Design of Concrete Filled Tubular Beam-columns with High Strength Steel and Concrete

被引:198
|
作者
Liew, J. Y. Richard [1 ]
Xiong, Mingxiang [1 ]
Xiong, Dexin [1 ]
机构
[1] Natl Univ Singapore, Dept Civil & Environm Engn, Singapore, Singapore
关键词
Concrete filled columns; Eurocode steel design; High strength concrete; High rise buildings; High tensile steel; Steel-concrete composite; SECTION STUB COLUMNS; EXPERIMENTAL BEHAVIOR; BOX COLUMNS; CAPACITY; TESTS;
D O I
10.1016/j.istruc.2016.05.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete filled steel tubular columncomprising a hollowsteel tube infilled with concrete has been usedwidely in high rise buildings. Although modern design codes provide guides on concrete filled steel tubular members, they do not cover their applications involving high strength concrete and high tensile steel. Set against this background, new tests have been conducted to supplement the dearth of research on concrete filled steel tubular memberswith ultra-high strength concrete (f(ck) up to 190 N/mm(2)) and high tensile steel (f(y) up to 780 N/mm(2)). In this paper, a design guide has been proposed for concrete filled steel tubular members based on an extension of Eurocode 4method for concrete compressive strength up to 190 N/mm(2) and high tensile steelwith yield strength up to 550 N/mm2. More than 2030 test data collected from the literature on concrete filled steel tubes with normal and high strength materials have been analysed to formulate this design guide. This paper provides insights to this design guide sharing someof the expertise and knowledge involving the applications of high strength concrete filled tubular members in high rise buildings. (C) 2016 Institution of Structural Engineers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:213 / 226
页数:14
相关论文
共 50 条
  • [1] Flexural capacities of concrete filled square steel tubular beam-columns with high strength concrete
    Sakino, K
    Nakahara, H
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 473 - 480
  • [2] Strength and ductility of high strength concrete-filled steel tubular beam-columns
    Ling, Qing Quan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (03) : 687 - 698
  • [3] Simplified strength formula of concrete filled steel tubular beam-columns
    Chung, JN
    Matsui, C
    Tsuda, K
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 465 - 471
  • [4] Rectangular concrete-filled steel tubular beam-columns using high-strength steel: Experiments and design
    Du, Yansheng
    Chen, Zhihua
    Liew, J. Y. Richard
    Xiong, Ming-Xiang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 131 : 1 - 18
  • [5] Strength of rectangular concrete-filled tubular beam-columns
    Liu Dalin
    Gho Wie-Min
    8TH INTERNATIONAL CONFERENCE ON STEEL-CONCRETE COMPOSITE AND HYBRID STRUCTURES, PROCEEDINGS, 2006, : 91 - 97
  • [6] Fire performance of concrete filled steel tubular beam-columns
    Han, LH
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (06) : 695 - 709
  • [7] Simplified design formula of slender concrete filled steel tubular beam-columns
    Tsuda, K
    Matsui, C
    Chung, JN
    Fujinaga, T
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 457 - 464
  • [8] Simplified design formula of slender concrete filled steel tubular beam-columns
    Chung, J
    Matsui, C
    Tsuda, K
    STRUCTURAL ENGINEERING AND MECHANICS, 2001, 12 (01) : 71 - 84
  • [9] Nonlinear analysis of circular high strength concrete-filled stainless steel tubular slender beam-columns
    Patel, Vipulkumar Ishvarbhai
    Liang, Qing Quan
    Hadi, Muhammad N. S.
    ENGINEERING STRUCTURES, 2017, 130 : 1 - 13
  • [10] Numerical analysis of concrete filled tubular beam-columns
    Department of Civil Engineering, Escola de Minas, UFOP, Ouro Preto-MG, Brazil
    Weld. World, 2006, SPEC. ISS. (351-358):