Similarity of chest X-ray and thermal imaging of focal pneumonia: a randomised proof of concept study at a large urban teaching hospital

被引:4
|
作者
Wang, Linda T. [1 ,2 ]
Cleveland, Robert H. [3 ,4 ]
Binder, William [5 ]
Zwerdling, Robert G. [6 ]
Stamoulis, Caterina [7 ,8 ]
Ptak, Thomas [7 ,8 ]
Sherman, Mindy [1 ,2 ]
Haver, Kenan [3 ]
Sagar, Pallavi [9 ]
Hibberd, Patricia [10 ]
机构
[1] Massachusetts Gen Hosp, Dept Emergency Med, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Pediat, Boston, MA 02114 USA
[3] Boston Childrens Hosp, Dept Radiol, Boston, MA 02115 USA
[4] Boston Childrens Hosp, Dept Med, Boston, MA 02115 USA
[5] Brown Univ, Alpert Sch Med, Dept Emergency Med, Providence, RI 02912 USA
[6] Univ Massachusetts, Med Ctr, Dept Pediat, Worcester, MA USA
[7] Univ Maryland, Med Ctr, Dept Radiol & Nucl Med, Baltimore, MD 21201 USA
[8] R Adams Cowley Shock Trauma Ctr, Baltimore, MD USA
[9] Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA
[10] Boston Univ, Dept Global Hlth, Boston, MA 02215 USA
来源
BMJ OPEN | 2018年 / 8卷 / 01期
关键词
COMMUNITY-ACQUIRED PNEUMONIA; DIAGNOSING PNEUMONIA; LUNG ULTRASOUND; COMPUTED-TOMOGRAPHY; ACUTE COUGH; CHILDREN; JUDGMENT; CARE;
D O I
10.1136/bmjopen-2017-017964
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To assess the diagnostic accuracy of thermal imaging (TI) in the setting of focal consolidative pneumonia with chest X-ray (CXR) as the gold standard. Setting A large, 973-bed teaching hospital in Boston, Massachusetts. Participants 47 patients enrolled, 15 in a training set, 32 in a test set. Age range 10 months to 82 years (median=50 years). Materials and methods Subjects received CXR with subsequent TI within 4 hours of each other. CXR and TI were assessed in blinded random order. Presence of focal opacity (pneumonia) on CXR, the outcome parameter, was recorded. For TI, presence of area(s) of increased heat (pneumonia) was recorded. Fisher's exact test was used to assess the significance of the correlations of positive findings in the same anatomical region. Results With TI compared with the CXR (the outcome parameter), sensitivity was 80.0% (95% Cls 29.9% to 98.9%), specificity was 57.7% (95% CI 37.2% to 76.00/0). Positive predictive value of TI was 26.7% (95% CI 8.9% to55.2%) and its negative predictive value was 93.8% (95% CI 67.7% to 99.7%). Conclusions This feasibility study confirms proof of concept that chest TI is consistent with CXR in suggesting similarly localised focal pneumonia with high sensitivity and negative predictive value. Further investigation of TI as a point-of-care imaging modality is warranted.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Texture Analysis in the Evaluation of COVID-19 Pneumonia in Chest X-Ray Images: A Proof of Concept Study
    Cavallo, Armando Ugo
    Troisi, Jacopo
    Forcina, Marco
    Mari, Pier-Valerio
    Forte, Valerio
    Sperandio, Massimiliano
    Pagano, Sergio
    Cavallo, Pierpaolo
    Floris, Roberto
    Garaci, Francesco
    CURRENT MEDICAL IMAGING, 2021, 17 (09) : 1094 - 1102
  • [2] Imaging - Chest X-ray for every Pneumonia: contra
    Hauenstein, Ch.
    ALLERGOLOGIE, 2019, 42 (05) : 222 - 222
  • [3] A STUDY ON PULMONARY INVOLVEMENT IN CHRONIC RHEUMATOID ARTHRITIS WITH CHEST X-RAY AND SPIROMETRY IN A TEACHING HOSPITAL
    Anand, Rajeev
    Jacobi, Baiju Sam
    Rao, Balachandran Jayachandra
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (04): : 495 - 498
  • [4] Chest X-Ray Imaging Severity Score of COVID-19 Pneumonia
    Garea-Llano, Eduardo
    Diaz-Berenguer, Abel
    Sahli, Hichem
    Gonzalez-Dalmau, Evelio
    PATTERN RECOGNITION, MCPR 2023, 2023, 13902 : 211 - 220
  • [5] Proof of Concept for X-Ray Backscatter Imaging Tomosynthesis Using Spectral Detection
    Rolison, Lucas M.
    Samant, Sanjiv S.
    Jordan, Kelly A.
    Baciak, James E.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [6] Technical Note: Nuclear imaging with an x-ray flat panel detector: A proof-of-concept study
    Dietze, Martijn M. A.
    Koppert, Wilco J. C.
    van Rooij, Rob
    de Jong, Hugo W. A. M.
    MEDICAL PHYSICS, 2020, 47 (08) : 3363 - 3368
  • [7] Dark-field chest X-ray imaging for the assessment of COVID-19-pneumonia
    Manuela Frank
    Florian T. Gassert
    Theresa Urban
    Konstantin Willer
    Wolfgang Noichl
    Rafael Schick
    Manuel Schultheiss
    Manuel Viermetz
    Bernhard Gleich
    Fabio De Marco
    Julia Herzen
    Thomas Koehler
    Klaus Jürgen Engel
    Bernhard Renger
    Felix G. Gassert
    Andreas Sauter
    Alexander A. Fingerle
    Bernhard Haller
    Marcus R. Makowski
    Daniela Pfeiffer
    Franz Pfeiffer
    Communications Medicine, 2
  • [8] Dark-field chest X-ray imaging for the assessment of COVID-19-pneumonia
    Frank, Manuela
    Gassert, Florian T.
    Urban, Theresa
    Willer, Konstantin
    Noichl, Wolfgang
    Schick, Rafael
    Schultheiss, Manuel
    Viermetz, Manuel
    Gleich, Bernhard
    De Marco, Fabio
    Herzen, Julia
    Koehler, Thomas
    Engel, Klaus Juergen
    Renger, Bernhard
    Gassert, Felix G.
    Sauter, Andreas
    Fingerle, Alexander A.
    Haller, Bernhard
    Makowski, Marcus R.
    Pfeiffer, Daniela
    Pfeiffer, Franz
    COMMUNICATIONS MEDICINE, 2022, 2 (01):
  • [9] Can portable tomosynthesis improve the diagnostic value of bedside chest X-ray in the intensive care unit? A proof of concept study
    Cant J.
    Snoeckx A.
    Behiels G.
    Parizel P.M.
    Sijbers J.
    European Radiology Experimental, 1 (1)
  • [10] Fluorescent X-Ray Computed Tomography towards Molecular Imaging: Proof-of-Concept Experiments
    Yuasa, Tetsuya
    Huo, Qingkai
    Akatsuka, Takao
    Takeda, Tohoru
    Hyodo, Kazuyuki
    Dilmanian, F. Avraham
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 874 - 877