Nonlinear modal identification of a steel frame

被引:31
|
作者
Zapico-Valle, J. L. [1 ]
Garcia-Dieguez, M. [1 ]
Alonso-Camblor, R. [1 ]
机构
[1] Univ Oviedo, Dept Construct & Mfg Engn, Gijon 33203, Spain
关键词
Nonparametric identification; Nonlinear modal identification; Asymptotic nonlinear law; Preloaded stiffness; STRUCTURAL DYNAMICS;
D O I
10.1016/j.engstruct.2013.04.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The nonlinear modal identification of a four-storey steel frame is presented in this paper including both the experimental and the analytical aspects. The first two bending modes of the frame were experimentally isolated by a single-point mono-harmonic excitation. The subsequent free decay vibration was measured and used for identification purposes. An original filtering procedure was developed in order to overcome the drawbacks of the common band-pass filters and to enhance the accuracy of the signals. The nonparametric identification of the structure was carried out through an expeditious procedure based on the analysis of the evolution of the apparent frequency and equivalent viscous damping coefficient as a function of the apparent amplitude of the free decay cycles. The results of this identification reveal that the structure is weakly nonlinear in stiffness and strongly nonlinear in damping, while the mode shapes remain linear within the range of measurements. Asymptotic nonlinear laws defined in the modal space where proposed to model both the stiffness and the damping. This is another original contribution in this paper. The proposed nonlinear model was fitted to the experimental data in the time domain. Results were excellent with fitting errors three orders of magnitude lower than those of a pure linear model. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:246 / 259
页数:14
相关论文
共 50 条
  • [1] Nonlinear analysis of a steel frame
    Mehrabian, Ali
    Ali, Tarig
    Haldar, Achintya
    NONLINEAR ANALYSIS-THEORY METHODS & APPLICATIONS, 2009, 71 (12) : E616 - E623
  • [2] Damage detection of steel frame by modal testing
    Prion, HGL
    Ventura, CE
    Rezai, M
    PROCEEDINGS OF THE 14TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I & II, 1996, 2768 : 1430 - 1436
  • [3] Identification of Instantaneous Modal Parameters of a Nonlinear Building via a Gabor-frame-based Approach
    Su, Wei-Chih
    Huang, Chiung-Shiann
    Lien, Ho-Cheng
    PROCEEDINGS OF 2016 INTERNATIONAL CONFERENCE ON APPLIED SYSTEM INNOVATION (ICASI), 2016,
  • [4] Damage detection of a steel-concrete composite frame by a multilevel approach: Experimental measurements and modal identification
    Chellini, Giuseppe
    De Roeck, Guido
    Nardini, Luca
    Salvatore, Walter
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2008, 37 (15): : 1763 - 1783
  • [6] System Identification and Experimental Modal Analysis of a Frame Structure
    Pappalardo, Carmine Maria
    Guida, Domenico
    ENGINEERING LETTERS, 2018, 26 (01) : 56 - 68
  • [7] Damage detection on a steel frame using simulated modal data
    Park, S
    Stubbs, N
    Bolton, RW
    IMAC - PROCEEDINGS OF THE 16TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS 1 AND 2, 1998, 3243 : 616 - 622
  • [8] Modal properties of a steel frame used for seismic evaluation studies
    Ventura, CE
    Prion, HGL
    Black, C
    Rezai, M
    Latendresse, V
    PROCEEDINGS OF THE 15TH INTERNATIONAL MODAL ANALYSIS CONFERENCE - IMAC, VOLS I AND II, 1997, 3089 : 1885 - 1891
  • [9] PROBLEMS OF STEEL CONSTRUCTION MODAL MODELS IDENTIFICATION
    Rusinski, Eugeniusz
    Czmochowski, Jerzy
    Pietrusiak, Damian
    EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY, 2012, 14 (01): : 54 - 61
  • [10] Damage Identification of Bolt Connections in a Steel Frame
    Yang, Jann N.
    Xia, Ye
    Loh, Chin-Hsiung
    JOURNAL OF STRUCTURAL ENGINEERING, 2014, 140 (03)