Polymeric absorbers for flat plate collectors: Can venting provide adequate overheat protection?

被引:0
|
作者
Kearney, Meghan [1 ]
Davidson, Jane H. [1 ]
Mantell, Susan [1 ]
机构
[1] Dept Mech Engn, Minneapolis, MN 55455 USA
来源
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Venting and evaporative cooling are modeled as possible techniques for protecting polymer absorbers in single-glazed, flat-plate solar collectors from exceeding the material temperature limit dining dry stagnation. Four venting options arc considered: I) venting above the absorber plate, II) venting below, III) dual venting, and IV) venting with evaporative cooling. Results indicate that in hot, sunny conditions, venting may not provide adequate cooling to lower the absorber temperature to the relative thermal index of the polymeric materials currently in use or under consideration for this application. Venting combined with evaporative cooling from a wetted pad directly beneath the absorber plate is identified as a potential method of overheat protection in hot, dry climates.
引用
收藏
页码:253 / 257
页数:5
相关论文
共 7 条
  • [1] Polymeric absorbers for flat-plate collectors: Can venting provide adequate overheat protection?
    Kearney, M
    Davidson, J
    Mantell, S
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 421 - 424
  • [2] FREEZE PROTECTION FOR FLAT-PLATE COLLECTORS USING HEATING
    WILCOX, BA
    BARNABY, CS
    SOLAR ENERGY, 1977, 19 (06) : 745 - 746
  • [3] Thermotropic layers for flat-plate collectors-A review of various concepts for overheating protection with polymeric materials
    Resch, Katharina
    Wallner, Gernot M.
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2009, 93 (01) : 119 - 128
  • [4] Thermal performance of flat plate solar collectors with sheet-and-tube and roll-bond absorbers
    Del Col, Davide
    Padovan, Andrea
    Bortolato, Matte
    Pre, Marco Dai
    Zambolin, Enrico
    ENERGY, 2013, 58 : 258 - 269
  • [5] Can retrograde cardioplegia alone provide adequate protection for cardiac valve surgery?
    Talwalkar, NG
    Lawrie, GM
    Earle, N
    DeBakey, ME
    CHEST, 1999, 115 (01) : 135 - 139
  • [6] First test field performance of highly efficient flat plate solar collectors with transparent insulation and low-cost overheating protection
    Kizildag, D.
    Castro, J.
    Kessentini, H.
    Schillaci, E.
    Rigola, J.
    SOLAR ENERGY, 2022, 236 : 239 - 248
  • [7] Daily Variations of Water Temperature and Useful Heat Accumulation in Flat-Plate Solar Water-Heating Collectors with Capacitive Solar Radiation Absorbers with Bottom Absorption of Radiation
    Avezov R.R.
    Kasimov F.S.
    Niyazov S.K.
    Kasimov, F. Sh. (fahri2002@mail.ru), 1600, Pleiades journals (56): : 242 - 247