High-throughput liquid chromatography-tandem mass spectrometry determination of bupropion and its metabolites in human, mouse and rat plasma using a monolithic column

被引:66
|
作者
Borges, V
Yang, E
Dunn, J
Henion, J
机构
[1] Cornell Univ, Dept Populat Med & Diagnost Sci, Ithaca, NY 14850 USA
[2] GlaxoSmithKline Pharm, DMPK, Worldwide Bioanal, Res Triangle Pk, NC 27709 USA
关键词
bupropion; hydroxybupropion; threo-hydrobupropion;
D O I
10.1016/j.jchromb.2004.01.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work, a high-throughput LC/MS/MS method using a Chromolith RP-18 (50 mm x 4.6 mm) monolithic column was developed and partially validated for the determination of bupropion (BUP), an anti-depressant drug, and its metabolites, hydroxybupropion and threo-hydrobupropion (TB), in human, mouse, and rat plasma. A modem integrated liquid chromatograph and an LC/MS/MS system with a TurboIonSpray (TIS) interface were used for the positive electrospray selected reaction monitoring (SRM) LC/MS analyses. Spiked control plasma calibration standards and quality control (QC) samples were extracted by semi-automated 96-well liquid-liquid extraction (LLE) using ethyl acetate. A mobile phase consisting of 8 mM ammonium acetate-acetonitrile (55:45, v/v) delivered isocratically at 5 ml/min, and split post-column to 2 ml/min directed to the TIS, provided the optimum conditions for the chromatographic separation of bupropion and its metabolites within 23 s. The isotope-labeled D-6-bupropion and D-6-hydroxybupropion were used as internal standards. The method was linear over a concentration range of 0.25-200 ng/ml (bupropion and threo-hydrobupropion), and 1.25-1000 ng/ml (hydroxybupropion). The intra- and inter-day assay accuracy and precision were within 15% for all analytes in each of the biological matrices. The monolithic column performance as a function of column backpressure, peak asymmetry, and retention time reproducibility was adequately maintained over 864 extracted plasma injections. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:277 / 287
页数:11
相关论文
共 50 条
  • [1] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (06) : 436 - 445
  • [2] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (08) : 591 - 600
  • [3] High-throughput liquid chromatography-tandem mass spectrometry assay for plasma theophylline and its metabolites
    Song, J
    Park, KU
    Park, HD
    Yoon, Y
    Kim, JQ
    CLINICAL CHEMISTRY, 2004, 50 (11) : 2176 - 2179
  • [4] High-throughput plasma docetaxel quantification by liquid chromatography-tandem mass spectrometry
    Corona, Giuseppe
    Elia, Caterina
    Casetta, Bruno
    Frustaci, Sergio
    Toffoli, Giuseppe
    CLINICA CHIMICA ACTA, 2011, 412 (3-4) : 358 - 364
  • [5] Simultaneous determination of triazolam and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    Pan, Ryh-Nan
    Lin, Chang-Ching
    Huang, Pei-Wei
    Hsiong, Cheng-Huei
    Pao, Li-Heng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 872 (1-2): : 58 - 62
  • [6] High-speed liquid chromatography/tandem mass spectrometry using a monolithic column for high-throughput bioanalysis
    Wu, JT
    Zeng, H
    Deng, YZ
    Unger, SE
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (13) : 1113 - 1119
  • [7] Simultaneous determination of ivabradine and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    François-Bouchard, M
    Simonin, G
    Bossant, MJ
    Boursier-Neyret, C
    JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (02): : 261 - 269
  • [8] Simultaneous Determination of Ticagrelor and Its Metabolites in Human Plasma and Urine Using Liquid Chromatography-Tandem Mass Spectrometry
    Zhong, Wanping
    Wang, Xipei
    Tang, Lan
    Mai, Liping
    Chen, Xiao-Ping
    He, Guodong
    Zheng, Zhijie
    Zhong, Shilong
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (06) : 445 - 453
  • [9] A simple high-throughput method for the determination of plasma methylmalonic acid by liquid chromatography-tandem mass spectrometry
    Blom, Henk J.
    van Rooij, Arno
    Hogeveen, Marije
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (05) : 645 - 650
  • [10] Development of a high-throughput liquid chromatography-tandem mass spectrometry platform for the determination of intact natriuretic peptides in human plasma
    Lenzi, Alessio
    De Cristofaro, Mariano
    Biagini, Denise
    Ghimenti, Silvia
    Armenia, Silvia
    Pugliese, Nicola R.
    Masi, Stefano
    Di Francesco, Fabio
    Lomonaco, Tommaso
    TALANTA, 2024, 275