Compressive test of GFRP-recycled aggregate concrete-steel tubular long columns

被引:33
|
作者
Zeng, Lan [1 ,2 ]
Li, Lijuan [1 ]
Su, Zhi [3 ]
Liu, Feng [1 ]
机构
[1] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Univ Wollongong, Fac Engn & Informat Sci, Wollongong, NSW 2500, Australia
[3] Keyland, Hangzhou 310003, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Glass fibre-reinforced polymer (GFRP); Double-skin tubular column (DSTC); Recycled aggregate concrete (RAC); Long column; Axial compression; Ultimate bearing capacity; FRP-CONFINED CONCRETE; AXIAL-COMPRESSION; MECHANICAL-BEHAVIOR; COMPOSITE COLUMNS; BRIDGES; DESIGN; TUBE; PERFORMANCE; CAPACITY; MODEL;
D O I
10.1016/j.conbuildmat.2018.05.068
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to alleviate the problem of growing construction waste and utilize the favorable material properties of fibre-reinforced polymer (FRP), a novel form of composites, FRP-recycled aggregate concrete steel columns (FRSCs), was proposed based on hybrid FRP-concrete-steel double-skin tubular columns (DSTCs). The composite of FRSC consists an outer FRP tube and an inner steel tube with an annular area of recycled aggregate concrete (RAC) filled between both tubes. To further investigate the compressive behavior of these composites, an experiment of Glass FRP-RAC-steel tubular long columns (FRSLCs) was performed subjected to monotonic axial compression. Three parameters were designed in the test, which are the recycled coarse aggregate (RCA) replacement ratio, the slenderness ratio and the cross-section loading method. The influence of these parameters was analyzed on the bearing capacity, lateral deflection performance and the load-strain relationship of FRSLCs. The test results show that FRSLCs have good bearing capacity and excellent ductility. Two models for DSTCs were transformed to apply in FRSLCs, which has found that Lu's model (2013) is appropriate to predict the ultimate bearing capacity of FRSLCs under the whole area loading. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:295 / 312
页数:18
相关论文
共 50 条
  • [2] Mechanical behavior of GFRP-recycled concrete-steel multitube concrete columns under axial compression
    Zhang, Fubin
    Hu, Zheng
    Xiao, Jianzhuang
    Xie, Shaofeng
    Zhang, Bing
    Fang, Hai
    JOURNAL OF BUILDING ENGINEERING, 2023, 77
  • [3] Study of compressive behaviour of FRP-recycled aggregate concrete-steel stub columns
    Zeng, Lan
    Li, Lijuan
    Chen, Liang
    Liu, Feng
    MAGAZINE OF CONCRETE RESEARCH, 2019, 71 (15) : 794 - 808
  • [4] Axial compressive behavior of GFRP tube-reinforced concrete-steel double skin tubular columns
    Gao, Haiyang
    Wang, Lianguang
    Chen, Bailing
    Yan, Meng
    JOURNAL OF BUILDING ENGINEERING, 2023, 75
  • [5] Compression behavior of GFRP-coal gangue concrete-steel tubular columns
    Zhang, Ni
    Zhao, Zhongwei
    Zheng, Chenyang
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2022, 197
  • [6] Compressive Behavior of Rectangular Recycled Aggregate Concrete-Filled Steel-Tubular Stub Columns
    Yang Y.-F.
    Huang X.-Y.
    1600, South China University of Technology (45): : 121 - 127
  • [7] Axial compressive behavior of recycled ceramic coarse aggregate concrete-filled steel tubular columns
    Wang, Yi
    Huang, Hong
    Zeng, Jiantao
    Hu, Wenbin
    Cheng, Yingyao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 210
  • [8] Experimental Behavior of Recycled Aggregate Concrete Filled Steel Tubular Columns
    R. Thirumalai
    A. R. Krishnaraja
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2023, 38 : 1414 - 1417
  • [9] Experimental behaviour of recycled aggregate concrete filled steel tubular columns
    Yang, You-Fu
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (12) : 1310 - 1324
  • [10] Axial compressive performance of concrete-filled double skin steel tubular columns using recycled aggregate concrete
    Tian, Hui-Wen
    Li, Wei
    Lai, Long-Hai
    ENGINEERING STRUCTURES, 2025, 328