Scanning analysis of REE in bastnaesite with synchrotron radiation X-ray fluorescence microprobe

被引:0
|
作者
An, QX
Wang, RB
Deng, SW
Pan, JX
Wu, YR
Wu, CY
机构
[1] NATL RES CTR GEOANAL,BEIJING 100037,PEOPLES R CHINA
[2] INST HIGH ENERGY PHYS,BEIJING 100039,PEOPLES R CHINA
[3] CHINESE ACAD GEOL SCI,INST MINERAL DEPOSITS,BEIJING 100037,PEOPLES R CHINA
关键词
synchrotron radiation X-ray fluorescence; rare earth analysis; bastnaesite;
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The content of REE(La, Ce, Pr, Nd, Sm) in bastnaesite was measured by synchrotron radiation X-ray fluorescence microprobe. Scanning analysis makes use of excitation of the REE K lines between 33 and 50 keV. SR white beam from a Wiggler source at the Beijing Electron Positron Collider(BEPC) of the National Laboratory, in order to excite the REE. The bastnaesite from the same mineral area was powdered to particle size less than or equal to 300 mesh. It was then divided into two parts. One portion was used to be determined by XRF after depositing with oxalate and transforming into oxide. The other was pressed into disk without any binder as the reference sample. The weight and the diameter of the disk were 15 g and 26 mm respectively.
引用
收藏
页码:308 / 311
页数:4
相关论文
共 50 条
  • [1] Scanning Analysis of REE in Bastnaesite with Synchrotron Radiation X-Ray Fluorescence Microprobe
    安庆骧
    王锐兵
    邓赛文
    潘巨祥
    吴应荣
    吴澄宇
    JournalofRareEarths, 1996, (04) : 308 - 311
  • [2] SCANNING X-RAY FLUORESCENCE MICROPROBE WITH SYNCHROTRON RADIATION.
    Gohshi, Yohichi
    Aoki, Sadao
    Iida, Atsuo
    Hayakawa, Shinjiro
    Yamaji, Hironao
    Sakurai, Kenji
    Japanese Journal of Applied Physics, Part 2: Letters, 1987, 26 (08): : 1260 - 1262
  • [3] Fast scanning X-ray microprobe fluorescence imaging based on synchrotron radiation
    Yan Fen
    Zhang Ji-Chao
    Li Ai-Guo
    Yang Ke
    Wang Hua
    Mao Cheng-Wen
    Liang Dong-Xu
    Yan Shuai
    Li Jiong
    Yu Xiao-Han
    ACTA PHYSICA SINICA, 2011, 60 (09)
  • [4] A SCANNING-X-RAY FLUORESCENCE MICROPROBE WITH SYNCHROTRON RADIATION
    GOHSHI, Y
    AOKI, S
    IIDA, A
    HAYAKAWA, S
    YAMAJI, H
    SAKURAI, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1987, 26 (08): : L1260 - L1262
  • [6] Wavelength dispersive detector for synchrotron x-ray fluorescence microprobe analysis
    Rivers, Mark L.
    Sutton, Stephen R.
    Review of Scientific Instruments, 1995, 66 (2 pt 2):
  • [7] Synchrotron x-ray fluorescence microprobe quantitative analysis of heterogeneous samples
    Zavarin, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 81 - ENVR
  • [8] DEVELOPMENT OF A SCANNING-X-RAY MICROPROBE WITH SYNCHROTRON RADIATION
    HAYAKAWA, S
    IIDA, A
    AOKI, S
    GOHSHI, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2452 - 2455
  • [9] Synchrotron radiation based X-ray fluorescence analysis
    Sawhney, KJS
    X-RAY SPECTROSCOPY AND ALLIED AREAS, 1998, : 225 - 230
  • [10] FLUORESCENCE X-RAY ABSORPTION FINE-STRUCTURE MEASUREMENTS USING A SYNCHROTRON RADIATION X-RAY MICROPROBE
    HAYAKAWA, S
    GOHSHI, Y
    IIDA, A
    AOKI, S
    SATO, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (11): : 2545 - 2549