Ion chromatographic determination of metals in biocompatibility testing

被引:0
|
作者
Buldini, PL
Mevoli, A
Sharma, JL
机构
[1] CNR Lamel, I-40129 Bologna, Italy
[2] Pastis SCpA, I-72100 Brindisi, Italy
[3] Univ Delhi, KM Coll, Delhi 110007, India
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2000年 / 50卷 / 02期
关键词
biocompatibility testing; implants; ion chromatography; metals release; UV photolysis;
D O I
10.1002/(SICI)1097-4636(200005)50:2<131::AID-JBM6>3.0.CO;2-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The increasing numbers of materials used in surgical implants require a wide spectrum of tests to evaluate their biocompatibility. The release of metals is an important additional feature for determining the suitability for clinical applications of biomaterials such as ceramics and metals. Due to the difficulty of performing time-consuming experiments in vivo, one approach for rapidly determining the suitability of biomaterials and their interactions with the tissues with which they will come in contact is to perform in vitro tests, based on cell culture analysis, using solutions that reproduce the cleavage and binding capabilities of body fluids and tissues. The present work reports on the application of ion chromatography to the simultaneous determination of some metal ions in a few biologic media. Agar-Agar solution, "199 medium," and betadine and Schiff's reagents were selected as some of the most representative biologic simulating solutions. A method is recommended for the pretreatment of the sample with minimal reagent addition since it is very rich in organic compounds and cannot be analyzed without pretreatment. The proposed procedure requires the sample to be subjected to oxidative UV photolysis for about 60 min in an UV digester at 85 degrees +/- 5 degrees C, followed by the ion chromatographic determination. Lead (II), cadmium (II), iron (III), copper (II), nickel (II), zinc (II), and cobalt (II) simultaneously were determined at mu g/L levels. (C) 2000 John Wiley & Sons, Inc.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 50 条
  • [1] ION CHROMATOGRAPHIC DETERMINATION OF TOTAL METALS IN SOILS
    BASTA, NT
    TABATABAI, MA
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1990, 54 (05) : 1289 - 1297
  • [3] Ion Chromatographic Method for Determination of Heavy Metals in Water
    Bajenaru , Irina
    Josceanu, Ana Maria
    Guran, Cornelia
    Minca, Iulian
    REVISTA DE CHIMIE, 2015, 66 (12): : 1960 - 1964
  • [4] Ion-chromatographic determination of transition metals in soils
    Obrezkov, ON
    Semenova, SN
    Zhukov, SR
    Shpigun, OA
    INDUSTRIAL LABORATORY, 1996, 62 (12): : 750 - 754
  • [5] ION-PAIR CHROMATOGRAPHIC DETERMINATION OF METALS IN CYANIDE ELECTROLYTES
    PADARAUSKAS, AV
    KAZLAUSKAS, RM
    PETRUKHIN, OM
    INDUSTRIAL LABORATORY, 1991, 57 (11): : 1110 - 1112
  • [6] THE ION CHROMATOGRAPHIC DETERMINATION OF ALKALI-METALS IN PROPANOL SOLUTIONS
    JOHNSON, K
    TARTER, JG
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1989, 7 (03): : 266 - 267
  • [7] Ion chromatographic and voltammetric determination of heavy and transition metals in honey
    Buldini, PL
    Cavalli, S
    Mevoli, A
    Sharma, JL
    FOOD CHEMISTRY, 2001, 73 (04) : 487 - 495
  • [8] ION CHROMATOGRAPHIC DETERMINATION OF SOME METALS AS ANION COMPLEX WITH EDTA
    OBREZKOV, ON
    SHLYAMIN, VI
    SHPIGUN, OA
    ZOLOTOV, YA
    ANALYTICAL SCIENCES, 1991, 7 (02) : 321 - 325
  • [9] ION CHROMATOGRAPHIC DETERMINATION OF SOME METALS AS ANION COMPLEXES WITH EDTA
    OBREZKOV, ON
    SLYAMIN, VI
    SHPIGUN, OA
    ANALYTICAL SCIENCES, 1990, 6 (04) : 617 - 618
  • [10] VALIDATION OF AN ION CHROMATOGRAPHIC METHOD FOR DETERMINATION OF HEAVY METALS IN WATER
    Bajenaru , Irina Gentiana
    Guran, Cornelia
    Josceanu, Ana Maria
    Minca, Iulian
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2015, 77 (01): : 129 - 140