QEMSCAN as a Method of Semi-Automated Crystal Size Distribution Analysis: Insights from Apollo 15 Mare Basalts

被引:8
|
作者
Bell, S. K. [1 ]
Joy, K. H. [1 ]
Pernet-Fisher, J. F. [1 ]
Hartley, M. E. [1 ]
机构
[1] Univ Manchester, Dept Earth & Environm Sci, Manchester M13 9PL, Lancs, England
基金
英国科学技术设施理事会;
关键词
crystal size distribution; QEMSCAN; Apollo; 15; mare basalt; quantitative petrology; QUANTITATIVE TEXTURAL ANALYSIS; MAGMA SOLIDIFICATION PROCESSES; DISTRIBUTION CSD; KILAUEA VOLCANO; ERUPTION; OLIVINE; CRYSTALLIZATION; PETROGENESIS; PLAGIOCLASE; DYNAMICS;
D O I
10.1093/petrology/egaa047
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Crystal size distribution analysis is a non-destructive, quantitative method providing insights into the crystallization histories of magmas. Traditional crystal size distribution data collection requires the manual tracing of crystal boundaries within a sample from a digital image. Although this manual method requires minimal equipment to perform, the process is often time-intensive. In this study we investigate the feasibility of using the Quantitative Evaluation of Minerals by SCANing electron microscopy (QEMSCAN) software for semi-automated crystal size distribution analysis. Four Apollo 15 mare basalt thin sections were analysed using both manual and QEMSCAN crystal size distribution data collection methods. In most cases we observe an offset between the crystal size distribution plots produced by QEMSCAN methods compared with the manual data, leading to differences in calculated crystal residence times and nucleation densities. The source of the discrepancy is two-fold: (1) the touching particles processor in the QEMSCAN software is prone to segmenting overlapping elongate crystals into multiple smaller crystals; (2) this segmentation of elongate crystals causes estimates of true 3D crystal habit to vary between QEMSCAN and manual data. The reliability of the QESMCAN data appears to be a function of the crystal texture and average crystal shape, both of which influence the performance of the touching particles processor. Despite these limitations, QEMSCAN is able to produce broadly similar overall trends in crystal size distribution plots to the manual approach, in a considerably shorter time frame. If an accurate crystal size distribution is required to calculate crystal residence time or nucleation density, we recommend that QEMSCAN should only be used after careful consideration of the suitability of the sample texture and average crystal shape.
引用
收藏
页数:20
相关论文
共 8 条
  • [1] Grain-size analysis of mudrocks: A new semi-automated method from SEM images
    Bankole, Shereef A.
    Buckman, Jim
    Stow, Dorrik
    Lever, Helen
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2019, 174 : 244 - 256
  • [2] A RAPID SEMI-AUTOMATED MICROTITER PLATE METHOD FOR ANALYSIS AND SEQUENCING BY PCR FROM BACTERIAL STOCKS
    SCHOFIELD, JP
    VAUDIN, M
    KETTLE, S
    JONES, DSC
    NUCLEIC ACIDS RESEARCH, 1989, 17 (22) : 9498 - 9498
  • [3] Advancing modular construction through circular economy: Insights from semi-automated PRISMA analysis and topic modeling
    Ly, Dang Huy
    Le, Quang Hoai
    Nguyen, Truong Dang Hoang Nhat
    Ahn, Yonghan
    Kim, Kyungsoo
    Kwon, Nahyun
    JOURNAL OF BUILDING ENGINEERING, 2024, 98
  • [4] Crystallization of the basaltic shergottites: Insights from crystal size distribution (CSD) analysis of pyroxenes
    Lentz, RCF
    McSween, HY
    METEORITICS & PLANETARY SCIENCE, 2000, 35 (05): : 919 - 927
  • [5] Identification and Counting of European Souslik Burrows from UAV Images by Pixel-Based Image Analysis and Random Forest Classification: A Simple, Semi-Automated, yet Accurate Method for Estimating Population Size
    Gedeon, Csongor, I
    Arvai, Matyas
    Szatmari, Gabor
    Brevik, Eric C.
    Takats, Tunde
    Kovacs, Zsofia A.
    Meszaros, Janos
    REMOTE SENSING, 2022, 14 (09)
  • [6] VALUE STREAM MAPPING AND ANALYSIS OF THE QUALITY PARAMETERS FROM THE CONTROL UNITS PROCESSED USING A SEMI-AUTOMATED, BUFFY COAT METHOD, IN A COLOMBIAN BLOOD BANK CENTER
    Comasolivas, N.
    Manrique-Salamanca, C.
    Perez-Carrillo, J. A.
    VALUE IN HEALTH, 2023, 26 (06) : S306 - S306
  • [7] A Semi-Automated Molecularly Imprinted Polymer Solid-Phase Extraction Method for Catechin Analysis from Jaboticaba (Plinia sp.) Peel Extract Samples by UHPLC-DAD
    Cardoso, Alessandra T.
    Martins, Rafael O.
    Machado, Lucas S.
    Kato, Lucilia
    Simas, Rosineide C.
    Cardoso, Carmen Lucia
    Chaves, Andrea R.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2024, 35 (09)
  • [8] A semi-automated method using object-based image analysis (OBIA) to detect and enumerate beluga whales in summer from very high-resolution (VHR) satellite imagery
    Iacozza, John
    Sherbo, Bryanna
    Watt, Cortney
    PLOS ONE, 2024, 19 (11):