2D-GRAPPA-operator for faster 3D parallel MRI

被引:71
|
作者
Blaimer, Martin
Breuer, Felix A.
Mueller, Matthias
Seiberlich, Nicole
Ebel, Dmitry
Heidemann, Robin M.
Griswold, Mark A.
Jakob, Peter M.
机构
[1] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Cleveland, OH 44106 USA
关键词
3D MRI; phased array; parallel imaging; GRAPPA; GRAPPA-operator;
D O I
10.1002/mrm.21071
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
When using parallel MRI (pMRI) methods in combination with three-dimensional (3D) imaging, it is beneficial to subsample the k-space along both phase-encoding directions because one can then take advantage of coil sensitivity variations along two spatial dimensions. This results in an improved reconstruction quality and therefore allows greater scan time reductions as compared to subsampling along one dimension. In this work we present a new approach based on the generalized autocalibrating partially parallel acquisitions (GRAPPA) technique that allows Fourier-domain reconstructions of data sets that are subsampled along two dimensions. The method works by splitting the 2D reconstruction process into two separate 1D reconstructions. This approach is compared with an extension of the conventional GRAPPA method that directly regenerates missing data points of a 2D subsampled k-space by performing a linear combination of acquired data points. In this paper we describe the theoretical background and present computer simulations and in vivo experiments.
引用
收藏
页码:1359 / 1364
页数:6
相关论文
共 50 条
  • [1] 2D sense for faster 3D MRI
    Markus Weiger
    Klaas P. Pruessmann
    Peter Boesiger
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2002, 14 (1) : 10 - 19
  • [2] 2D SENSE for faster 3D MRI
    Weiger, M
    Pruessmann, KP
    Boesiger, P
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 14 (01): : 10 - 19
  • [3] Performance Analysis of 2-D GRAPPA and Partial Fourier GRAPPA for 3-D MRI
    Shan He
    Guoxi Xie
    Yiu-Cho Chung
    Yu Ding
    Xin Liu
    Bensheng Qiu
    Applied Magnetic Resonance, 2013, 44 : 1199 - 1212
  • [4] Performance Analysis of 2-D GRAPPA and Partial Fourier GRAPPA for 3-D MRI
    He, Shan
    Xie, Guoxi
    Chung, Yiu-Cho
    Ding, Yu
    Liu, Xin
    Qiu, Bensheng
    APPLIED MAGNETIC RESONANCE, 2013, 44 (10) : 1199 - 1212
  • [5] 3D BPCONVNET TO RECONSTRUCT PARALLEL MRI
    Jin, Kyong Hwan
    Unser, Michael
    2018 IEEE 15TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2018), 2018, : 361 - 364
  • [6] 3D: FASTER AND BIGGER
    Brown, Alan S.
    MECHANICAL ENGINEERING, 2019, 141 (09) : 24 - 25
  • [7] Self-calibrated GRAPPA method for 2D and 3D radial data
    Arunachalam, Arjun
    Samsonov, Alexey
    Block, Walter F.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (05) : 931 - 938
  • [8] A 2D-GRAPPA Algorithm with a Boomerang Kernel for 3D MRI Data Accelerated along Two Phase-Encoding Directions
    Shin, Seonyeong
    Han, Yeji
    Chung, Jun-Young
    SENSORS, 2023, 23 (01)
  • [9] Dilatation operator in 3d
    Sochichiu, Corneliu
    JOURNAL OF HIGH ENERGY PHYSICS, 2009, (03):
  • [10] Fast 3D Volumetric Image Reconstruction from 2D MRI Slices by Parallel Processing
    Somoballi Ghoshal
    Shreemoyee Goswami
    Amlan Chakrabarti
    Susmita Sur-Kolay
    SN Computer Science, 5 (8)