 2005, 36 (04) : 706 - 706
  • [3] Embolus detection and differentiation using multifrequency transcranial Doppler - Response
    Markus, HS
    Punter, M
    STROKE, 2006, 37 (02) : 341 - 342
  • [4] Embolus differentiation using multifrequency transcranial Doppler
    Evans, David H.
    STROKE, 2006, 37 (07) : 1641 - 1641
  • [5] Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler
    Russell, D
    Brucher, R
    STROKE, 2002, 33 (08) : 1975 - 1980
  • [6] Transcranial Doppler Embolus Detection: A Primer
    Chung, Emma M. L.
    ULTRASOUND, 2006, 14 (04) : 202 - 210
  • [7] A Signal Processing Method for Artefact Rejection in Transcranial Doppler Signals used for Micro-embolus detection
    Geryes, Maroun
    Menigot, Sebastien
    Charara, Jamal
    Skaiky, Ahmad
    Mcheick, Ali
    Girault, Jean-Marc
    2019 FIFTH INTERNATIONAL CONFERENCE ON ADVANCES IN BIOMEDICAL ENGINEERING (ICABME), 2019, : 76 - 79
  • [8] CEREBRAL AIR EMBOLUS DETECTION BY TRANSCRANIAL DOPPLER MONITORING - SWINE MODEL
    NICHOLLS, SC
    GLICKERMAN, D
    LAMB, A
    DETMER, PR
    STROKE, 1993, 24 (03) : 510 - 510
  • [9] TRANSCRANIAL DOPPLER EMBOLUS DETECTION IN ACUTE STROKE - ASSOCIATION WITH ABNORMAL TRANSESOPHAGEAL ECHOCARDIOGRAMS
    OPPENHEIMER, S
    THIEMANN, D
    RAZUMOVSKY, A
    GILLARD, J
    PREZIOSI, T
    LIMA, J
    STROKE, 1994, 25 (01) : 250 - 250
  • [10] Automatic embolus detection compared with human experts - A Doppler ultrasound study
    VanZuilen, EV
    Mess, WH
    Jensen, C
    VanDerTweel, I
    VanGijn, J
    Ackerstaff, RGA
    STROKE, 1996, 27 (10) : 1840 - 1843