Equivalent seismic coefficient in geocell retention systems

被引:51
|
作者
Leshchinsky, Dov [1 ]
Ling, Hoe I. [2 ]
Wang, Jui-Pin [2 ]
Rosen, Arik [3 ]
Mohri, Yoshiyuki [4 ]
机构
[1] Univ Delaware, Dept Civil & Environm Engn, Newark, DE 19716 USA
[2] Columbia Univ, Dept Civil Engn & Engn Mech, New York, NY 10025 USA
[3] PRS Mediterranean, IL-64239 Tel Aviv, Israel
[4] Natl Res Inst Rural Engn, Tsukuba, Ibaraki, Japan
关键词
Geocell; Reinforced soil; Shake table; Seismic slope stability; Seismic reduction factor; WALLS;
D O I
10.1016/j.geotexmem.2008.03.001
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Ideal design of an earthquake resistant earth structure would consider the time records of future seismic events. Objectively, such time records are difficult to predict especially when compared with prediction of the design peak ground acceleration (PGA), a single-value parameter. Furthermore, relevant soil properties are not easily obtainable in the field. Consequently, in routine stability designs, the state of practice utilizing a pseudostatic analysis has not changed for many years. To reduce the inherent conservatism of the pseudostatic approach, it is common to use a fraction of PGA in the stability analysis. For earth structures such as slopes, existing standards suggest a value of this fraction, typically varying between 0.3 and 0.5 times PGA. While one hopes that such values are calibrated against case histories, it is doubtful if there is sufficient field data for a value corresponding to geocell gravity walls and geocell reinforced slopes. Reported here are relevant results of shake table tests on five different geocell structures, each 2.8 m high, subjected to an excitation simulating the Kobe earthquake. Exhumation enabled the tracing of slip surfaces that developed during the shaking. Back-analysis resulted in the fraction of the applied PGA needed to establish a slip surface. The formation of slip surfaces in the context of this work should not be interpreted as collapse or catastrophic failure; rather it signifies the development of an active wedge. Hence, the equivalent coefficients in this work are an upper bound value for the magnitude and intensity of the ground motion applied in the analysis. It was found that for geocell gravity walls, essentially flexible structures, the upper bound seismic coefficient for the applied motion is about 0.4 times PGA. For reinforced geocell walls the upper bound coefficient would be 0.3 times PGA. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:9 / 18
页数:10
相关论文
共 50 条
  • [1] Seismic risk analysis using equivalent nonlinear systems
    Han, SW
    STRUCTURAL SAFETY AND RELIABILITY, VOLS. 1-3, 1998, : 1691 - 1694
  • [2] Seismic Response of Geocell Retaining Walls: Experimental Studies
    Ling, Hoe I.
    Leshchinsky, Dov
    Wang, Jui-Pin
    Mohri, Yoshiyuki
    Rosen, Arik
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2009, 135 (04) : 515 - 524
  • [3] Effect of Facing Slope on the Seismic Response of Geocell Walls
    Latha, Madhavi G.
    Manju, G. S.
    GEOTECHNICAL ENGINEERING, 2018, 49 (01): : 73 - 83
  • [4] Seismic design of outrigger systems using equivalent energy design procedure
    Yang, T. Y.
    Atkinson, Jeremy
    Tobber, Lisa
    Tung, Dorian P.
    Neville, Bob
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (10):
  • [5] Equivalent SDOF systems for the estimation of seismic response of multistory frame structures
    Decanini, L
    Mollaioli, F
    Mura, A
    EARTHQUAKE RESISTANT ENGINEERING STRUCTURES III, 2001, 9 : 101 - 110
  • [6] A percentage equivalent for the coefficient of correlation
    Nygaard, PH
    JOURNAL OF EDUCATIONAL PSYCHOLOGY, 1926, 17 : 86 - 92
  • [7] Equivalent continuum simulations of geocell reinforced sand beds supporting strip footings
    Madhavi Latha G.
    Dash S.K.
    Rajagopal K.
    Geotechnical and Geological Engineering, 2008, 26 (04) : 387 - 398
  • [8] Seismic Response of Geocell Retaining Walls Through Shaking Table Tests
    Madhavi Latha G.
    Manju G.S.
    International Journal of Geosynthetics and Ground Engineering, 2016, 2 (1)
  • [9] An improved equivalent force control algorithm for hybrid seismic testing of nonlinear systems
    Wang, Zhen
    Wu, Bin
    Xu, Guoshan
    Bursi, Oreste S.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (02):
  • [10] EQUIVALENT MODELS OF SEISMIC SOURCES
    JOBERT, G
    JOURNAL OF GEOPHYSICS-ZEITSCHRIFT FUR GEOPHYSIK, 1977, 43 (1-2): : 329 - 339