Role of beat noise in limiting the sensitivity of optical coherence tomography

被引:10
|
作者
Haskell, Richard C. [1 ]
Liao, David [1 ]
Pivonka, Adam E. [1 ]
Bell, Tera L. [1 ]
Haberle, Brendan R. [1 ]
Hoeling, Barbara M. [1 ]
Petersen, Daniel C. [1 ]
机构
[1] Harvey Mudd Coll, Dept Phys, Claremont, CA 91711 USA
关键词
D O I
10.1364/JOSAA.23.002747
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The sensitivity and dynamic range of optical coherence tomography (OCT) are calculated for instruments utilizing two common interferometer configurations and detection schemes. Previous researchers recognized that the performance of dual-balanced OCT instruments is severely limited by beat noise, which is generated by incoherent light backscattered from the sample. However, beat noise has been ignored in previous calculations of Michelson OCT performance. Our measurements of instrument noise confirm the presence of beat noise even in a simple Michelson interferometer configuration with a single photodetector. Including this noise, we calculate the dynamic range as a function of OCT light source power, and find that instruments employing balanced interferometers and balanced detectors can achieve a sensitivity up to six times greater than those based on a simple Michelson interferometer, thereby boosting image acquisition speed by the same factor for equal image quality. However, this advantage of balanced systems is degraded for source powers greater than a few milliwatts. We trace the concept of beat noise back to an earlier paper.
引用
收藏
页码:2747 / 2755
页数:9
相关论文
共 50 条
  • [1] Noise and sensitivity in optical coherence tomography based vibrometry
    Kim, Sangmin
    Oghalai, John S.
    Applegate, Brian E.
    OPTICS EXPRESS, 2019, 27 (23) : 33332 - 33349
  • [2] Speckle noise reduction for optical coherence tomography
    Xiang, SH
    Zhou, L
    Schmitt, JM
    OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING III, PROCEEDINGS OF, 1998, 3196 : 79 - 88
  • [3] Sensitivity estimation of spectroscopic optical coherence tomography
    Hermann, B
    Sattmann, H
    Bizheva, K
    Povazay, B
    Unterhuber, A
    Leitgeb, R
    Schmetterer, L
    Krausz, F
    Fercher, AF
    Drexler, W
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS VI, 2002, 4619 : 145 - 148
  • [4] Measurement of ciliary beat frequency using Doppler optical coherence tomography
    Lemieux, Bryan T.
    Chen, Jason J.
    Jing, Joseph
    Chen, Zhongping
    Wong, Brian J. F.
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2015, 5 (11) : 1048 - 1054
  • [5] The Role of Optical Coherence Tomography and Optical Coherence Tomography Angiography in the Differential Diagnosis of Posterior Uveitis
    Agarwal, Aniruddha
    Invernizzi, Alessandro
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2022, 30 (03) : 682 - 689
  • [6] Efficient reduction of speckle noise in Optical Coherence Tomography
    Szkulmowski, Maciej
    Gorczynska, Iwona
    Szlag, Daniel
    Sylwestrzak, Marcin
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    OPTICS EXPRESS, 2012, 20 (02): : 1337 - 1359
  • [7] Phase noise and phase modulation in optical coherence tomography
    Parrein, P
    Meier, J
    APPLIED OPTICS, 2004, 43 (15) : 3010 - 3017
  • [8] Analyses and calculations of noise in optical coherence tomography systems
    Zhu X.
    Liang Y.
    Mao Y.
    Jia Y.
    Liu Y.
    Mu G.
    Frontiers of Optoelectronics in China, 2008, 1 (3-4): : 247 - 257
  • [9] Methods to assess sensitivity of optical coherence tomography systems
    Agrawal, Anant
    Pfefer, T. Joshua
    Woolliams, Peter D.
    Tomlins, Peter H.
    Nehmetallah, George
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (02): : 902 - 917
  • [10] Role of optical coherence tomography in unilateral amblyopia
    Ammari, W.
    Bayoudh, K.
    Khairallah, M.
    Zaghdoudi, A.
    Hbaieb, O.
    Mahmoud, A.
    Mbarek, S.
    Messaoud, R.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (04): : 348 - 355