Vectorcardiogram synthesized from the 12-lead electrocardiogram to image ischemia

被引:24
|
作者
Strauss, David G. [1 ,2 ,3 ]
Olson, Charles W. [4 ]
Wu, Katherine C. [2 ]
Heiberg, Einar [1 ]
Persson, Eva [1 ]
Selvester, Ronald H. [5 ]
Pahlm, Olle [1 ]
Arheden, Hakan [1 ]
机构
[1] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[2] Johns Hopkins Univ, Dept Med, Div Cardiol, Baltimore, MD USA
[3] Duke Univ, Sch Med, Durham, NC USA
[4] ECG TECH Corp, Huntington Stn, NY USA
[5] Mem Hosp, Res Ctr, Long Beach, CA USA
关键词
Electrocardiography; Imaging; Ischemia; Scintigraphy; ACUTE MYOCARDIAL-INFARCTION; ST-SEGMENT DEVIATION; LONG-AXIS ORIENTATION; CORONARY ANGIOPLASTY; RISK; SIZE; CARDIOLOGIST; REPERFUSION; HEART;
D O I
10.1016/j.jelectrocard.2008.12.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Knowledge of the location and size of ischemic myocardium at risk for infarction Could impact prehospital patient triage and reperfusion therapy. The 12-lead electrocardiogram (ECG) can roughly estimate ischemia size; however, individual precordial ECG leads are at different distances from the left ventricle (LV) and certain LV walls have greater effects on the ECG. Vectorcardiographic corrected orthogonal lead systems can display the magnitude and direction of the ST-segment "injury current" vector in 3-dimensional space. We assessed whether the vectorcardiographic ST-vector direction and magnitude derived from the ECG by the inverse-Dower method can estimate the location and size of ischemia. Methods and Results: Thirty-two patients underwent elective coronary angioplasty with control and 5-minute balloon-occlusion ECG and sestamibi injection followed by single photon emission computed tomography (SPECT). The ST-vector direction derived from the inverse-Dower method was projected to an LV model with normal coronary artery anatomy. The graphical display of ST-vector location Could discriminate among occlusions of the different coronaries. The ST-vector located ischemia within the SPECT defect in 75% (24/32) of all patients and 96% (24/25) of patients with ischemia in more than 12% of the LV. ST-vector magnitude had a Spearman correlation of r = 0.68 (P < .0001) with SPECT ischemia size. Conclusions: The 3-dimensional ST vector derived from the ECG can be graphically projected onto an LV model to localize ischemia, and ST-vector magnitude correlates with ischemia size. Further study is warranted to assess the ability of vectorcardiographic imaging to risk-stratify and provide decision-support for patients with acute myocardial infarction. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 50 条
  • [1] Derivation of the 12-lead electrocardiogram and 3-lead vectorcardiogram
    Schreck, David M.
    Fishberg, Robert D.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (08): : 1183 - 1190
  • [2] VECTORCARDIOGRAM SYNTHESIZED FROM A 12-LEAD ECG - SUPERIORITY OF THE INVERSE DOWER MATRIX
    EDENBRANDT, L
    PAHLM, O
    JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 (04) : 361 - 367
  • [3] Detection of acute ischemia from the EASI-derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice
    Sejersten, Maria
    Wagner, Galen S.
    Pahlm, Olle
    Warren, James W.
    Feldman, Charles L.
    Horacek, B. Milan
    JOURNAL OF ELECTROCARDIOLOGY, 2007, 40 (02) : 120 - 126
  • [4] Transformation of the Mason-Likar 12-Lead Electrocardiogram to the Frank Vectorcardiogram
    Guldenring, Daniel
    Finlay, Dewar D.
    Strauss, David G.
    Galeotti, Loriano
    Nugent, Chris D.
    Donnelly, Mark P.
    Bond, Raymond R.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 677 - 680
  • [5] Is the EASI 12-lead electrocardiogram comparable to the standard 12-lead electrocardiogram for diagnosing cardiac rhythm and myocardial ischemia?
    Drew, BJ
    Pelter, MM
    Adams, MG
    Wung, SF
    Taylor, CA
    Banks, AS
    CIRCULATION, 1999, 100 (18) : 736 - 736
  • [6] ENHANCEMENT OF DIAGNOSTIC PERFORMANCE OF THE 12-LEAD ECG BY USING MEASUREMENTS FROM THE SYNTHESIZED VECTORCARDIOGRAM
    PETTERSSON, J
    EDENBRANDT, L
    PAHLM, O
    HAISTY, WK
    JOURNAL OF ELECTROCARDIOLOGY, 1993, 26 : 95 - 95
  • [7] 12-LEAD ELECTROCARDIOGRAM
    REES, P
    BRITISH MEDICAL JOURNAL, 1968, 1 (5594): : 768 - &
  • [8] The spatial QRS-T angle in the Frank vectorcardiogram: accuracy of estimates derived from the 12-lead electrocardiogram
    Schreurs, Charlotte A.
    Algra, Annemijn M.
    Man, Sum-Che
    Cannegieter, Suzanne C.
    van der Wall, Ernst E.
    Schalij, Martin J.
    Kors, Jan A.
    Swenne, Cees A.
    JOURNAL OF ELECTROCARDIOLOGY, 2010, 43 (04) : 294 - 301
  • [9] Diagnostic conclusions from the EASI-derived 12-lead electrocardiogram as compared with the standard 12-lead electrocardiogram in children
    Welinder, A
    Feild, DQ
    Liebman, J
    Maynard, C
    Wagner, GS
    Wettrell, G
    Pahlm, O
    AMERICAN HEART JOURNAL, 2006, 151 (05) : 1059 - 1064
  • [10] Reconstruction of the 12-lead electrocardiogram from reduced lead sets
    Nelwan, SP
    Kors, JA
    Meij, SH
    van Bemmel, JH
    Simoons, ML
    JOURNAL OF ELECTROCARDIOLOGY, 2004, 37 (01) : 11 - 18