MC SIMULATION FOR ESTIMATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kV X-RAY TUBE

被引:0
|
作者
Miceli, A.
Thierry, R.
Flisch, A.
Sennhauser, U.
Casali, F.
机构
关键词
Monte Carlo simulation; cone beam computed tomography; scatter;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A Monte Carlo simulation, based on GEANT4, has been developed to compute the contribution of first order, second order, and higher order scattered radiation in a Computed Tomography (CT) system equipped with an industrial 450 kV X-ray tube and an area detector. The validation of simulation against the experimental data showed a good agreement. The amount of scattering produced by several hollow aluminum cylinders was simulated. It is shown that the scatter-to-primary ratio (SPR) is approximately 5% for the aluminum cylinder of outer diameter of 75 mm, 16% for the diameter of 100 mm, 91% for the diameter of 150 mm, and for the diameter of 200 mm it can rise to 230% in the regions corresponding to the maximum path length. Therefore, the scatter from the object significantly affects quantitative accuracy. Furthermore, the background scatter has been experimentally investigated. The results show that the background scatter plays an important rule and has to be reduced using collimators.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 50 条
  • [1] X-ray scatter correction algorithm for 450 KeV cone-beam CT system
    Dept. of Engineering Physics, Tsinghua University, Beijing 100084, China
    Hedianzixue Yu Tance Jishue, 2006, 6 (908-911):
  • [2] Evaluation of scatter mitigation strategies for X-ray cone-beam CT
    Lasio, G.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2288 - 2289
  • [3] Simulation of x-ray images from the planning CT for online correction of scatter in cone-beam CT
    Rit, S.
    Romero, E.
    Oliva, M. Vila
    Brousmiche, S.
    Sarrut, D.
    Letang, J. M.
    Freud, N.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S115 - S115
  • [4] EXPERIMENTAL SCATTER CORRECTION METHODS IN INDUSTRIAL X-RAY CONE-BEAM CT
    Schoerner, K.
    Goldammer, M.
    Stephan, J.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 30A AND 30B, 2011, 1335 : 485 - 492
  • [5] A simple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT
    Siewerdsen, JH
    Daly, MJ
    Bakhtiar, B
    Moseley, DJ
    Richard, S
    Keller, H
    Jaffray, DA
    MEDICAL PHYSICS, 2006, 33 (01) : 187 - 197
  • [6] Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner
    Kwan, ALC
    Boone, JM
    Shah, N
    MEDICAL PHYSICS, 2005, 32 (09) : 2967 - 2975
  • [7] X-ray scatter correction for cone-beam CT using moving blocker array
    Zhu, L
    Strobel, N
    Fahrig, R
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 251 - 258
  • [8] Data consistency-driven scatter kernel optimization for x-ray cone-beam CT
    Kim, Changhwan
    Park, Miran
    Sung, Younghun
    Lee, Jaehak
    Choi, Jiyoung
    Cho, Seungryong
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 5971 - 5994
  • [9] A direct, empirical method for x-ray scatter correction in digital radiography and cone-beam CT
    Siewerdsen, J
    Bakhtiar, B
    Moseley, D
    Richard, S
    Keller, H
    Daly, M
    Jaffray, D
    MEDICAL PHYSICS, 2005, 32 (06) : 2092 - 2093
  • [10] Monte Carlo Simulations of the Effects of Bowtie Filtration on X-Ray Scatter in Cone-Beam CT
    Bootsma, G.
    Verhaegen, F.
    Jaffray, D.
    MEDICAL PHYSICS, 2010, 37 (06)