Determination of Pb(II) with a dithizone-modified carbon paste electrode

被引:7
|
作者
Vazquez, Ma Dolores [1 ]
Tascon, Ma Luz [1 ]
Deban, Luis [1 ]
机构
[1] Univ Valladolid, Dept Analyt Chem, Fac Sci, E-47005 Valladolid, Spain
关键词
dithizone; chemically modified carbon paste electrode; differential pulse anodic stripping voltammetry; lead determination;
D O I
10.1080/10934520600966433
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A dithizone (DTZ) modified carbon paste electrode was developed for the sensitive and selective determination of Pb(II) using differential pulse anodic stripping voltammetry as well in batch as in FIA system. The analysis procedure is based on an open circuit accumulation step in a stirred sample solution. This was followed by a medium exchange to a clean solution and subsequently by a proper anodic stripping. The analytical performance was evaluated with respect to the quantity of modifier in the paste, accumulation time, background electrolyte, Pb(II) concentration and other variables. When the accumulation time applied was 5 minutes, linear calibration graphs were obtained in the concentration range 1 x 10(-7)-1 x 10(-5) M and 8 x 10(-8)-5 x 10(-6) M for batch and Flow Injection Analysis (FIA), respectively. The detection limits found were 8.65 x 10(-8) M in batch and 4.45 x 10(-8) M in FIA. A convenient and rapid renewal of electrode surface allows the use of a single modified electrode surface in multiple analytical determinations. Several coexisting metals ions such as Cd(II), Hg(II), Cu(II) and Zn(II) had no interference on the determination of Pb(II). The proposed method was applied in the determination of lead in soils located in the vicinity of metallurgic transformation industry. The results obtained were in accordance to the ones supplied by Atomic Absorption Spectroscopy (AAS).
引用
收藏
页码:2735 / 2746
页数:12
相关论文
共 50 条
  • [1] VOLTAMMETRIC BEHAVIOR OF GOLD AT A DITHIZONE-MODIFIED CARBON-PASTE ELECTRODE
    KALCHER, K
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 325 (02): : 181 - 185
  • [2] Determination of mercury at a dithizone-modified glassy carbon electrode by anodic stripping voltammetry
    Huang, WS
    Zhang, SH
    ANALYTICAL SCIENCES, 2002, 18 (02) : 187 - 189
  • [3] Determination of Mercury at a Dithizone-Modified Glassy Carbon Electrode by Anodic Stripping Voltammetry
    Wensheng Huang
    Shenghui Zhang
    Analytical Sciences, 2002, 18 : 187 - 189
  • [4] Anodic stripping voltammetric determination of Cd2+ and Pb2+ using dithizone-modified glassy carbon electrode
    Huang, WS
    Yang, CH
    Zhang, SH
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (11) : 1367 - 1370
  • [5] Voltammetric Determination of Pb(II) Ions at a Modified Kaolinite-Carbon Paste Electrode
    Akanji, Seyi P.
    Arotiba, Omotayo A.
    Nkosi, Duduzile
    ELECTROCATALYSIS, 2019, 10 (06) : 643 - 652
  • [6] Voltammetric Determination of Pb(II) Ions at a Modified Kaolinite-Carbon Paste Electrode
    Seyi P. Akanji
    Omotayo A. Arotiba
    Duduzile Nkosi
    Electrocatalysis, 2019, 10 : 643 - 652
  • [7] Voltammetric determination of Pb (II) ions by Carbon Paste Electrode modified with Lemon grass powder
    Rajawat, D. S.
    Satsangee, S. P.
    RESEARCH JOURNAL OF CHEMISTRY AND ENVIRONMENT, 2011, 15 (03): : 55 - 59
  • [8] Naphthazarin modified carbon paste electrode for determination of copper(II)
    Chaisuksant, Rasamee
    Pattanarat, Lertnapa
    Grudpan, Kate
    MICROCHIMICA ACTA, 2008, 162 (1-2) : 181 - 188
  • [9] Naphthazarin modified carbon paste electrode for determination of copper(II)
    Rasamee Chaisuksant
    Lertnapa Pattanarat
    Kate Grudpan
    Microchimica Acta, 2008, 162 : 181 - 188
  • [10] Ion Exchange Resin Modified Carbon Paste Electrode Applied to Simultaneous Determination of Cd (II) and Pb (II)
    de Almeida, Leandro Silva
    Maciel, Juliana Villela
    Sant'Anna Cadaval Junior, Tito Roberto
    Dias, Daiane
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (02)