Direct RP-HPLC determination of underivatized amino acids with online dual UV absorbance, fluorescence, and multiple electrochemical detection

被引:27
|
作者
Agrafiotou, Panagiota [1 ]
Sotiropoulos, Sotiris [1 ]
Pappa-Louisi, Adriani [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Phys Chem Lab, Thessaloniki 54124, Greece
关键词
Dual electrode; Microdisc electrode; Multiple UV-fluorescence-electrochemical detection; Reversed phase liquid chromatography (RPLC); Underivatized amino acids and related compounds; PERFORMANCE LIQUID-CHROMATOGRAPHY; LIGHT-SCATTERING DETECTION; AMPEROMETRIC DETECTION; BLOOD SPOTS; THIOLS; OPTIMIZATION; HOMOCYSTEINE; QUANTITATION; DISULFIDES; SAMPLES;
D O I
10.1002/jssc.200800636
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combined use of a dual-UV detector, a fluorimetric one and of a multiple electrochemical (EC) detector equipped with a dual electrode, consisting of a conventional size 3 mm diameter glassy carbon electrode (GCE) and of a pair of 30 Pin thick carbon microfibers, is proposed for the determination of 15 amino acids, two dipeptides and creatinine. This online coupling of the above detection modes could partially replace amino acid analysis by derivatization methods, since it solves problems concerning the direct detection of selected underivatized amino acids. Additionally, it was proved that the use of multiple-detection allows positive peak identification in a single chromatographic run, yields more information for free amino acids and solves in some cases the problem of chromatographic resolution. In order to optimize the detection conditions of the underivatized amino acids and related compounds by different detectors, their detection characteristics were determined by adequate preliminary experiments. The electro-oxidation characteristics of the underivatized compounds of interest were determined by hydrodynamic voltammetry using a flow cell with a macrodisc GCE and by ex-situ voltammetry using both a GCE of conventional size and a carbon fiber disk microelectrode. Important practical advantages of microfiber and microdisk electrodes with respect to macroelectrodes were demonstrated.
引用
收藏
页码:949 / 954
页数:6
相关论文
共 50 条
  • [1] Evaluation of Suwannee River NOM electrophoretic fractions by RP-HPLC with online absorbance and fluorescence detection
    Trubetskaya, Olga E.
    Richard, Claire
    Trubetskoj, Oleg A.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (13) : 9989 - 9998
  • [2] Evaluation of Suwannee River NOM electrophoretic fractions by RP-HPLC with online absorbance and fluorescence detection
    Olga E. Trubetskaya
    Claire Richard
    Oleg A. Trubetskoj
    Environmental Science and Pollution Research, 2015, 22 : 9989 - 9998
  • [3] ESTROGENS DETERMINATION IN URINE BY RP-HPLC WITH UV DETECTION
    TIRENDI, S
    LANCETTA, T
    BOUSQUET, E
    FARMACO, 1994, 49 (06): : 427 - 430
  • [4] Direct UV detection of underivatized amino acids using capillary electrophoresis with online sweeping enrichment
    Jiang, Xuemei
    Xia, Zhining
    Wei, Weili
    Gou, Qian
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (11) : 1927 - 1933
  • [5] Determination of amino acids in interstitial water by dialysis and RP-HPLC
    Ianni, C
    Baffi, F
    Magi, E
    ANNALI DI CHIMICA, 2000, 90 (7-8) : 435 - 441
  • [6] Determination of underivatized long chain fatty acids using RP-HPLC with capacitively coupled contactless conductivity detection
    Makahleh, Ahmad
    Saad, Bahruddin
    Siang, Gan Hui
    Saleh, Muhammad Idiris
    Osman, Hasnah
    Salleh, Baharuddin
    TALANTA, 2010, 81 (1-2) : 20 - 24
  • [7] Mammalian metallothionein sub-isoform separation by RP-HPLC with online UV and electrochemical detection
    Bordin, G
    Raposo, FC
    Rodriguez, A
    METALLOTHIONEIN IV, 1999, : 73 - 84
  • [8] ELECTROCHEMICAL DETECTION AS AN ALTERNATIVE TO UV IN RP-HPLC PEPTIDE-MAPPING
    CHEN, L
    KRULL, IS
    ELECTROANALYSIS, 1994, 6 (01) : 1 - 8
  • [9] An HPLC detection scheme for underivatized amino acids based on tryptophan fluorescence recovery
    Yang, M
    Tomellini, SA
    ANALYTICA CHIMICA ACTA, 2000, 409 (1-2) : 45 - 53
  • [10] Isocratic ion chromatographic determination of underivatized amino acids by electrochemical detection
    Casella, IG
    Contursi, M
    ANALYTICA CHIMICA ACTA, 2003, 478 (02) : 179 - 189