ECG Parameters and Exposure to Carbon Ultrafine Particles in Young Healthy Subjects

被引:30
|
作者
Zareba, Wojciech [1 ]
Couderc, Jean Philippe [1 ]
Oberdorster, Gunter [2 ]
Chalupa, David [1 ]
Cox, Christopher [3 ]
Huang, Li-Shan [4 ]
Peters, Annette [5 ]
Utell, Mark J. [1 ]
Frampton, Mark W. [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Med, Rochester, NY 14642 USA
[2] Univ Rochester, Med Ctr, Dept Environm Med, Rochester, NY 14642 USA
[3] Johns Hopkins Univ, Bloomberg Sch Publ Hlth, Dept Epidemiol, Baltimore, MD USA
[4] Univ Rochester, Med Ctr, Dept Biostat & Computat Biol, Rochester, NY 14642 USA
[5] German Res Ctr Environm Hlth, Helmholtz Zentrum Munchen, Neuherberg, Germany
基金
美国国家卫生研究院;
关键词
HEART-RATE-VARIABILITY; PARTICULATE AIR-POLLUTION; MYOCARDIAL-INFARCTION; AUTONOMIC DYSFUNCTION; ASTHMATIC VOLUNTEERS; LOS-ANGELES; DISEASE; INFLAMMATION; MECHANISMS; INHALATION;
D O I
10.1080/08958370802492407
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The mechanisms underlying the association between air pollution and cardiovascular morbidity and mortality are unknown. This study aimed to determine whether controlled exposure to elemental carbon ultrafine particles (UFP) affects electrocardiogram (ECG) parameters describing heart rate variability; repolarization duration, morphology, and variability; and changes in the ST segment. Two separate controlled studies (12 subjects each) were performed using a crossover design, in which each subject was exposed to filtered air and carbon UFP for 2 hours. The first protocol involved 2 exposures to air and 10 g/m3 ( 2 106 particles/cm3, count median diameter 25 nm, geometric standard deviation 1.6), at rest. The second protocol included 3 exposures to air, 10, and 25 g/m3 UFP ( 7 106 particles/cm3), with repeated exercise. Each subject underwent a continuous digital 12-lead ECG Holter recording to analyze the above ECG parameters. Repeated measures analysis of variance (ANOVA) was used to compare tested parameters between exposures. The observed responses to UFP exposure were small and generally not significant, although there were trends indicating an increase in parasympathetic tone, which is most likely also responsible for trends toward ST elevation, blunted QTc shortening, and increased variability of T-wave complexity after exposure to UFP. Recovery from exercise showed a blunted response of the parasympathetic system after exposure to UFP in comparison to air exposure. In conclusion, transient exposure to 10-25 g/m3 ultrafine carbon particles does not cause marked changes in ECG-derived parameters in young healthy subjects. However, trends are observed indicating that some subjects might be susceptible to air pollution, with a response involving autonomic modulation of the heart and repolarization of the ventricular myocardium.
引用
收藏
页码:223 / 233
页数:11
相关论文
共 50 条
  • [1] Effect of inhaled carbon ultrafine particles on reactive hyperemia in healthy human subjects
    Shah, Alpa P.
    Pietropaoli, Anthony A.
    Frasier, Lauren M.
    Speers, Donna M.
    Chalupa, David C.
    Delehanty, Joseph M.
    Huang, Li-Shan
    Utell, Mark J.
    Frampton, Mark W.
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2008, 116 (03) : 375 - 380
  • [2] Cardiopulmonary Effects of Ambient Ultrafine Particles in Healthy Subjects
    Lee, S. M.
    Chalupa, D. C.
    Frasier, L. M.
    Little, E. L.
    Oberdorster, G.
    Pietropaoli, A. P.
    Stewart, J. C.
    Utell, M. J.
    Frampton, M. W.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [3] Airway and systemic inflammatory responses to ultrafine carbon black particles and ozone in older healthy subjects
    Holz, Olaf
    Heusser, Karsten
    Mueller, Meike
    Windt, Horst
    Schwarz, Katharina
    Schindler, Christoph
    Tank, Jens
    Hohlfeld, Jens M.
    Jordan, Jens
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2018, 81 (13): : 576 - 588
  • [4] Effects of the exposure to ultrafine particles on heart rate in a healthy population
    Rizza, Valeria
    Stabile, Luca
    Vistocco, Domenico
    Russi, Aldo
    Pardi, Stefano
    Buonanno, Giorgio
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 650 : 2403 - 2410
  • [5] Short-term inhalation exposure of healthy and compromised rats and mice to fine and ultrafine carbon particles
    Arts, JHE
    Spoor, SM
    Muijser, H
    INHALATION TOXICOLOGY, 2000, 12 : 261 - 266
  • [6] WORKER EXPOSURE TO ULTRAFINE PARTICLES DURING CARBON BLACK TREATMENT
    Mikolajczyk, Urszula
    Bujak-Pietrek, Stella
    Szadkowska-Stanczyk, Irena
    MEDYCYNA PRACY, 2015, 66 (03) : 317 - 326
  • [7] Pulmonary responses of acute exposure to ultrafine iron particles in healthy adult rats
    Zhou, YM
    Zhong, CY
    Kennedy, IM
    Pinkerton, KE
    ENVIRONMENTAL TOXICOLOGY, 2003, 18 (04) : 227 - 235
  • [8] Personal exposure to ultrafine particles
    Lance Wallace
    Wayne Ott
    Journal of Exposure Science & Environmental Epidemiology, 2011, 21 : 20 - 30
  • [9] Personal exposure to ultrafine particles
    Wallace, Lance
    Ott, Wayne
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2011, 21 (01) : 20 - 30
  • [10] Skin inflammation and psoriasis may be linked to exposure of ultrafine carbon particles
    Huyan Xiao
    Hongquan Zhang
    Journal of Environmental Sciences, 2020, 96 (10) : 206 - 208