Study on a Field Data of Secondary Arc Extinction Time for Large-sized Transmission Lines

被引:36
|
作者
Tsuboi, Toshihiro [1 ]
Takami, Jun [1 ]
Okabe, Shigemitsu [1 ]
Aoki, Kojiro [1 ]
Yamagata, Yoshibumi [1 ]
机构
[1] Tokyo Elect Power Co Ltd, High Voltage & Insulat Grp, R&D Ctr, Tsurumi Ku, Yokohama, Kanagawa 2308510, Japan
关键词
Lightning fault; primary fault current; reclosing time; recovery voltage; secondary arc current; secondary arc extinction time;
D O I
10.1109/TDEI.2013.6678880
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Secondary arc extinction time is an important factor, which influences system stability because it directly affects the reclosing time. However, few reports exist on a field data of the secondary arc extinction time on transmission lines. This paper describes the investigation results of secondary arc extinction characteristics by analyzing voltage wave shapes during the lightning faults on 550 kV transmission lines. Recovery voltages and secondary arc currents on each transmission line during faults were calculated to consider correlation with the secondary arc extinction time. The secondary arc extinction time is estimated by the existing formula, the secondary arc current and the recovery voltage required for one second reclosing are evaluated.
引用
收藏
页码:2277 / 2286
页数:10
相关论文
共 50 条
  • [1] Analysis of Aspects of Lightning Strokes to Large-sized Transmission Lines
    Okabe, Shigemitsu
    Tsuboi, Toshihiro
    Takami, Jun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (01) : 182 - 191
  • [2] Comparison of secondary arc extinction methods for UHV transmission lines
    Sun, Qiuqin
    Li, Qingquan
    Li, Qingmin
    Wang, Guan
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2009, 29 (04): : 76 - 80
  • [3] The Analysis of Secondary Arc Extinction Characteristics on UHV Transmission Lines
    He Baina
    Lin Xin
    Xu Jianyuan
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 516 - 519
  • [4] Method of Calculating the Lightning Outage Rate of Large-sized Transmission Lines
    Taniguchi, Sakae
    Tsuboi, Toshihiro
    Okabe, Shigemitsu
    Nagaraki, Yoshimi
    Takami, Jun
    Ota, Hiroshi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (04) : 1276 - 1283
  • [5] Simulation for self-extinction behavior of secondary arc in transmission lines
    Yan, X. (yanxl@epri.sgcc.com.cn), 1600, Science Press (38):
  • [6] Development of large-sized Li secondary batteries
    Horiba, T
    Ishizu, T
    Kojima, T
    Takahashi, K
    Koseki, M
    Muranaka, Y
    INTELEC'03: POWERING THE BROADBAND NETWORK, PROCEEDINGS, 2003, : 230 - 233
  • [7] Development of large-sized Li secondary batteries
    Horiba, T
    Ishizu, T
    Kojima, T
    Takahashi, K
    Koseki, M
    Muranaka, Y
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2004, E87B (12) : 3485 - 3489
  • [8] Impacting factors of large-sized model test for lightning shielding performance of UHV transmission lines
    An, Y. (anyunzhu2006@163.com), 1600, Power System Technology Press (38):
  • [9] Study on the temperature field of large-sized sapphire single crystal furnace
    Zhai, J. P.
    Jiang, J. W.
    Liu, K. G.
    Peng, X. B.
    Jian, D. L.
    Li, I. L.
    2ND INTERNATIONAL CONFERENCE ON NEW MATERIAL AND CHEMICAL INDUSTRY (NMCI2017), 2018, 292
  • [10] A Study on the Transient of Secondary Arc Current of UHV Transmission Lines
    Sun, Qiuqin
    Xiao, Zhibin
    Liu, Hongshun
    Li, Qingmin
    Wang, Feng
    IEEE ACCESS, 2018, 6 : 38616 - 38626