Comparison between liquid chromatography and supercritical fluid chromatography coupled to mass spectrometry for beta-agonists screening in feeding stuff

被引:12
|
作者
Herpin, L. [1 ]
Bichon, E. [1 ]
Rambaud, L. [1 ]
Monteau, F. [1 ]
Le Bizec, B. [1 ]
机构
[1] INRA, UMR 1329, LABERCA, LUNAM,Oniris, Nantes, France
关键词
beta-agonists; UHPLC-MS/MS; SFC-MS/MS; Feeding stuff; Growth promoters monitoring; SOLID-PHASE EXTRACTION; GAS-CHROMATOGRAPHY; CLENBUTEROL RESIDUES; IMPRINTED-POLYMERS; PERFORMANCE; URINE; RACTOPAMINE; IDENTIFICATION; SALBUTAMOL; DEPOSITION;
D O I
10.1016/j.jchromb.2018.04.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
beta-agonistic drugs have been forbidden as growth promoters in rearing animals in Europe since the late 1980s (Dir 96/22/EC). Specific and sensitive analytical methods based on UHPLC-MS/MS allow to monitor a large set of these substances. However, optimal performances are not observed for all the target analytes, especially for those exhibiting the highest polarities. We developed an SFC-MS/MS approach to cover the huge elution window of beta-agonists, from the most polar which are usually eluted in the void volume when using reversed phase chromatography in conventional HPLC to the most apolar ones. The objective was to reach performances in accordance with the European Union recommended level in feeding stuff, i.e. 50 mu g kg(-1). LC/MS and SFC/MS performances were thoroughly compared in terms of analytical validation data (linearity, selectivity, recovery rates, reproducibility, compounds identification, trueness, decision limit (CC alpha) and detection capability (CC beta) for 6 beta-agonistic drugs, namely bromobuterol, clenbuterol, isoxsuprine, ractopamine, salbutamol and zilpaterol. As a result, the SFC approach appeared complementary to the LC one because the elution order of compounds was totally different from the one obtained with a classical C18 stationary phase. Moreover, the UPLC-MS/MS approach gave a better response linearity and more accurate values, whereas SFC-MS/MS provided greater data for identification purposes, reproducibility and sensitivity. Both analytical approaches enabled the detection of targeted beta-agonists at a lower concentration than the recommended one (50 mu g kg(-1)).
引用
收藏
页码:130 / 137
页数:8
相关论文
共 50 条
  • [1] Gas and liquid chromatography coupled to tandem mass spectrometry for the multiresidue analysis of beta-agonists in biological matrices
    VanVyncht, G
    Preece, S
    Gaspar, P
    MaghuinRogister, G
    DePauw, E
    JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) : 43 - 49
  • [2] Development of supercritical fluid chromatography coupled with mass spectrometry method for characterization of a nonionic surfactant and comparison with liquid chromatography coupled with mass spectrometry method
    Pan, Jinheng
    Tang, Yan
    Shen, Zhengchao
    Du, Zhenxia
    JOURNAL OF MASS SPECTROMETRY, 2020, 55 (05):
  • [3] COMPARISON OF VARIOUS HYPHENATED CHROMATOGRAPHY - MASS-SPECTROMETRY METHODS FOR THE ANALYSIS OF BETA-AGONISTS
    DEBRAUWER, L
    DELOUS, G
    BORIES, G
    CHROMATOGRAPHIA, 1993, 36 : 218 - 224
  • [4] Supercritical fluid chromatography coupled to mass spectrometry for lipidomics
    Chollet, Celine
    Boutet-Mercey, Stephanie
    Laboureur, Laurent
    Rincon, Carlos
    Mejean, Marie
    Jouhet, Juliette
    Fenaille, Francois
    Colsch, Benoit
    Touboul, David
    JOURNAL OF MASS SPECTROMETRY, 2019, 54 (10): : 791 - 801
  • [5] Supercritical fluid chromatography coupled to mass spectrometry - A metabolomics perspective
    Shulaev, Vladimir
    Isaac, Giorgis
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1092 : 499 - 505
  • [6] Determination of Four Beta-Agonists Residues in Products of Animal Origin and Urine by Ultra Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry
    Wang Feng-Mei
    Zhang Hong-Wei
    Pang Shi-Ping
    Tang Zhi-Xu
    Niu Zeng-Yuan
    Luo Xin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (12) : 1629 - 1635
  • [7] CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY AND SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY
    SMITH, RD
    WRIGHT, BW
    UDSETH, HR
    ACS SYMPOSIUM SERIES, 1986, 297 : 260 - 293
  • [8] Determination of fifteen beta-agonists in animal urine by high performance liquid chromatography-tandem mass spectrometry
    Nie Jianrong
    Zhu Mingli
    Lian Jin
    Pan Yunshan
    Deng Xianglian
    Hu Cuiping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (08) : 759 - 764
  • [9] Systematic evaluation of matrix effects in supercritical fluid chromatography versus liquid chromatography coupled to mass spectrometry for biological samples
    Desfontaine, Vincent
    Capetti, Francesca
    Nicoli, Raul
    Kuuranne, Tiia
    Veuthey, Jean-Luc
    Guillarme, Davy
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1079 : 51 - 61
  • [10] Liquid chromatography versus supercritical fluid chromatography coupled to mass spectrometry: a comparative study of performance for multiresidue analysis of pesticides
    Cutillas, Victor
    Ferrer, Carmen
    Fernandez-Alba, Amadeo R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (23) : 5849 - 5857