Intertester and intratester reliability of movement control tests on the hip for patients with hip osteoarthritis

被引:15
|
作者
Lenzlinger-Asprion, Rahel [1 ]
Keller, Niculina [2 ]
Meichtry, Andre [3 ]
Luomajoki, Hannu [3 ]
机构
[1] Hauptstr 41, CH-8363 Bichelsee, Switzerland
[2] Tanne, CH-9573 Littenheid, Switzerland
[3] Zurich Univ Appl Sci, Inst Physiotherapy, Sch Hlth Profess, Technikumstr 71, CH-8401 Winterthur, Switzerland
来源
BMC MUSCULOSKELETAL DISORDERS | 2017年 / 18卷
关键词
Movement control; Hip; Reliability; Assessment; LOW-BACK-PAIN; MUSCLE STRENGTH MEASUREMENTS; SINGLE-LEG SQUAT; INTERRATER RELIABILITY; CLINIMETRIC PROPERTIES; MOTION; CLASSIFICATION; EPIDEMIOLOGY; PERFORMANCE; IMPAIRMENT;
D O I
10.1186/s12891-017-1388-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Hip joint complaints are a problem associated with increasing age and impair the mobility of a large section of the elderly population. Reliable and valid tests are necessary for a thorough investigation of a joint. A fundamental function of the hip joint is movement control and a test of this function forms a part of the standard examination. Until now there have been few scientific studies which specifically investigate the reliability of measurement tests of movement control of the hip joint. The aim of this study was to examine the intratester and intertester reliability of the movement control tests of the hip joint which are in use in current clinical practice. Methods: Sixteen participants with hip joint complaints and 14 without hip joint impairment were recruited. All participants performed five active movement control tests for the hip joint and were video filmed whilst performing these tests. These films formed the basis for the evaluation and were assessed by two independent physiotherapists. For the intertester and intratester reliability calculations specially set weighted kappa values and the calculated percentages were used. Results: The intertester reliability of the five examined movement control tests of the hip joint showed good to almost perfect values (weighted kappa (wk) = 0.56-0.87). The intratester reliability of the more experienced evaluator A was better in regards to the less experienced evaluator B (average wk = 0.62 vs 0.38). Conclusion: The visual evaluation of movement control tests of the hip joint is especially reliable when carried out by an experienced evaluator. 4 out of 5 tests also showed good results for intertester reliability and support their use in clinical practice.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] Intertester and intratester reliability of movement control tests on the hip for patients with hip osteoarthritis
    Rahel Lenzlinger-Asprion
    Niculina Keller
    André Meichtry
    Hannu Luomajoki
    BMC Musculoskeletal Disorders, 18
  • [2] Intertester and intratester reliability of a movement control test battery for patients with knee osteoarthritis and controls
    Kaukinen, P. T.
    Arokoski, J. P.
    Huber, E. O.
    Luomajoki, H. A.
    JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS, 2017, 17 (03) : 197 - 208
  • [3] Intratester and Intertester Reliability of Clinical Tests for the Assessment of Movement Control in Patients with Neck Pain
    Allofs, Jana
    van Baal, Katharina
    Schwarz, Fiona
    Ehrenbrusthoff, Katja
    Hering, Thomas
    PHYSIOSCIENCE, 2018, 14 (01) : 22 - 33
  • [4] Intratester and intertester reliability during the Star Excursion Balance Tests
    Hertel, J
    Miller, SJ
    Denegar, CR
    JOURNAL OF SPORT REHABILITATION, 2000, 9 (02) : 104 - 116
  • [5] Intratester and intertester reliability of the movement system impairment-based classification for patients with knee pain
    Kajbafvala, Mehrnaz
    Ebrahimi-Takamjani, Ismail
    Salavati, Mahyar
    Saeedi, Ahmad
    Pourahmadi, Mohammad Reza
    Ashnagar, Zinat
    Shaterzadeh-Yazdi, Mohammad Jafar
    Amiri, Ali
    MANUAL THERAPY, 2016, 26 : 117 - 124
  • [7] Hip movement pathomechanics of patients with hip osteoarthritis aim at reducing hip joint loading on the osteoarthritic side
    Meyer, Christophe A. G.
    Wesseling, Mariska
    Corten, Kristoff
    Nieuwenhuys, Angela
    Monari, Davide
    Simon, Jean-Pierre
    Jonkers, Ilse
    Desloovere, Kaat
    GAIT & POSTURE, 2018, 59 : 11 - 17
  • [8] Intratester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test
    Brindle, Richard A.
    Ebaugh, David
    Milner, Clare E.
    JOURNAL OF SPORT REHABILITATION, 2018, 27 (03) : 1 - 3
  • [9] RELIABILITY OF COMMON CLINICAL STANDING BALANCE TESTS FOR PEOPLE WITH HIP OSTEOARTHRITIS
    Dobson, F. L.
    Choi, Y.
    Martin, J.
    Bennell, K. L.
    Hinman, R. S.
    OSTEOARTHRITIS AND CARTILAGE, 2014, 22 : S188 - S188
  • [10] Immediate effects of hip mobilization with movement in patients with hip osteoarthritis: A randomised controlled trial
    Beselga, Carlos
    Neto, Francisco
    Alburquerque-Sendin, Francisco
    Hall, Toby
    Oliveira-Campelo, Natalia
    MANUAL THERAPY, 2016, 22 : 80 - 85