Evaluation of a wireless three dimensional MEMS accelerometer reflex quantification device using an artificial reflex system

被引:0
|
作者
LeMoyne, Robert [1 ]
Coroian, Cristian [2 ]
Mastroianni, Timothy [3 ]
机构
[1] Univ Calif Los Angeles, Biomed Engn IDP, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[3] Cognit Engn, Pittsburgh, PA USA
关键词
reflex; reflex loop; reflex response; reflex latency; wireless accelerometers; reflex quantification; PATELLAR TENDON REFLEXES; DEMYELINATING POLYNEUROPATHY; QUANTITATIVE-EVALUATION; STRETCH REFLEX; SPASTICITY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An essential aspect for the neurological examination is the assessment of the deep tendon reflex. The deep tendon reflex is commonly conducted by a clinician through evoking the patellar tendon reflex. The significant parameters are the reflex response and the latency of the reflex loop. The characteristics of the reflex response and latency are representative of the severity and status attributes for upper motor neuron syndrome and peripheral neuropathy. The qualitative assessment from a clinician can be quantified through an ordinal scale, for example the NINDS Myotatic Reflex Scale. The accuracy of the ordinal scales for reflex response quantification is a subject of controversy. Another issue is the ordinal scales do not include temporal characterization of the reflex response. Latency can be derived with electrodiagnostic examination. However, electrodiagnostic examinations inherently involve the use of specialized and expensive resources. An alternative system that integrates tandem operated wireless 3D MEMS accelerometers for the quantification of reflex response and latency has been developed. The reflex response is quantified through positioning a wireless 3D MEMS accelerometer on the lower leg. A tandem and synchronized wireless 3D MEMS accelerometer is mounted to the swing arm that provides a quantified input for evoking the reflex. Latency is derived from the temporal disparity of the synchronized acceleration waveforms from the tandem wireless 3D MEMS accelerometers. Given the inherent variability of the deep tendon reflex, a mechanical artificial reflex device has been developed to evaluate the reflex quantification system incorporating wireless 3D MEMS accelerometers. The test and evaluation of the wireless 3D MEMS accelerometer reflex quantification system demonstrates considerable precision and accuracy imperative for reproducibility.
引用
收藏
页码:485 / +
页数:2
相关论文
共 50 条
  • [1] WIRELESS THREE DIMENSIONAL ACCELEROMETER REFLEX QUANTIFICATION DEVICE WITH ARTIFICIAL REFLEX SYSTEM
    Lemoyne, Robert
    Mastroianni, Timothy
    Coroian, Cristian
    Grundfest, Warren
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2010, 10 (03) : 401 - 415
  • [2] Wireless accelerometer reflex quantification system characterizing response and latency
    LeMoyne, Robert
    Coroian, Cristian
    Mastroianni, Timothy
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5283 - +
  • [3] Implementation of an iPhone wireless accelerometer application for the quantification of reflex response
    LeMoyne, Robert
    Mastroianni, Timothy
    Grundfest, Warren
    Nishikawa, Kiisa
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 4658 - 4661
  • [4] TENDON REFLEX AND STRATEGIES FOR QUANTIFICATION, WITH NOVEL METHODS INCORPORATING WIRELESS ACCELEROMETER REFLEX QUANTIFICATION DEVICES, A PERSPECTIVE REVIEW
    Lemoyne, Robert
    Mastroianni, Timothy
    Coroian, Cristian
    Grundfest, Warren
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2011, 11 (03) : 471 - 513
  • [5] Quantified reflex strategy using an iPod as a wireless accelerometer application
    LeMoyne, Robert
    Mastroianni, Timothy
    Grundfest, Warren
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2476 - 2479
  • [6] FOURTH GENERATION WIRELESS REFLEX QUANTIFICATION SYSTEM FOR ACQUIRING TENDON REFLEX RESPONSE AND LATENCY
    Lemoyne, Robert
    Mastroianni, Timothy
    Kale, Halo
    Luna, Jorge
    Stewart, Joshua
    Elliot, Stephen
    Bryan, Filip
    Coroian, Cristian
    Grundfest, Warren
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2011, 11 (01) : 31 - 54
  • [7] Wireless Gesture Recognition System using MEMS Accelerometer
    Sidek, Othman
    Hadi, Munajat Abdul
    2014 1ST INTERNATIONAL SYMPOSIUM ON TECHNOLOGY MANAGEMENT AND EMERGING TECHNOLOGIES (ISTMET 2014), 2014, : 444 - 447
  • [8] Three-dimensional quantification of free walking using three-axis accelerometer
    Chen, WX
    Kobayashi, T
    Asano, D
    Kaneda, M
    Teshigawara, Y
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 97 - 98
  • [9] Artificial Proprioceptive Reflex Warning Using EMG in Advanced Driving Assistance System
    Hussain, Muhammad Ishfaq
    Rafique, Muhammad Aasim
    Kim, Joonmo
    Jeon, Moongu
    Pedrycz, Witold
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 1635 - 1644
  • [10] EVALUATION OF SENSORY SYSTEM FUNCTION USING REFLEX MODIFICATION OF THE STARTLE RESPONSE
    CROFTON, KM
    SHEETS, LP
    JOURNAL OF THE AMERICAN COLLEGE OF TOXICOLOGY, 1989, 8 (01): : 199 - 211