Orchiopexy using 2 mm. laparoscopic instruments: 2 Techniques for delivering the testis into the scrotum

被引:2
|
作者
Ferrer, FA [1 ]
Cadeddu, JA
Schulam, P
Mathews, R
Docimo, SG
机构
[1] Johns Hopkins Univ, Sch Med, James Buchanan Brady Urol Inst, Baltimore, MD 21205 USA
[2] Baylor Coll Med, Dept Urol, Houston, TX 77030 USA
[3] Syracuse Univ, Div Urol, Syracuse, NY USA
来源
JOURNAL OF UROLOGY | 2000年 / 164卷 / 01期
关键词
testis; laparoscopy; cryptorchidism;
D O I
10.1016/S0022-5347(05)67486-1
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We describe modified techniques of laparoscopic orchiopexy using 2 mm. instruments that enable straightforward delivery of the testis into the scrotum. Materials and Methods: The preferred technique involves a radially dilating trocar advanced over the 2 mm. grasper placed antegrade through the new internal ring. The other method is similar but Amplatz dilators are used when a radially dilating trocar system is not available. Results: We used these techniques with complete success to deliver 18 testes into the scrotum. Conclusions: The testis may be safely and effectively delivered to the scrotum using 2 mm. instruments and disposable fascial dilators or a radially dilating trocar system.
引用
收藏
页码:160 / 161
页数:2
相关论文
共 50 条
  • [1] Laparoscopic cholecystectomy using 2-mm instruments
    Uranus, S
    Peng, ZH
    Kronberger, L
    Pfeifer, J
    Salehi, B
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A, 1998, 8 (05): : 255 - 259
  • [2] Pediatric retroperitoneoscopic nephrectomy using 2 mm. instrumentation
    Borer, JG
    Cisek, LJ
    Atala, A
    Diamond, DA
    Retik, AB
    Peters, CA
    JOURNAL OF UROLOGY, 1999, 162 (05): : 1725 - 1729
  • [3] A comparative study between two techniques of laparoscopic orchiopexy for intra-abdominal testis
    Bawazir, Osama Abdullah
    Maghrabi, Abdulrahman M.
    INDIAN JOURNAL OF UROLOGY, 2021, 37 (03) : 261 - 266
  • [4] Laparoscopic Ist stage orchiopexy using antiadherent sheet for high abdominal testis
    Falchetti, D.
    Corasaniti, L.
    Lanata, M.
    Argento, S.
    Pellegrino, M.
    Dessanti, A.
    JOURNAL OF PEDIATRIC SURGERY CASE REPORTS, 2020, 60
  • [5] EXPERIENCE WITH 2-STAGE ORCHIOPEXY FOR UNDESCENDED TESTIS
    LIVNE, PM
    SAVIR, A
    JOURNAL OF UROLOGY, 1986, 135 (04): : A332 - A332
  • [6] Needlescopic urology: Incorporating 2-mm instruments in laparoscopic surgery
    Soble, JJ
    Gill, IS
    UROLOGY, 1998, 52 (02) : 187 - 194
  • [7] Gasless laparoscopic cholecystectomy with mini-instruments (2 mm) video
    Queiroz-Medeiros, MJ
    Menezes-Silva, A
    d'Almeida, JRR
    Dias, HV
    Nunes, JL
    Balhana, C
    BRITISH JOURNAL OF SURGERY, 1998, 85 : 204 - 204
  • [8] FREQUENCY CONVERTER AT WAVELENGTH OF 2. 5 mm.
    Bordonskiy, G.S.
    Strukov, I.A.
    Khapin, Yu.B.
    Etkin, V.S.
    Radio Engineering and Electronic Physics (English translation of Radiotekhnika i Elektronika), 1976, 21 (03): : 88 - 93
  • [9] Needlescopic urology: Incorporating 2-mm instruments in laparoscopic surgery - Comment
    Docimo, SG
    UROLOGY, 1998, 52 (02) : 194 - 194
  • [10] Laparoendoscopic Single-Site Pyeloplasty Using Additional 2 mm Instruments: A Comparison with Conventional Laparoscopic Pyeloplasty
    Ju, Sung Ho
    Lee, Dong-Gi
    Lee, Jun Ho
    Baek, Min Ki
    Jeong, Byong Chang
    Jeon, Seong Soo
    Lee, Kyu-Sung
    Han, Deok Hyun
    KOREAN JOURNAL OF UROLOGY, 2011, 52 (09) : 616 - 621