Multicommutated flow analysis system for determination of total protein in cerebrospinal fluid

被引:8
|
作者
Strzelak, Kamil [1 ,2 ]
Wisniewska, Agnieszka [3 ]
Bobilewicz, Dagna [3 ]
Koncki, Robert [1 ]
机构
[1] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
[2] Univ Warsaw, MISMaP Coll, PL-02093 Warsaw, Poland
[3] Med Univ Warsaw, Fac Hlth Sci, Dept Lab Diagnost, PL-02097 Warsaw, Poland
关键词
Cerebrospinal fluid; Protein determination; Multicommutation; Optoelectronic detector; EMITTER-DETECTOR-DIODES; CSF TOTAL PROTEIN; URINARY PROTEIN; TURBIDIMETRY; DISORDERS; SENSOR;
D O I
10.1016/j.talanta.2014.04.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully mechanized, computer-controlled, multicommutated flow analysis (MCFA) system dedicated for total protein determination in cerebrospinal fluid samples has been developed. For the protein determination the Exton method has been applied. Dedicated turbidimetric and nephelometric flow-through detectors operating according to paired-emitter detector diode principle have been fabricated by integration of two or three respective light emitting diodes. The developed MCFA system is characterized by robust, compact design and low consumption of the sample (72 mu L). The limits of detection for turbidimetric and nephelometric detection mode are 65 mg L-1 and 9 mg L-1, respectively. For turbidimetric measurements the range of linear response offered by the MCFA system is 72-900 mg L-1, whereas in the case of nephelometric detection 18-500 mg L-1 linear range is obtained. The throughput of the MCFA system is over 30 injection per hour. The analytical system was optimized with bovine serum albumin standards and successfully validated with real samples of human cerebrospinal fluid. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [1] The determination of total protein, sugar and chlorides in cerebrospinal fluid
    Bernhard, A
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1938, 23 : 179 - 180
  • [2] SPECTROPHOTOMETRIC DETERMINATION OF TOTAL PROTEIN IN CEREBROSPINAL-FLUID
    KOBAYASHI, T
    FOLIA PSYCHIATRICA ET NEUROLOGICA JAPONICA, 1959, 13 (02): : 184 - 184
  • [3] A MULTICOMMUTATED FLOW SYSTEM FOR PERACETIC ACID DETERMINATION
    Campos Barbosa da Silva, Fabiola Soraia Vital
    da Silva Junior, Joilton Jose
    Lavorante, Andre Fernando
    Silveira Paim, Ana Paula
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 1 (03): : 158 - 163
  • [4] A MICRO BIURET METHOD FOR PROTEIN DETERMINATION - DETERMINATION OF TOTAL PROTEIN IN CEREBROSPINAL FLUID
    GOA, J
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1953, 5 (03): : 218 - 222
  • [5] Multicommutated Flow Analysis System for Determination of Horseradish Peroxidase and Its Inhibitors
    Glowacka, Justyna
    Strzelak, Kamil
    Koncki, Robert
    MOLECULES, 2021, 26 (18):
  • [6] On-line 'protein shaker': A multicommutated flow analysis system for fluorometric creatinine determination in deproteinized serum
    Malicka, Iga
    Lewinska, Izabela
    Tymecki, Lukasz
    ANALYTICA CHIMICA ACTA, 2022, 1191
  • [7] Multicommutated flow analysis system for determination of creatinine in physiological fluids by Jaffe method
    Tymecki, Lukasz
    Korszun, Jakub
    Strzelak, Kamil
    Koncki, Robert
    ANALYTICA CHIMICA ACTA, 2013, 787 : 118 - 125
  • [8] Automated spectrophotometric determination of clomipramine on a multicommutated flow system
    Lima, JLFC
    Prior, JAV
    Reis, BF
    Santos, JLM
    Zagatto, EAG
    ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) : 75 - 81
  • [9] Chemiluminometric determination of propranolol in an automated multicommutated flow system
    Marques, KL
    Santos, JLM
    Lima, JLFC
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (05) : 886 - 891
  • [10] Biparametric multicommutated flow analysis system for determination of human serum phosphoesterase activity
    Tymecki, Lukasz
    Strzelak, Kamil
    Koncki, Robert
    ANALYTICA CHIMICA ACTA, 2013, 797 : 57 - 63